메뉴 건너뛰기




Volumn 132, Issue 1, 2012, Pages

Comparative investigation of elastic properties in a trabecula using micro-Brillouin scattering and scanning acoustic microscopy

Author keywords

[No Author keywords available]

Indexed keywords

ELASTIC ANISOTROPY; ELASTIC PROPERTIES; MICRO-BRILLOUIN SCATTERING; MICRO-SCALES; SCANNING ACOUSTIC MICROSCOPES; SCANNING ACOUSTIC MICROSCOPY; SPATIAL RESOLUTION; TISSUE STIFFNESS; TWO DIRECTIONS; WAVE VELOCITY;

EID: 84863648667     PISSN: 00014966     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.4730329     Document Type: Article
Times cited : (18)

References (21)
  • 1
    • 0035857351 scopus 로고    scopus 로고
    • Osteoporosis prevention, diagnosis, and therapy
    • NIH Consensus Development Panel on Osteoporosis Prevention, Diagnosis, and Therapy
    • NIH Consensus Development Panel on Osteoporosis Prevention, Diagnosis, and Therapy, Osteoporosis prevention, diagnosis, and therapy., J. Am. Med. Assoc. 285, 785-795 (2001).
    • (2001) J. Am. Med. Assoc. , vol.285 , pp. 785-795
  • 2
    • 0034510062 scopus 로고    scopus 로고
    • Micromechanical testing of bone trabeculae-potentials and limitations
    • E. Lucchinetti, D. Thomann, and G. Danuser, Micromechanical testing of bone trabeculae-potentials and limitations., J. Mater. Sci. 35, 6057-6064 (2000).
    • (2000) J. Mater. Sci. , vol.35 , pp. 6057-6064
    • Lucchinetti, E.1    Thomann, D.2    Danuser, G.3
  • 4
    • 0027277009 scopus 로고
    • Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction
    • W. J. Landis, M. J. Song, A. Leith, L. McEwen, and B. F. McEwen, Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction., J. Struct. Biol. 110, 39-54 (1993).
    • (1993) J. Struct. Biol. , vol.110 , pp. 39-54
    • Landis, W.J.1    Song, M.J.2    Leith, A.3    McEwen, L.4    McEwen, B.F.5
  • 7
    • 81255127525 scopus 로고    scopus 로고
    • Principal stiffness orientation and degree of anisotropy of human osteons based on nanoindentation in three distinct planes
    • A. G. Reisinger, D. H. Pahr, and P. K. Zysset, Principal stiffness orientation and degree of anisotropy of human osteons based on nanoindentation in three distinct planes., J. Mech. Behav. Biomed. Mater. 4, 2113-2127 (2011).
    • (2011) J. Mech. Behav. Biomed. Mater. , vol.4 , pp. 2113-2127
    • Reisinger, A.G.1    Pahr, D.H.2    Zysset, P.K.3
  • 8
    • 0033213750 scopus 로고    scopus 로고
    • Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur
    • P. K. Zysset, X. E. Guo, C. E. Hoffler, K. E. Moore, and S. A. Goldstein, Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur., J. Biomech. 32, 1005-1012 (1999).
    • (1999) J. Biomech. , vol.32 , pp. 1005-1012
    • Zysset, P.K.1    Guo, X.E.2    Hoffler, C.E.3    Moore, K.E.4    Goldstein, S.A.5
  • 9
    • 8444242203 scopus 로고    scopus 로고
    • Frequency and resolution dependence of the anisotropic impedance estimation in cortical bone using time-resolved scanning acoustic microscopy
    • K. Raum, J. Reibhauer, and J. Brandt, Frequency and resolution dependence of the anisotropic impedance estimation in cortical bone using time-resolved scanning acoustic microscopy., J. Biomed. Mater. Res. Part A 71, 430-438 (2004).
    • (2004) J. Biomed. Mater. Res. Part A , vol.71 , pp. 430-438
    • Raum, K.1    Reibhauer, J.2    Brandt, J.3
  • 10
    • 72049116046 scopus 로고    scopus 로고
    • Assessment of microelastic properties of bone using scanning acoustic microscopy; A face-to-face comparison with nanoindentation
    • F. Rupin, A. Saïed, D. Dalmas, F. Peyrin, S. Haupert, K. Raum, E. Barthel, G. Boivin, and P. Laugier, Assessment of microelastic properties of bone using scanning acoustic microscopy; a face-to-face comparison with nanoindentation., Jpn. J. Appl. Phys. 48, 07GK01 (2009).
    • (2009) Jpn. J. Appl. Phys. , vol.48
    • Rupin, F.1    Saïed, A.2    Dalmas, D.3    Peyrin, F.4    Haupert, S.5    Raum, K.6    Barthel, E.7    Boivin, G.8    Laugier, P.9
  • 12
    • 77956567941 scopus 로고    scopus 로고
    • Measurement of wave velocity distribution in a trabecula by micro Brillouin scattering
    • M. Kawabe, M. Matsukawa, and N. Ohtori, Measurement of wave velocity distribution in a trabecula by micro Brillouin scattering., Jpn. J. Appl. Phys. 49, 07HB05 (2010).
    • (2010) Jpn. J. Appl. Phys. , vol.49
    • Kawabe, M.1    Matsukawa, M.2    Ohtori, N.3
  • 13
    • 77953222631 scopus 로고    scopus 로고
    • Adaptive remodeling of trabecular bone core cultured in 3-D bioreactor providing cyclic loading: An acoustic microscopy study
    • F. Rupin, D. Bossis, L. Vico, F. Peyrin, K. Raum, P. Laugier, and A. Saïed, Adaptive remodeling of trabecular bone core cultured in 3-D bioreactor providing cyclic loading: an acoustic microscopy study., Ultrasound Med. Biol. 36, 999-1007 (2010).
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 999-1007
    • Rupin, F.1    Bossis, D.2    Vico, L.3    Peyrin, F.4    Raum, K.5    Laugier, P.6    Saïed, A.7
  • 16
    • 33845711848 scopus 로고    scopus 로고
    • Application of Brillouin scattering to the local anisotropy and birefringence measurements of thin layers
    • M. Matsukawa, K. Shintani, S. Tomohiro, and N. Ohtori, Application of Brillouin scattering to the local anisotropy and birefringence measurements of thin layers., Ultrasonics (Suppl) 44, e1555-e1559 (2006).
    • (2006) Ultrasonics (Suppl) , vol.44
    • Matsukawa, M.1    Shintani, K.2    Tomohiro, S.3    Ohtori, N.4
  • 17
    • 0032493538 scopus 로고    scopus 로고
    • A new Brillouin scattering techniques for the investigation of acoustic and opto-acoustic properties: Application to polymers
    • J. K. Krüger, J. Embs, J. Brierley, and R. Jiménez, A new Brillouin scattering techniques for the investigation of acoustic and opto-acoustic properties: Application to polymers., J. Phys. D 31, 1913-1917 (1998).
    • (1998) J. Phys. D , vol.31 , pp. 1913-1917
    • Krüger, J.K.1    Embs, J.2    Brierley, J.3    Jiménez, R.4
  • 18
    • 31344442016 scopus 로고    scopus 로고
    • Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation μcT
    • K. Raum, I. Leguerney, F. Chandelier, M. Talmant, A. Saïed, F. Peyrin, and P. Laugier, Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation μcT., Phys. Med. Biol. 51, 733-746 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , pp. 733-746
    • Raum, K.1    Leguerney, I.2    Chandelier, F.3    Talmant, M.4    Saïed, A.5    Peyrin, F.6    Laugier, P.7
  • 19
    • 39249083146 scopus 로고    scopus 로고
    • Correlation between hydroxyapatite crystallite orientation and ultrasonic wave velocities in bovine cortical bone
    • Y. Yamato, M. Matsukawa, T. Yanagitani, K. Yamazaki, H. Mizukawa, and A. Nagano, Correlation between hydroxyapatite crystallite orientation and ultrasonic wave velocities in bovine cortical bone., Calcif. Tissue Int. 82, 162-169 (2008).
    • (2008) Calcif. Tissue Int. , vol.82 , pp. 162-169
    • Yamato, Y.1    Matsukawa, M.2    Yanagitani, T.3    Yamazaki, K.4    Mizukawa, H.5    Nagano, A.6
  • 20
    • 34247379372 scopus 로고    scopus 로고
    • Two-dimensional quantitative analysis of preferential alignment of BAp c-axis for isolated human trabecular bone using microbeam X-ray diffractometer with a transmission optical system
    • S. Miyabe, T. Nakano, T. Ishimoto, N. Takano, T. Adachi, H. Iwaki, A. Kobayashi, K. Takaoka, and Y. Umakoshi, Two-dimensional quantitative analysis of preferential alignment of BAp c-axis for isolated human trabecular bone using microbeam X-ray diffractometer with a transmission optical system., Mater. Trans. 48, 343-347 (2007).
    • (2007) Mater. Trans. , vol.48 , pp. 343-347
    • Miyabe, S.1    Nakano, T.2    Ishimoto, T.3    Takano, N.4    Adachi, T.5    Iwaki, H.6    Kobayashi, A.7    Takaoka, K.8    Umakoshi, Y.9
  • 21
    • 0033119284 scopus 로고    scopus 로고
    • Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
    • I. Rho, M. Roy, T. Tsui, and G. M. Pharr, Elastic properties of microstructural components of human bone tissue as measured by nanoindentation., J. Biomed. Mater. Res. 45, 48-54 (1999).
    • (1999) J. Biomed. Mater. Res. , vol.45 , pp. 48-54
    • Rho, I.1    Roy, M.2    Tsui, T.3    Pharr, G.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.