메뉴 건너뛰기




Volumn 158, Issue 3, 2012, Pages 455-457

The edge vascular response following implantation of a fully bioresorbable device: 'A miss always counts'

Author keywords

Edge vascular response; Geographical miss; Restenosis

Indexed keywords

EVEROLIMUS;

EID: 84863627141     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2012.05.023     Document Type: Article
Times cited : (5)

References (7)
  • 1
    • 0034602842 scopus 로고    scopus 로고
    • I like the candy, i hate the wrapper: The (32)p radioactive stent
    • P.W. Serruys, and I.P. Kay I like the candy, I hate the wrapper: the (32)p radioactive stent Circulation 101 2000 3 7
    • (2000) Circulation , vol.101 , pp. 3-7
    • Serruys, P.W.1    Kay, I.P.2
  • 2
    • 84863616159 scopus 로고    scopus 로고
    • Comparison of edge vascular response after sirolimus- and paclitaxel-eluting stent implantation
    • [Electronic publication ahead of print]
    • W.C. Kang, Y.M. Park, and K.C. Shin Comparison of edge vascular response after sirolimus- and paclitaxel-eluting stent implantation Int J Cardiol 2011 Sep 6 [Electronic publication ahead of print]
    • (2011) Int J Cardiol
    • Kang, W.C.1    Park, Y.M.2    Shin, K.C.3
  • 3
    • 84862904152 scopus 로고    scopus 로고
    • Vascular response of the segments adjacent to the proximal and distal edges of the ABSORB everolimus eluting bioresorbable vascular scaffold: 6 months and 1 year follow-up assessment. A virtual histology intravascular ultrasound study from the first in man, ABSORB Cohort B Trial
    • in press
    • Gogas BD, Serruys PW, Diletti R. Vascular response of the segments adjacent to the proximal and distal edges of the ABSORB everolimus eluting bioresorbable vascular scaffold: 6 months and 1 year follow-up assessment. A virtual histology intravascular ultrasound study from the first In man, ABSORB Cohort B Trial. JACC Cardiovasc Interv in press.
    • JACC Cardiovasc Interv
    • Gogas, B.D.1    Serruys, P.W.2    Diletti, R.3
  • 4
    • 44749083836 scopus 로고    scopus 로고
    • Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial)
    • M.A. Costa, D.J. Angiolillo, and M. Tannenbaum Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial) Am J Cardiol 101 2008 1704 1711
    • (2008) Am J Cardiol , vol.101 , pp. 1704-1711
    • Costa, M.A.1    Angiolillo, D.J.2    Tannenbaum, M.3
  • 5
    • 28844463350 scopus 로고    scopus 로고
    • Vascular response to sirolimus-eluting stents delivered with a nonaggressive implantation technique: Comparison of intravascular ultrasound results from the multicenter, randomized e-sirius, and sirius trials
    • R. Hoffmann, G. Guagliumi, and G. Musumeci Vascular response to sirolimus-eluting stents delivered with a nonaggressive implantation technique: comparison of intravascular ultrasound results from the multicenter, randomized e-sirius, and sirius trials Catheter Cardiovasc Interv 66 2005 499 506
    • (2005) Catheter Cardiovasc Interv , vol.66 , pp. 499-506
    • Hoffmann, R.1    Guagliumi, G.2    Musumeci, G.3
  • 6
    • 85027939362 scopus 로고    scopus 로고
    • Evaluation with in vivo optical coherence tomography and histology of the vascular effects of the everolimus-eluting bioresorbable vascular scaffold at two years following implantation in a healthy porcine coronary artery model: Implications of pilot results for future pre-clinical studies
    • B.D. Gogas, M. Radu, and Y. Onuma Evaluation with in vivo optical coherence tomography and histology of the vascular effects of the everolimus-eluting bioresorbable vascular scaffold at two years following implantation in a healthy porcine coronary artery model: implications of pilot results for future pre-clinical studies Int J Cardiovasc Imaging 28 3 2012 499 511
    • (2012) Int J Cardiovasc Imaging , vol.28 , Issue.3 , pp. 499-511
    • Gogas, B.D.1    Radu, M.2    Onuma, Y.3
  • 7
    • 81855227637 scopus 로고    scopus 로고
    • Statement on authorship and publishing ethics in the international journal of cardiology
    • A.J. Coats, and L.G. Shewan Statement on authorship and publishing ethics in the international journal of cardiology Int J Cardiol 153 2011 239 240
    • (2011) Int J Cardiol , vol.153 , pp. 239-240
    • Coats, A.J.1    Shewan, L.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.