메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4104-4107

Quantification of isolated muscle compartment activity in extrinsic finger muscles for potential prosthesis control sites

Author keywords

[No Author keywords available]

Indexed keywords

COMMAND INTERFACES; CONTROL SITES; CROSS CORRELATIONS; ELECTROMYOGRAPHIC SIGNAL; EMG SIGNAL; FINGER MUSCLES; MEASURED SIGNALS; MUSCLE ACTIVITIES; PROSTHESIS CONTROL; PROSTHETIC HANDS; RESIDUAL LIMB; SURFACE ELECTRODE;

EID: 84863565888     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091019     Document Type: Conference Paper
Times cited : (5)

References (13)
  • 1
    • 60549084435 scopus 로고    scopus 로고
    • Control of limb prostheses
    • D. G. Smith, J. W. Michael and J. H. Bowker eds. 3rd ed., Rosemont, IL: American Academy of Orthopaedic Surgeons
    • D.S. Childress and R.F.f. Weir, "Control of Limb Prostheses," in Atlas of Amputations and Limb Deficiencies, D. G. Smith, J. W. Michael and J. H. Bowker eds. 3rd ed., Rosemont, IL: American Academy of Orthopaedic Surgeons, 2004, pp. 173-195.
    • (2004) Atlas of Amputations and Limb Deficiencies , pp. 173-195
    • Childress, D.S.1    Weir, R.F.F.2
  • 4
    • 1642588281 scopus 로고    scopus 로고
    • The MANUS-HAND dextrous robotics upper limb prosthesis: Mechanical and manipulation aspects
    • Mar
    • J.L. Pons, E. Rocon, R. Ceres, D. Reynaerts, B. Saro, S. Levin, and W. Van Moorleghem, "The MANUS-HAND dextrous robotics upper limb prosthesis: Mechanical and manipulation aspects," Autonomous Robots, vol. 16, (no. 2), pp. 143-163, Mar 2004.
    • (2004) Autonomous Robots , vol.16 , Issue.2 , pp. 143-163
    • Pons, J.L.1    Rocon, E.2    Ceres, R.3    Reynaerts, D.4    Saro, B.5    Levin, S.6    Van Moorleghem, W.7
  • 7
    • 0031395432 scopus 로고    scopus 로고
    • A generic morphological model of a muscle group - Application to the muscles of the forearm
    • J. Leijnse, "A generic morphological model of a muscle group - Application to the muscles of the forearm," Acta Anatomica, vol. 160, (no. 2), pp. 100-111, 1997.
    • (1997) Acta Anatomica , vol.160 , Issue.2 , pp. 100-111
    • Leijnse, J.1
  • 8
    • 55249119066 scopus 로고    scopus 로고
    • Anatomic basis for individuated surface EMG and homogeneous electrostimulation with neuroprostheses of the extensor digitorum communis
    • Jul
    • J. Leijnse, S. Carter, A. Gupta, and S. McCabe, "Anatomic basis for individuated surface EMG and homogeneous electrostimulation with neuroprostheses of the extensor digitorum communis," Journal of Neurophysiology, vol. 100, (no. 1), pp. 64-75, Jul 2008.
    • (2008) Journal of Neurophysiology , vol.100 , Issue.1 , pp. 64-75
    • Leijnse, J.1    Carter, S.2    Gupta, A.3    McCabe, S.4
  • 9
    • 1542271600 scopus 로고    scopus 로고
    • Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work
    • Book Implantable myoelectric sensors (IMES) for upper-extremity prosthesis controlpreliminary work, Editor ed.eds., City Vol.2
    • R.F. Weir, P.R. Troyk, G. DeMichele, and T. Kuiken, "Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work," in Book Implantable myoelectric sensors (IMES) for upper-extremity prosthesis controlpreliminary work, vol. 2, Series Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work, Editor ed.eds., City, 2003, pp. 1562-1565 Vol.2.
    • (2003) Series Implantable Myoelectric Sensors (IMES) for Upper-extremity Prosthesis Control- Preliminary Work , vol.2 , pp. 1562-1565
    • Weir, R.F.1    Troyk, P.R.2    Demichele, G.3    Kuiken, T.4
  • 11
    • 4143087195 scopus 로고    scopus 로고
    • Patterns of muscle activity underlying object-specific grasp by the Macaque monkey
    • Sep
    • T. Brochier, R.L. Spinks, M.A. Umilta, and R.N. Lemon, "Patterns of muscle activity underlying object-specific grasp by the Macaque monkey," Journal of Neurophysiology, vol. 92, (no. 3), pp. 1770-1782, Sep 2004.
    • (2004) Journal of Neurophysiology , vol.92 , Issue.3 , pp. 1770-1782
    • Brochier, T.1    Spinks, R.L.2    Umilta, M.A.3    Lemon, R.N.4
  • 12
    • 34247366472 scopus 로고    scopus 로고
    • A comparison of surface and intramuscular myoelectric signal classification
    • May
    • L.J. Hargrove, K. Englehart, and B. Hudgins, "A comparison of surface and intramuscular myoelectric signal classification," Ieee Transactions on Biomedical Engineering, vol. 54, (no. 5), pp. 847-853, May 2007.
    • (2007) Ieee Transactions on Biomedical Engineering , vol.54 , Issue.5 , pp. 847-853
    • Hargrove, L.J.1    Englehart, K.2    Hudgins, B.3
  • 13
    • 38549167045 scopus 로고    scopus 로고
    • Modulation of muscle synergy recruitment in primate grasping
    • Jan
    • S.A. Overduin, A. d'Avella, J. Roh, and E. Bizzi, "Modulation of muscle synergy recruitment in primate grasping," Journal of Neuroscience, vol. 28, (no. 4), pp. 880-892, Jan 2008.
    • (2008) Journal of Neuroscience , vol.28 , Issue.4 , pp. 880-892
    • Overduin, S.A.1    D'Avella, A.2    Roh, J.3    Bizzi, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.