메뉴 건너뛰기




Volumn , Issue , 2012, Pages 169-175

Implementing an FPGA system for real-time intent recognition for prosthetic legs

Author keywords

embedded system; field programmable gate array (FPGA); neural machine interface; prosthetic leg

Indexed keywords

COMPUTING ENGINES; CYBER PHYSICAL SYSTEMS (CPSS); FAST DECODING; FPGA DEVICES; HUMAN SUBJECTS; INPUT SIGNAL; INTENT RECOGNITION; LOCOMOTION MODE; LOWER LIMB; MICROCONTROLLER UNIT; NEURAL SIGNALS; NEUROMUSCULAR CONTROL; PROSTHETIC LEG; REAL-TIME EXPERIMENT;

EID: 84863552528     PISSN: 0738100X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/2228360.2228394     Document Type: Conference Paper
Times cited : (14)

References (13)
  • 1
    • 77955599340 scopus 로고    scopus 로고
    • A New Control Method for Power-Assisted Wheelchair Based on the Surface Myoelectric Signal
    • Oonishi, Y., Oh, S., and Hori, Y., "A New Control Method for Power-Assisted Wheelchair Based on the Surface Myoelectric Signal," Industrial Electronics, IEEE Transactions on, vol. 57, pp. 3191-3196, 2010.
    • (2010) Industrial Electronics, IEEE Transactions on , vol.57 , pp. 3191-3196
    • Oonishi, Y.1    Oh, S.2    Hori, Y.3
  • 4
    • 0042664129 scopus 로고    scopus 로고
    • A robust, real-time control scheme for multifunction myoelectric control
    • Jul
    • Englehart, K. and Hudgins, B., "A robust, real-time control scheme for multifunction myoelectric control," IEEE Trans Biomed Eng, vol. 50, pp. 848-54, Jul 2003.
    • (2003) IEEE Trans Biomed Eng , vol.50 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 6
    • 33644694014 scopus 로고    scopus 로고
    • Targeted reinnervation for improved prosthetic function
    • Feb
    • Kuiken, T., "Targeted reinnervation for improved prosthetic function," Phys Med Rehabil Clin N Am, vol. 17, pp. 1-13, Feb 2006.
    • (2006) Phys Med Rehabil Clin N Am , vol.17 , pp. 1-13
    • Kuiken, T.1
  • 7
    • 39349093468 scopus 로고    scopus 로고
    • An analysis of EMG electrode configuration for targeted muscle reinnervation based neural machine interface
    • Feb
    • Huang, H., Zhou, P., Li, G., and Kuiken, T. A., "An analysis of EMG electrode configuration for targeted muscle reinnervation based neural machine interface," IEEE Trans Neural Syst Rehabil Eng, vol. 16, pp. 37-45, Feb 2008.
    • (2008) IEEE Trans Neural Syst Rehabil Eng , vol.16 , pp. 37-45
    • Huang, H.1    Zhou, P.2    Li, G.3    Kuiken, T.A.4
  • 8
    • 60549118041 scopus 로고    scopus 로고
    • A strategy for identifying locomotion modes using surface electromyography
    • Jan
    • Huang, H., Kuiken, T. A., and Lipschutz, R. D., "A strategy for identifying locomotion modes using surface electromyography," IEEE Trans Biomed Eng, vol. 56, pp. 65-73, Jan 2009.
    • (2009) IEEE Trans Biomed Eng , vol.56 , pp. 65-73
    • Huang, H.1    Kuiken, T.A.2    Lipschutz, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.