메뉴 건너뛰기




Volumn 39, Issue 6, 2012, Pages 3253-3261

Online database of clinical MR and ultrasound images of brain tumors

Author keywords

brain tumors; intraoperative ultrasound; MRI; online database; registration; validation

Indexed keywords

BRAIN; BRAIN MAPPING; DATABASE SYSTEMS; IMAGE ACQUISITION; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; MAGNETISM; NEUROLOGY; TUMORS; ULTRASONIC IMAGING;

EID: 84863520771     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4709600     Document Type: Article
Times cited : (110)

References (40)
  • 1
    • 62549113870 scopus 로고    scopus 로고
    • Simulation of brain tumors in MR images for evaluation of segmentation efficacy
    • 10.1016/j.media.2008.11.002
    • M. Prastawa, E. Bullitt, and G. Gerig, Simulation of brain tumors in MR images for evaluation of segmentation efficacy., Med. Image Anal. 13 (2), 297-311 (2009). 10.1016/j.media.2008.11.002
    • (2009) Med. Image Anal. , vol.13 , Issue.2 , pp. 297-311
    • Prastawa, M.1    Bullitt, E.2    Gerig, G.3
  • 2
    • 21544432712 scopus 로고    scopus 로고
    • Brainweb: Online interface to a 3D MRI simulated brain database
    • (4)
    • C. Cocosco, V. Kollokian, R.-S. Kwan, and A. Evans, Brainweb: online interface to a 3D MRI simulated brain database., NeuroImage 5 (4) S425 (1997).
    • (1997) NeuroImage , vol.5 , pp. 425
    • Cocosco, C.1    Kollokian, V.2    Kwan, R.-S.3    Evans, A.4
  • 3
    • 0032081266 scopus 로고    scopus 로고
    • Design and construction of a realistic digital brain phantom
    • 10.1109/42.712135
    • D. L. Collins, Design and construction of a realistic digital brain phantom., IEEE Trans. Med. Imaging 17 (3), 463-468 (1998). 10.1109/42.712135
    • (1998) IEEE Trans. Med. Imaging , vol.17 , Issue.3 , pp. 463-468
    • Collins, D.L.1
  • 4
    • 84862644389 scopus 로고    scopus 로고
    • An anthropomorphic polyvinyl alcohol triple-modality brain phantom based on Colin27
    • in, edited by T. Jiang (Springer, Berlin/Heidelberg)
    • S. Chen, An anthropomorphic polyvinyl alcohol triple-modality brain phantom based on Colin27., in Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010, edited by, T. Jiang, (Springer, Berlin/Heidelberg, 2010), pp. 92-100.
    • (2010) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010 , pp. 92-100
    • Chen, S.1
  • 5
    • 84874198466 scopus 로고    scopus 로고
    • The Internet Brain Segmentation Repository (IBSR), Available from: http://www.cma.mgh.harvard.edu/ibsr/
    • The Internet Brain Segmentation Repository (IBSR), Available from: http://www.cma.mgh.harvard.edu/ibsr/.
  • 6
    • 37849038012 scopus 로고    scopus 로고
    • Construction of a 3D probabilistic atlas of human cortical structures
    • 10.1016/j.neuroimage.2007.09.031
    • D. W. Shattuck, Construction of a 3D probabilistic atlas of human cortical structures., Neuroimage 39 (3), 1064-1080 (2008). 10.1016/j.neuroimage. 2007.09.031
    • (2008) Neuroimage , vol.39 , Issue.3 , pp. 1064-1080
    • Shattuck, D.W.1
  • 7
    • 84874206170 scopus 로고    scopus 로고
    • BrainMap, Available from
    • BrainMap, Available from: http://brainmap.org/.
  • 8
    • 32644441220 scopus 로고    scopus 로고
    • The NIH MRI study of normal brain development
    • 10.1016/j.neuroimage.2005.09.068
    • A. C. Evans, The NIH MRI study of normal brain development., Neuroimage 30 (1), 184-202 (2006). 10.1016/j.neuroimage.2005.09.068
    • (2006) Neuroimage , vol.30 , Issue.1 , pp. 184-202
    • Evans, A.C.1
  • 10
    • 31544443575 scopus 로고    scopus 로고
    • The Alzheimer's disease neuroimaging initiative
    • 10.1016/j.nic.2005.09.008
    • S. G. Mueller, The Alzheimer's disease neuroimaging initiative., Neuroimaging Clin N. Am. 15 (4), 869-877 (2005). 10.1016/j.nic.2005.09.008
    • (2005) Neuroimaging Clin N. Am. , vol.15 , Issue.4 , pp. 869-877
    • Mueller, S.G.1
  • 11
    • 34548409688 scopus 로고    scopus 로고
    • Open Access Series of Imaging Studies (OASIS): Cross-sectional MRI data in young, middle aged, nondemented, and demented older adults
    • 10.1162/jocn.2007.19.9.1498
    • D. S. Marcus, Open Access Series of Imaging Studies (OASIS): Cross-sectional MRI data in young, middle aged, nondemented, and demented older adults., J. Cognit. Neurosci. 19 (9), 1498-1507 (2007). 10.1162/jocn.2007.19.9. 1498
    • (2007) J. Cognit. Neurosci. , vol.19 , Issue.9 , pp. 1498-1507
    • Marcus, D.S.1
  • 12
    • 34548409688 scopus 로고    scopus 로고
    • Open Access Series of Imaging Studies (OASIS): Cross-Sectional MRI data in young, middle aged, nondemented, and demented older adults
    • 10.1162/jocn.2007.19.9.1498
    • D. Marcus, Open Access Series of Imaging Studies (OASIS): Cross-Sectional MRI data in young, middle aged, nondemented, and demented older adults., J. Cognit. Neurosci. 19, 1498-1507 (2010). 10.1162/jocn.2007.19.9.1498
    • (2010) J. Cognit. Neurosci. , vol.19 , pp. 1498-1507
    • Marcus, D.1
  • 13
    • 0001059981 scopus 로고    scopus 로고
    • The MINC file format:from bytes to brains
    • P. Neelin, The MINC file format:from bytes to brains., Neuroimage 7 (4), S786 (1998).
    • (1998) Neuroimage , vol.7 , Issue.4 , pp. 786
    • Neelin, P.1
  • 14
    • 79960559000 scopus 로고    scopus 로고
    • New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: System description and validation
    • 10.1007/s11548-010-0535-3
    • L. Mercier, New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: System description and validation., Int. J. Comput. Assist. Radiol. Surg. 6 (4), 507-522 (2011). 10.1007/s11548-010-0535-3
    • (2011) Int. J. Comput. Assist. Radiol. Surg. , vol.6 , Issue.4 , pp. 507-522
    • Mercier, L.1
  • 15
    • 0003057655 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • (Springer, Cambridge, UK), Lecture Notes in Computer Science
    • D. G. Gobbi, R. M. Comeau, and T. M. Peters, Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift., in MICCAI 1999. (Springer, Cambridge, UK, 1999), Lecture Notes in Computer Science.
    • (1999) MICCAI 1999
    • Gobbi, D.G.1    Comeau, R.M.2    Peters, T.M.3
  • 16
    • 34347269185 scopus 로고    scopus 로고
    • Freehand 3D ultrasound reconstruction algorithms-A review
    • 10.1016/j.ultrasmedbio.2007.02.015
    • O. V. Solberg, Freehand 3D ultrasound reconstruction algorithms-A review., Ultrasound Med. Biol. 33, 991-1009 (2007). 10.1016/j.ultrasmedbio.2007. 02.015
    • (2007) Ultrasound Med. Biol. , vol.33 , pp. 991-1009
    • Solberg, O.V.1
  • 17
    • 0021965114 scopus 로고
    • Tumors of the central nervous system studied by computed tomography and ultrasound
    • D. R. Enzmann, Tumors of the central nervous system studied by computed tomography and ultrasound., Radiology 154 (2), 393-399 (1985).
    • (1985) Radiology , vol.154 , Issue.2 , pp. 393-399
    • Enzmann, D.R.1
  • 18
    • 0028039881 scopus 로고
    • A comparison between preoperative magnetic resonance and intraoperative ultrasound tumor volumes and margins
    • 10.1002/jcu.1870220107
    • P. D. Le Roux, A comparison between preoperative magnetic resonance and intraoperative ultrasound tumor volumes and margins., J. Clin. Ultrasound 22 (1), 29-36 (1994). 10.1002/jcu.1870220107
    • (1994) J. Clin. Ultrasound , vol.22 , Issue.1 , pp. 29-36
    • Le Roux, P.D.1
  • 19
    • 85027240635 scopus 로고    scopus 로고
    • Experience using intraoperative 3D ultrasound in conjunction with preoperative MRI in brain tumor surgery
    • in, Montreal, Canada
    • L. Mercier, Experience using intraoperative 3D ultrasound in conjunction with preoperative MRI in brain tumor surgery.. in 5th Annual Scientific Meeting of the Society for Neuro-Oncology, 2010, Montreal, Canada.
    • (2010) 5th Annual Scientific Meeting of the Society for Neuro-Oncology
    • Mercier, L.1
  • 20
    • 0022592563 scopus 로고
    • Brain gliomas: Sonographic characterization
    • J. P. McGahan, Brain gliomas: Sonographic characterization., Radiology 159 (2), 485-492 (1986).
    • (1986) Radiology , vol.159 , Issue.2 , pp. 485-492
    • McGahan, J.P.1
  • 21
    • 84857636452 scopus 로고    scopus 로고
    • Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    • 10.1007/s11548-011-0620-2
    • L. Mercier, Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery., Int. J. Comput. Assist. Radiol. Surg. 7 (1), 125-136 (2012). 10.1007/s11548-011-0620-2
    • (2012) Int. J. Comput. Assist. Radiol. Surg. , vol.7 , Issue.1 , pp. 125-136
    • Mercier, L.1
  • 22
    • 0028287162 scopus 로고
    • Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
    • 10.1097/00004728-199403000-00005
    • D. L. Collins, Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space., J. Comput. Assist. Tomogr. 18 (2), 192-205 (1994). 10.1097/00004728-199403000-00005
    • (1994) J. Comput. Assist. Tomogr. , vol.18 , Issue.2 , pp. 192-205
    • Collins, D.L.1
  • 24
    • 0034496477 scopus 로고    scopus 로고
    • 3D spatial compounding of ultrasound images using image-based nonrigid registration
    • 10.1016/S0301-5629(00)00286-6
    • J. F. Krucker, 3D spatial compounding of ultrasound images using image-based nonrigid registration., Ultrasound Med. Biol. 26 (9), 1475-1488 (2000). 10.1016/S0301-5629(00)00286-6
    • (2000) Ultrasound Med. Biol. , vol.26 , Issue.9 , pp. 1475-1488
    • Krucker, J.F.1
  • 25
    • 33644832997 scopus 로고    scopus 로고
    • Three-dimensional extended field-of-view ultrasound
    • 10.1016/j.ultrasmedbio.2005.11.003
    • T. C. Poon and R. N. Rohling, Three-dimensional extended field-of-view ultrasound., Ultrasound Med. Biol. 32 (3), 357-369 (2006). 10.1016/j. ultrasmedbio.2005.11.003
    • (2006) Ultrasound Med. Biol. , vol.32 , Issue.3 , pp. 357-369
    • Poon, T.C.1    Rohling, R.N.2
  • 26
    • 0031107438 scopus 로고    scopus 로고
    • Three-dimensional spatial compounding of ultrasound images
    • 10.1016/S1361-8415(97)85009-8
    • R. N. Rohling, A. H. Gee, and L. Berman, Three-dimensional spatial compounding of ultrasound images., Med. Image Anal. 1 (3), 177-193 (1997). 10.1016/S1361-8415(97)85009-8
    • (1997) Med. Image Anal. , vol.1 , Issue.3 , pp. 177-193
    • Rohling, R.N.1    Gee, A.H.2    Berman, L.3
  • 27
    • 84857629840 scopus 로고    scopus 로고
    • Rigid registration of 3D ultrasound and MRI: Comparing two approaches on nine tumor cas
    • (Springer, Montreal, Canada)
    • L. Mercier, Rigid registration of 3D ultrasound and MRI: Comparing two approaches on nine tumor cas., in CIM Symposium on Brain, Body and Machine, 2010 (Springer, Montreal, Canada, 2010).
    • (2010) CIM Symposium on Brain, Body and Machine, 2010
    • Mercier, L.1
  • 28
    • 84857636452 scopus 로고    scopus 로고
    • Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    • 10.1007/s11548-011-0620-2
    • L. Mercier, Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery., Int. J. Comput. Assist. Radiol. Surg. 7, 125-136 (2012). 10.1007/s11548-011- 0620-2
    • (2012) Int. J. Comput. Assist. Radiol. Surg. , vol.7 , pp. 125-136
    • Mercier, L.1
  • 29
    • 84863706674 scopus 로고    scopus 로고
    • Hierarchical multimodal image registration based on adaptive local mutual information
    • in, edited by T. Jiang (Springer, Berlin/Heidelberg)
    • D. De Nigris, Hierarchical multimodal image registration based on adaptive local mutual information., in Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010, edited by, T. Jiang, (Springer, Berlin/Heidelberg, 2010), pp. 643-651.
    • (2010) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010 , pp. 643-651
    • De Nigris, D.1
  • 30
    • 52949109750 scopus 로고    scopus 로고
    • Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery
    • 10.1118/1.2977728
    • S. Ji, Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery., Med. Phys. 35 (10), 4612-4624 (2008). 10.1118/1.2977728
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4612-4624
    • Ji, S.1
  • 31
    • 0035487023 scopus 로고    scopus 로고
    • Rigid registration of 3-D ultrasound with MR images: A new approach combining intensity and gradient information
    • 10.1109/42.959301
    • A. Roche, Rigid registration of 3-D ultrasound with MR images: A new approach combining intensity and gradient information., IEEE Trans. Med. Imaging 20 (10), 1038-1049 (2001). 10.1109/42.959301
    • (2001) IEEE Trans. Med. Imaging , vol.20 , Issue.10 , pp. 1038-1049
    • Roche, A.1
  • 33
    • 33947180020 scopus 로고    scopus 로고
    • Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery
    • 10.1016/j.neuroimage.2006.11.060
    • N. Archip, Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery., Neuroimage 35 (2), 609-624 (2007). 10.1016/j.neuroimage.2006.11.060
    • (2007) Neuroimage , vol.35 , Issue.2 , pp. 609-624
    • Archip, N.1
  • 34
    • 65349179708 scopus 로고    scopus 로고
    • Semiautomatic registration of pre- and post brain tumor resection laser range data: Method and validation
    • 10.1109/TBME.2008.2006758
    • S. Ding, Semiautomatic registration of pre- and post brain tumor resection laser range data: Method and validation., IEEE Trans. Biomed. Eng. 56 (3), 770-780 (2009). 10.1109/TBME.2008.2006758
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.3 , pp. 770-780
    • Ding, S.1
  • 35
    • 70349337619 scopus 로고    scopus 로고
    • A non-rigid registration framework that accommodates resection and retraction
    • in, 10.1007/978-3-642-02498-6
    • P. Risholm, A non-rigid registration framework that accommodates resection and retraction., in Inf Process Med Imaging IPMI, 21, 447-458 (2009). 10.1007/978-3-642-02498-6
    • (2009) Inf Process Med Imaging IPMI , vol.21 , pp. 447-458
    • Risholm, P.1
  • 36
    • 27744441182 scopus 로고    scopus 로고
    • Robust nonrigid registration to capture brain shift from intraoperative MRI
    • 10.1109/TMI.2005.856734
    • O. Clatz, Robust nonrigid registration to capture brain shift from intraoperative MRI., IEEE Trans. Med. Imaging 24 (11), 1417-1427 (2005). 10.1109/TMI.2005.856734
    • (2005) IEEE Trans. Med. Imaging , vol.24 , Issue.11 , pp. 1417-1427
    • Clatz, O.1
  • 37
    • 80055045923 scopus 로고    scopus 로고
    • Non-rigid registration with missing correspondences in preoperative and postresection brain images
    • in, edited by T. Jiang (Springer, Berlin/Heidelberg)
    • N. Chitphakdithai and J. Duncan, Non-rigid registration with missing correspondences in preoperative and postresection brain images., in Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010, edited by, T. Jiang, (Springer, Berlin/Heidelberg, 2010), pp. 367-374.
    • (2010) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2010 , pp. 367-374
    • Chitphakdithai, N.1    Duncan, J.2
  • 38
    • 45549085729 scopus 로고    scopus 로고
    • Volume reconstruction of freehand three-dimensional ultrasound using median filters
    • 10.1016/j.ultras.2007.11.005
    • Q. H. Huang and Y. P. Zheng,:Volume reconstruction of freehand three-dimensional ultrasound using median filters., Ultrasonics 48 (3), 182-192 (2008). 10.1016/j.ultras.2007.11.005
    • (2008) Ultrasonics , vol.48 , Issue.3 , pp. 182-192
    • Huang, Q.H.1    Zheng, Y.P.2
  • 39
    • 35448965502 scopus 로고    scopus 로고
    • Probe trajectory interpolation for 3D reconstruction of freehand ultrasound
    • 10.1016/j.media.2007.05.002
    • P. Coupe, Probe trajectory interpolation for 3D reconstruction of freehand ultrasound., Med. Image Anal. 11, 604-615 (2007). 10.1016/j.media.2007. 05.002
    • (2007) Med. Image Anal. , vol.11 , pp. 604-615
    • Coupe, P.1
  • 40
    • 84874215117 scopus 로고    scopus 로고
    • http://www.bic.mni.mcgill.ca/BITE.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.