메뉴 건너뛰기




Volumn 21, Issue 2, 2012, Pages 129-131

Is there a real future for liver elastography?

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC RADIATION FORCE IMPULSE; ACOUSTICS; ALCOHOL LIVER DISEASE; ASCITES; B SCAN; CHRONIC HEPATITIS; CHRONIC LIVER DISEASE; CLINICAL PRACTICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE COURSE; DISEASE SEVERITY; EDITORIAL; ELASTICITY; ELASTOGRAPHY; GOLD STANDARD; HEPATITIS B; HEPATITIS C; HISTOLOGY; HUMAN; INTERMETHOD COMPARISON; LIVER BIOPSY; LIVER CIRRHOSIS; LIVER DISEASE; LIVER FIBROSIS; MAGNETIC RESONANCE ELASTOGRAPHY; MEDICAL TECHNOLOGY; META ANALYSIS (TOPIC); METHODOLOGY; NON INVASIVE PROCEDURE; NONALCOHOLIC FATTY LIVER; NUCLEAR MAGNETIC RESONANCE IMAGING; OBESITY; PREDICTIVE VALUE; QUANTITATIVE ANALYSIS; REAL TIME ELASTOGRAPHY; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SENSIBILITY; SHEAR STRESS; SHEAR WAVE ELASTOGRAPHY; ULTRASOUND; VIRTUAL REALITY;

EID: 84863476615     PISSN: 18418724     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Editorial
Times cited : (10)

References (17)
  • 1
    • 34748845382 scopus 로고    scopus 로고
    • Ultrasound-based transient elastography for the detection of hepatic fibrosis: Systematic review and meta-analysis
    • Talwalkar JA, Kurtz DM, Schoenleber SJ, West CP, Montori VM. Ultrasound-based transient elastography for the detection of hepatic fibrosis: systematic review and meta-analysis. Clin Gastroenterol Hepatol 2007; 5: 1214-1220.
    • (2007) Clin Gastroenterol Hepatol , vol.5 , pp. 1214-1220
    • Talwalkar, J.A.1    Kurtz, D.M.2    Schoenleber, S.J.3    West, C.P.4    Montori, V.M.5
  • 2
    • 41349094999 scopus 로고    scopus 로고
    • Performance of transient elastography for the staging of liver fibrosis: A meta-analysis
    • Friedrich-Rust M, Ong MF, Martens S, et al. Performance of transient elastography for the staging of liver fibrosis: a meta-analysis. Gastroenterology 2008; 134: 960-974.
    • (2008) Gastroenterology , vol.134 , pp. 960-974
    • Friedrich-Rust, M.1    Ong, M.F.2    Martens, S.3
  • 3
    • 77950619459 scopus 로고    scopus 로고
    • Pitfalls of liver stiffness measurement: A 5-years prospective study of 13,369 examinations
    • Castera L, Foucher J, Bernard PH, et al. Pitfalls of liver stiffness measurement: a 5-years prospective study of 13,369 examinations. Hepatology 2010;51:828-835.
    • (2010) Hepatology , vol.51 , pp. 828-835
    • Castera, L.1    Foucher, J.2    Bernard, P.H.3
  • 4
    • 78049511411 scopus 로고    scopus 로고
    • Liver stiffness measurements in patients with HBV vs HCV chronic hepatitis: A comparative study
    • Sporea I, Sirli R, Deleanu A, et al. Liver stiffness measurements in patients with HBV vs HCV chronic hepatitis: a comparative study. World J Gastroenterol 2010;16:4832-4837.
    • (2010) World J Gastroenterol , vol.16 , pp. 4832-4837
    • Sporea, I.1    Sirli, R.2    Deleanu, A.3
  • 5
    • 34748861747 scopus 로고    scopus 로고
    • Assessment of hepatic fibrosis with magnetic resonance elastography
    • Yin M, Talwalkar JA, Glaser KJ, et al. Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterology 2007;5:1207-1213.
    • (2007) Clin Gastroenterology , vol.5 , pp. 1207-1213
    • Yin, M.1    Talwalkar, J.A.2    Glaser, K.J.3
  • 6
    • 46049100990 scopus 로고    scopus 로고
    • Magnetic resonance elastography for the noninvasive staging of liver fibrosis
    • Huwart L, Sempoux C, Vicaut E, et al. Magnetic resonance elastography for the noninvasive staging of liver fibrosis. Gastroenterology 2008; 135: 32-40.
    • (2008) Gastroenterology , vol.135 , pp. 32-40
    • Huwart, L.1    Sempoux, C.2    Vicaut, E.3
  • 7
    • 82655184130 scopus 로고    scopus 로고
    • Real-time tissue elasticity imaging using the combined autocorrelation method
    • Shiina T, Yamakava M, Nitta N, Ueno E. Real-time tissue elasticity imaging using the combined autocorrelation method. Medix suppl 2007; 4-7.
    • (2007) Medix Suppl , pp. 4-7
    • Shiina, T.1    Yamakava, M.2    Nitta, N.3    Ueno, E.4
  • 8
    • 33847202224 scopus 로고    scopus 로고
    • Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis
    • Friedrich-Rust M, Ong MF, Herrmann E, et al. Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis. AJR Am J Roentgenol 2007; 188: 758-764.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 758-764
    • Friedrich-Rust, M.1    Ong, M.F.2    Herrmann, E.3
  • 9
    • 79952357912 scopus 로고    scopus 로고
    • Liver fibrosis in patients with chronic hepatitis C: Noninvasive diagnosis by means of real time tissue elastography-establishment of the method for measurement
    • Koizumi Y, Hirooka M, Kisaka Y, et al. Liver fibrosis in patients with chronic hepatitis C: noninvasive diagnosis by means of real time tissue elastography-establishment of the method for measurement. Radiology 2011; 258:610-617.
    • (2011) Radiology , vol.258 , pp. 610-617
    • Koizumi, Y.1    Hirooka, M.2    Kisaka, Y.3
  • 10
    • 84855549120 scopus 로고    scopus 로고
    • Real-time Elastography witha novel quantitative technology for assessment of liver fibrosis in chronic hepatitis B
    • Wang J, Guo L, Shi X, Pan W, Bai Y, Ai H. Real-time Elastography witha novel quantitative technology for assessment of liver fibrosis in chronic hepatitis B. Eur J Radiol 2012;81:e31-36.
    • (2012) Eur J Radiol , vol.81
    • Wang, J.1    Guo, L.2    Shi, X.3    Pan, W.4    Bai, Y.5    Ai, H.6
  • 11
    • 0036218695 scopus 로고    scopus 로고
    • Acoustic radiation force impulse imaging: In vivo demonstration of clinical feasibility
    • Nightingale K, Soo MS, Nightingale R, Trahey G. Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. Ultrasound Med Biol 2002;28: 227-235.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 227-235
    • Nightingale, K.1    Soo, M.S.2    Nightingale, R.3    Trahey, G.4
  • 12
    • 78751515404 scopus 로고    scopus 로고
    • Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies
    • Sporea I, Sirli RL, Deleanu A, et al. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies. Ultraschall Med 2011; 32 Suppl 1:S46-52.
    • (2011) Ultraschall Med , vol.32 , Issue.SUPPL. 1
    • Sporea, I.1    Sirli, R.L.2    Deleanu, A.3
  • 13
    • 84863096025 scopus 로고    scopus 로고
    • Is ARFI elastography reliable for predicting fibrosis severity in chronic HCV hepatitis?
    • Sporea I, Sirli R, Bota S, et al. Is ARFI elastography reliable for predicting fibrosis severity in chronic HCV hepatitis? World J Radiol 2011; 28; 3:188-193.
    • (2011) World J Radiol , vol.28 , Issue.3 , pp. 188-193
    • Sporea, I.1    Sirli, R.2    Bota, S.3
  • 14
    • 84855835833 scopus 로고    scopus 로고
    • Performance of Acoustic Radiation Force Impulse-Imaging for the staging of liver fibrosis: A pooled meta-analysis
    • Friedrich-Rust M, Nierhoff J, Lupsor M, et al. Performance of Acoustic Radiation Force Impulse-Imaging for the staging of liver fibrosis: a pooled meta-analysis. J Viral Hepat 2012;19:e212-e219.
    • (2012) J Viral Hepat , vol.19
    • Friedrich-Rust, M.1    Nierhoff, J.2    Lupsor, M.3
  • 15
    • 75349088230 scopus 로고    scopus 로고
    • Prospective comparison of two algorithms combining non invasive tests for staging of fibrosis in chronic hepatitis C
    • Castera L, Sebastiani G, Le Bail B, De Ledinghen V, Couzigou P, Alberti A. Prospective comparison of two algorithms combining non invasive tests for staging of fibrosis in chronic hepatitis C. J Hepatol 2010;52:191-198.
    • (2010) J Hepatol , vol.52 , pp. 191-198
    • Castera, L.1    Sebastiani, G.2    Le Bail, B.3    De Ledinghen, V.4    Couzigou, P.5    Alberti, A.6
  • 16
    • 80053912735 scopus 로고    scopus 로고
    • Is it better to use two elastographic methods for liver fibrosis assessment?
    • Sporea I, Şirli R, Popescu A, et al: Is it better to use two elastographic methods for liver fibrosis assessment? World J Gastroenterol 2011; 17: 3824-3829.
    • (2011) World J Gastroenterol , vol.17 , pp. 3824-3829
    • Sporea, I.1    Şirli, R.2    Popescu, A.3
  • 17
    • 33646258022 scopus 로고    scopus 로고
    • A systematic review of the quality of liver biopsy specimens
    • Cholongitas E, Senzolo M, Standish R, et al. A systematic review of the quality of liver biopsy specimens. Am J Clin Pathol 2006;125:710-721.
    • (2006) Am J Clin Pathol , vol.125 , pp. 710-721
    • Cholongitas, E.1    Senzolo, M.2    Standish, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.