Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
-
17599673 10.1016/j.hrthm.2007.03.041
-
RG Hauser LM Kallinen AK Almquist CC Gornick WT Katsiyiannis 2007 Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead Heart Rhythm 4 7 892 896 17599673 10.1016/j.hrthm.2007.03.041
-
(2007)
Heart Rhythm
, vol.4
, Issue.7
, pp. 892-896
-
-
Hauser, R.G.1
Kallinen, L.M.2
Almquist, A.K.3
Gornick, C.C.4
Katsiyiannis, W.T.5
-
3
-
-
79751531987
-
Longevity of Sprint Fidelis implantable cardioverter-defibrillator leads and risk factors for failure: Implications for patient management
-
21242478 10.1161/CIRCULATIONAHA.110.975219
-
RG Hauser WH Maisel PA Friedman LM Kallinen AS Mugglin K Kumar, et al. 2011 Longevity of Sprint Fidelis implantable cardioverter-defibrillator leads and risk factors for failure: implications for patient management Circulation 123 4 358 363 21242478 10.1161/CIRCULATIONAHA.110.975219
-
(2011)
Circulation
, vol.123
, Issue.4
, pp. 358-363
-
-
Hauser, R.G.1
Maisel, W.H.2
Friedman, P.A.3
Kallinen, L.M.4
Mugglin, A.S.5
Kumar, K.6
-
4
-
-
64649087022
-
Increasing hazard of Sprint Fidelis implantable cardioverter- defibrillator lead failure
-
19285920 10.1016/j.hrthm.2009.02.024
-
RG Hauser DL Hayes 2009 Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure Heart Rhythm 6 5 605 610 19285920 10.1016/j.hrthm.2009.02.024
-
(2009)
Heart Rhythm
, vol.6
, Issue.5
, pp. 605-610
-
-
Hauser, R.G.1
Hayes, D.L.2
-
5
-
-
53049105768
-
Accelerating risk of Fidelis lead fracture
-
18783996 10.1016/j.hrthm.2008.06.024
-
D Farwell MS Green R Lemery MH Gollob DH Birnie 2008 Accelerating risk of Fidelis lead fracture Heart Rhythm 5 10 1375 1379 18783996 10.1016/j.hrthm. 2008.06.024
-
(2008)
Heart Rhythm
, vol.5
, Issue.10
, pp. 1375-1379
-
-
Farwell, D.1
Green, M.S.2
Lemery, R.3
Gollob, M.H.4
Birnie, D.H.5
-
6
-
-
72049119342
-
Time-dependent risk of Fidelis lead failure
-
20102898 10.1016/j.amjcard.2009.08.655
-
BA Faulknier DM Traub MK Aktas A Aguila S Rosero JP Daubert, et al. 2010 Time-dependent risk of Fidelis lead failure The American Journal of Cardiology 105 1 95 99 20102898 10.1016/j.amjcard.2009.08.655
-
(2010)
The American Journal of Cardiology
, vol.105
, Issue.1
, pp. 95-99
-
-
Faulknier, B.A.1
Traub, D.M.2
Aktas, M.K.3
Aguila, A.4
Rosero, S.5
Daubert, J.P.6
-
7
-
-
37549062565
-
Sprint Fidelis 6949 high-voltage lead appears to be prone to early failure
-
18053772 10.1016/j.hrthm.2007.09.005
-
A Rao J Wright J Waktare D Todd 2008 Sprint Fidelis 6949 high-voltage lead appears to be prone to early failure Heart Rhythm 5 1 167 18053772 10.1016/j.hrthm.2007.09.005
-
(2008)
Heart Rhythm
, vol.5
, Issue.1
, pp. 167
-
-
Rao, A.1
Wright, J.2
Waktare, J.3
Todd, D.4
-
8
-
-
37549068476
-
The higher than expected early failure rate of the Sprint Fidelis implantable cardioverter defibrillator lead (model 6949, Medtronic, Inc.)
-
18277394 10.1016/j.hrthm.2007.10.028 author reply 168
-
A Catanchin L Anderson S Jones D Ward 2008 The higher than expected early failure rate of the Sprint Fidelis implantable cardioverter defibrillator lead (model 6949, Medtronic, Inc.) Heart Rhythm 5 1 167 168 18277394 10.1016/j.hrthm.2007.10.028 author reply 168
-
(2008)
Heart Rhythm
, vol.5
, Issue.1
, pp. 167-168
-
-
Catanchin, A.1
Anderson, L.2
Jones, S.3
Ward, D.4
-
9
-
-
77955711102
-
Right-sided implantation and subpectoral position are predisposing factors for Fidelis lead fractures (abstr.)
-
Bernstein N.E.K.E.; Wong B.; et al. (2009). Right-sided implantation and subpectoral position are predisposing factors for Fidelis lead fractures (abstr.). Heart Rhythm, 6(1).
-
(2009)
Heart Rhythm
, vol.6
, Issue.1
-
-
Bernstein, N.E.K.E.1
Wong, B.2
-
10
-
-
84873823354
-
-
Accessed 25 Oct 2001
-
Sprint Fidelis® Model 6949 Lead Performance. Available at: http://www.medtronic.com/product-advisories/physician/sprint-fidelis/ 6949-LEAD-PERFORMANCE. Accessed 25 Oct 2001.
-
Sprint Fidelis® Model 6949 Lead Performance
-
-
-
11
-
-
42649141945
-
Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: A report from the Canadian Heart Rhythm Society Device Advisory Committee
-
18452862 10.1016/j.hrthm.2008.01.029
-
AD Krahn J Champagne JS Healey D Cameron CS Simpson B Thibault, et al. 2008 Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: a report from the Canadian Heart Rhythm Society Device Advisory Committee Heart Rhythm 5 5 639 642 18452862 10.1016/j.hrthm.2008.01.029
-
(2008)
Heart Rhythm
, vol.5
, Issue.5
, pp. 639-642
-
-
Krahn, A.D.1
Champagne, J.2
Healey, J.S.3
Cameron, D.4
Simpson, C.S.5
Thibault, B.6
-
12
-
-
84863409354
-
Survival analysis of a high-voltage implantable cardioverter- defibrillator lead on US Food and Drug Administration recall [abstract]
-
EHD Keung R Jesse 2010 Survival analysis of a high-voltage implantable cardioverter-defibrillator lead on US Food and Drug Administration recall [abstract] Heart Rhythm 7 5
-
(2010)
Heart Rhythm
, vol.7
, pp. 5
-
-
Keung, E.H.D.1
Jesse, R.2
-
13
-
-
34250750358
-
Lead failures: Dealing with even less perfect
-
17599674 10.1016/j.hrthm.2007.05.002
-
BL Wilkoff 2007 Lead failures: dealing with even less perfect Heart Rhythm 4 7 897 899 17599674 10.1016/j.hrthm.2007.05.002
-
(2007)
Heart Rhythm
, vol.4
, Issue.7
, pp. 897-899
-
-
Wilkoff, B.L.1
-
14
-
-
77952587743
-
Risk factors for implantable defibrillator lead fracture in a recalled and a nonrecalled lead
-
20082653 10.1111/j.1540-8167.2009.01683.x
-
TB Morrison RF Rea DO Hodge D Crusan C Koestler SJ Asirvatham, et al. 2010 Risk factors for implantable defibrillator lead fracture in a recalled and a nonrecalled lead Journal of Cardiovascular Electrophysiology 21 6 671 677 20082653 10.1111/j.1540-8167.2009.01683.x
-
(2010)
Journal of Cardiovascular Electrophysiology
, vol.21
, Issue.6
, pp. 671-677
-
-
Morrison, T.B.1
Rea, R.F.2
Hodge, D.O.3
Crusan, D.4
Koestler, C.5
Asirvatham, S.J.6
-
16
-
-
77950505016
-
Predictors of fracture risk of a small caliber implantable cardioverter defibrillator lead
-
19954500 10.1111/j.1540-8159.2009.02626.x
-
AC Ha BZ Vezi A Keren H Alanazi MH Gollob MS Green, et al. 2010 Predictors of fracture risk of a small caliber implantable cardioverter defibrillator lead Pacing and Clinical Electrophysiology 33 4 437 443 19954500 10.1111/j.1540-8159.2009.02626.x
-
(2010)
Pacing and Clinical Electrophysiology
, vol.33
, Issue.4
, pp. 437-443
-
-
Ha, A.C.1
Vezi, B.Z.2
Keren, A.3
Alanazi, H.4
Gollob, M.H.5
Green, M.S.6
-
17
-
-
26844512588
-
The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries
-
16226180 10.1016/j.jacc.2005.04.063
-
SM Al-Khatib FL Lucas JG Jollis DJ Malenka DE Wennberg 2005 The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries Journal of the American College of Cardiology 46 8 1536 1540 16226180 10.1016/j.jacc.2005.04.063
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.8
, pp. 1536-1540
-
-
Al-Khatib, S.M.1
Lucas, F.L.2
Jollis, J.G.3
Malenka, D.J.4
Wennberg, D.E.5
-
18
-
-
63049117133
-
Fatal outcome in a pacemaker-dependent patient
-
19335869 10.1111/j.1540-8159.2009.02320.x
-
M Undavia A Fischer D Mehta 2009 Fatal outcome in a pacemaker-dependent patient Pacing and Clinical Electrophysiology 32 4 550 553 19335869 10.1111/j.1540-8159.2009.02320.x
-
(2009)
Pacing and Clinical Electrophysiology
, vol.32
, Issue.4
, pp. 550-553
-
-
Undavia, M.1
Fischer, A.2
Mehta, D.3
-
19
-
-
78751497776
-
Psychological adjustment in ICD patients living with advisory fidelis leads
-
20731739 10.1111/j.1540-8167.2010.01867.x
-
A Keren SF Sears P Nery J Shaw MS Green R Lemery, et al. 2011 Psychological adjustment in ICD patients living with advisory fidelis leads Journal of Cardiovascular Electrophysiology 22 1 57 63 20731739 10.1111/j.1540-8167.2010.01867.x
-
(2011)
Journal of Cardiovascular Electrophysiology
, vol.22
, Issue.1
, pp. 57-63
-
-
Keren, A.1
Sears, S.F.2
Nery, P.3
Shaw, J.4
Green, M.S.5
Lemery, R.6
-
20
-
-
77956796268
-
Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures
-
20493965 10.1016/j.hrthm.2010.05.015
-
LM Kallinen RG Hauser C Tang DP Melby AK Almquist WT Katsiyiannis, et al. 2010 Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures Heart Rhythm 7 8 1048 1055 20493965 10.1016/j.hrthm.2010.05.015
-
(2010)
Heart Rhythm
, vol.7
, Issue.8
, pp. 1048-1055
-
-
Kallinen, L.M.1
Hauser, R.G.2
Tang, C.3
Melby, D.P.4
Almquist, A.K.5
Katsiyiannis, W.T.6
-
21
-
-
77950504074
-
Implementation of lead safety recommendations
-
10.1111/j.1540-8159.2009.02622.x
-
JB Van Rees CJW Borleffs JJ Bax EM Nagtegaal ET Van Der Velde L Van Erven, et al. 2010 Implementation of lead safety recommendations Pacing and Clinical Electrophysiology 33 4 431 436 10.1111/j.1540-8159.2009.02622.x
-
(2010)
Pacing and Clinical Electrophysiology
, vol.33
, Issue.4
, pp. 431-436
-
-
Van Rees, J.B.1
Borleffs, C.J.W.2
Bax, J.J.3
Nagtegaal, E.M.4
Van Der Velde, E.T.5
Van Erven, L.6
-
22
-
-
77955713825
-
Multicenter experience with extraction of the Sprint Fidelis implantable cardioverter-defibrillator lead
-
20598467 10.1016/j.jacc.2010.03.058
-
M Maytin CJ Love A Fischer RG Carrillo JD Garisto MG Bongiorni, et al. 2010 Multicenter experience with extraction of the Sprint Fidelis implantable cardioverter-defibrillator lead Journal of the American College of Cardiology 56 8 646 650 20598467 10.1016/j.jacc.2010.03.058
-
(2010)
Journal of the American College of Cardiology
, vol.56
, Issue.8
, pp. 646-650
-
-
Maytin, M.1
Love, C.J.2
Fischer, A.3
Carrillo, R.G.4
Garisto, J.D.5
Bongiorni, M.G.6
-
23
-
-
0032873111
-
Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute
-
10527016 10.1111/j.1540-8159.1999.tb00628.x 1:STN:280: DyaK1MvlsVWnsg%3D%3D
-
CL Byrd BL Wilkoff CJ Love TD Sellers KT Turk R Reeves, et al. 1999 Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute Pacing and Clinical Electrophysiology 22 9 1348 1357 10527016 10.1111/j.1540-8159.1999.tb00628.x 1:STN:280:DyaK1MvlsVWnsg%3D%3D
-
(1999)
Pacing and Clinical Electrophysiology
, vol.22
, Issue.9
, pp. 1348-1357
-
-
Byrd, C.L.1
Wilkoff, B.L.2
Love, C.J.3
Sellers, T.D.4
Turk, K.T.5
Reeves, R.6
-
24
-
-
59149100414
-
Predictors of complications of endovascular chronic lead extractions from pacemakers and defibrillators: A single-operator experience
-
18775042 10.1111/j.1540-8167.2008.01283.x
-
SK Agarwal S Kamireddy J Nemec A Voigt S Saba 2009 Predictors of complications of endovascular chronic lead extractions from pacemakers and defibrillators: a single-operator experience Journal of Cardiovascular Electrophysiology 20 2 171 175 18775042 10.1111/j.1540-8167.2008.01283.x
-
(2009)
Journal of Cardiovascular Electrophysiology
, vol.20
, Issue.2
, pp. 171-175
-
-
Agarwal, S.K.1
Kamireddy, S.2
Nemec, J.3
Voigt, A.4
Saba, S.5
|