메뉴 건너뛰기




Volumn 14, Issue , 2012, Pages 849-854

Improved method and case study of ground-coupled heat pump system design

Author keywords

GCHP; GHE; Optimized design; TRNSYS; Underground thermal balance

Indexed keywords

GEOTHERMAL HEAT PUMPS; HEAT EXCHANGERS; HEAT TRANSFER; PUMPS; STRUCTURAL DESIGN;

EID: 84863375919     PISSN: 18766102     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1016/j.egypro.2011.12.887     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 1
    • 71749087828 scopus 로고    scopus 로고
    • Current status of ground-Source heat pumps in China
    • W. Yang, et al. Current status of ground-source heat pumps in China. Energy Policy 38 (2010) 323-332.
    • (2010) Energy Policy , vol.38 , pp. 323-332
    • Yang, W.1
  • 3
    • 35348837853 scopus 로고    scopus 로고
    • Experimental investigation and theoretical model of heat transfer of saturated soil around coaxial ground coupled heat exchanger
    • Zhao, J., Wang, H.J., Li, X.G., Dai, C.S., 2007. Experimental investigation and theoretical model of heat transfer of saturated soil around coaxial ground coupled heat exchanger. Applied Thermal Engineering 28, 116-125.
    • (2007) Applied Thermal Engineering , vol.28 , pp. 116-125
    • Zhao, J.1    Wang, H.J.2    Li, X.G.3    Dai, C.S.4
  • 4
    • 34848878030 scopus 로고    scopus 로고
    • Optimization of thermal performance of a building with ground source heat pump system
    • Zogou O, Stamatelos A. Optimization of thermal performance of a building with ground source heat pump system. Energy Conversion and Management 48 (2007) 2853-2863.
    • (2007) Energy Conversion and Management , vol.48 , pp. 2853-2863
    • Zogou, O.1    Stamatelos, A.2
  • 5
    • 38549096201 scopus 로고    scopus 로고
    • Verification of the energy-Savings effect of the district heating and cooling system-Simulation of an electrical-driven heat pump system
    • T. Nagota, et al., Verification of the energy-savings effect of the district heating and cooling system - simulation of an electrical-driven heat pump system, Energy and Buildings 40 (2008) 732-741.
    • (2008) Energy and Buildings , vol.40 , pp. 732-741
    • Al, T.N.1
  • 6
    • 0036462273 scopus 로고    scopus 로고
    • Ground heat exchanger temperature distribution analysis and experimental verification
    • Y. Bi, L. Chen, C. Wu, Ground heat exchanger temperature distribution analysis and experimental verification, Appl. Thermal Eng. 22 (2) (2002) 183-189.
    • (2002) Appl. Thermal Eng. , vol.22 , Issue.2 , pp. 183-189
    • Bi, Y.1    Chen, L.2    Wu, C.3
  • 7
    • 46449114305 scopus 로고    scopus 로고
    • On the estimation of thermal resistance in borehole thermal conductivity test
    • D. Marcotte, P. Pasquier. On the estimation of thermal resistance in borehole thermal conductivity test. Renewable Energy 33 (2008) 2407-2415.
    • (2008) Renewable Energy , vol.33 , pp. 2407-2415
    • Marcotte, D.1    Pasquier, P.2
  • 8
    • 84901612141 scopus 로고    scopus 로고
    • University of Wisconsin, Madison (USA): Solar Energy Laboratory
    • TRNSYS 17: Transient System Simulation Program, University of Wisconsin, Madison (USA): Solar Energy Laboratory.
    • TRNSYS 17: Transient System Simulation Program
  • 10
    • 77955177157 scopus 로고    scopus 로고
    • Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control
    • C.K. Lee. Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control. Applied Energy 87 (2010) 3507-3513.
    • (2010) Applied Energy , vol.87 , pp. 3507-3513
    • Lee, C.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.