메뉴 건너뛰기




Volumn 47, Issue 4, 2011, Pages 37-41

Influence of moisture content on parameters of return voltage measurement in oil-paper insulation system of transformer

Author keywords

Central time constant; Initial slope; Maximum of RVM; Moisture content; Return voltage measurement(RVM)

Indexed keywords


EID: 84863337864     PISSN: 10011609     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 84863338439 scopus 로고    scopus 로고
    • Temperature influence on parameters of return voltage measurement of oil-paper insulation system in transformer
    • LIU Gang, LIAO Rui-jin, FENG Yun. et al. Temperature influence on parameters of return voltage measurement of oil-paper insulation system in transformer [J]. High Voltage Apparatus, 2010, 46(1): 80-84.
    • (2010) High Voltage Apparatus , vol.46 , Issue.1 , pp. 80-84
    • Liu, G.1    Liao, R.-J.2    Feng, Y.3
  • 2
    • 0026268037 scopus 로고
    • Spectrum of polarization phenomena of long time-constant as a diagnostic method of oil-paper insulation system
    • Japan: IEEE Dielectrics and Electrical Insulation Society and Institute of Electrical Engineers of Japan
    • KALOCSAL L. Spectrum of polarization phenomena of long time-constant as a diagnostic method of oil-paper insulation system [C]//Proceeding of the 3rd International Conference on Properties and Application of Dielectric Materials. Japan: IEEE Dielectrics and Electrical Insulation Society and Institute of Electrical Engineers of Japan, 1991: 723-726.
    • (1991) Proceeding of the 3rd International Conference on Properties and Application of Dielectric Materials , pp. 723-726
    • Kalocsal, L.1
  • 3
    • 0033353280 scopus 로고    scopus 로고
    • Measuring voltage response: A non-destructive diagnostic test method of HV insulation
    • NEMETH E. Measuring voltage response: A non-destructive diagnostic test method of HV insulation[J]. IEEE Proceeding of Science, Measurement and Technology, 1999, 146(5): 249-252.
    • (1999) IEEE Proceeding of Science, Measurement and Technology , vol.146 , Issue.5 , pp. 249-252
    • Nemeth, E.1
  • 4
    • 84863391935 scopus 로고    scopus 로고
    • Moisture content influence on aging rate of oil-paper
    • LIU Min. Moisture content influence on aging rate of oil-paper[J]. Insulation Material, 2008, 41(3): 40-42.
    • (2008) Insulation Material , vol.41 , Issue.3 , pp. 40-42
    • Liu, M.1
  • 5
    • 33645639244 scopus 로고    scopus 로고
    • A new insulation testing methord
    • LI Minghua, DONG Ming, YAN Zhang. A new insulation testing methord[J]. High Voltage Engineering, 2002, 28(8): 43-46.
    • (2002) High Voltage Engineering , vol.28 , Issue.8 , pp. 43-46
    • Li, M.1    Dong, M.2    Yan, Z.3
  • 7
    • 3242802114 scopus 로고    scopus 로고
    • Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurement
    • SAHA T K, PURKAIT P. Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurement [J]. IEEE Transactions on Power Delivery, 2004, 19(3): 1127-1134.
    • (2004) IEEE Transactions on Power Delivery , vol.19 , Issue.3 , pp. 1127-1134
    • Saha, T.K.1    Purkait, P.2
  • 8
    • 79953023479 scopus 로고    scopus 로고
    • The analysis on moisture content in board of oil-paper transformers with polarization spectrum
    • ZHANG Tao, CAI Jin-zhan. The analysis on moisture content in board of oil-paper transformers with polarization spectrum[J]. Advanced Technology of Electrical Engineering and Energy, 2009, 28(4): 46-50.
    • (2009) Advanced Technology of Electrical Engineering and Energy , vol.28 , Issue.4 , pp. 46-50
    • Zhang, T.1    Cai, J.-Z.2
  • 11
    • 0035138230 scopus 로고    scopus 로고
    • Spectroscopic studies of the ageing of cellulosic paper
    • ALI A M E M, HERMAN H, HEYWOOD R J. Spectroscopic studies of the ageing of cellulosic paper[J]. Polymer, 2001 (42): 2893-2900.
    • (2001) Polymer , Issue.42 , pp. 2893-2900
    • Ali, A.M.E.M.1    Herman, H.2    Heywood, R.J.3
  • 12
    • 0037631169 scopus 로고    scopus 로고
    • Using of parameter of RVM measurement of qualitative appreciation of power transformer insulation state
    • Asia: IEEE
    • ASCHENBRENNER V, UCIK T. Using of parameter of RVM measurement of qualitative appreciation of power transformer insulation state [C] // Transmission and Distribution Conference and Exhibition, Asia: IEEE, 2002: 1829-1833.
    • (2002) Transmission and Distribution Conference and Exhibition , pp. 1829-1833
    • Aschenbrenner, V.1    Ucik, T.2
  • 13
    • 0344009281 scopus 로고    scopus 로고
    • Separation of ageing and moisture impacts on transformer insulation degradation by polarization measurements
    • Paris: CIGRE
    • YAO Z T, SAHA T K. Separation of ageing and moisture impacts on transformer insulation degradation by polarization measurements[C]// Proceedings of the CIGRE 2002 Paris Session, Paris: CIGRE, 2002: 26-30.
    • (2002) Proceedings of the CIGRE 2002 Paris Session , pp. 26-30
    • Yao, Z.T.1    Saha, T.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.