메뉴 건너뛰기




Volumn 81, Issue 9, 2012, Pages 1319-1323

Characterization of PE-g-HEMA films prepared by gamma irradiation through nuclear microprobe techniques

Author keywords

Gamma radiation; Graft copolymers; IBA; Polymers for bioapplications

Indexed keywords

ANALYTICAL TECHNIQUES; COPOLYMERIZATION REACTIONS; CYTOTOXIC; GAMMA IRRADIATION; GRAFTING DEGREE; GRAFTING YIELD; HETEROGENEOUS DISTRIBUTIONS; IBA; NATURAL CONTAMINANTS; NUCLEAR MICROPROBES; POLYMERS FOR BIOAPPLICATIONS; QUALITATIVE ANALYSIS; QUANTITATIVE DATA; TOXICOLOGICAL HAZARDS;

EID: 84863315137     PISSN: 0969806X     EISSN: 18790895     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2012.01.045     Document Type: Article
Times cited : (4)

References (8)
  • 2
  • 3
    • 36048944034 scopus 로고    scopus 로고
    • New LDPE copolymeric films with enhanced hydrophilic properties prepared by gamma irradiation
    • Ferreira L.M., Falcão A.N., Gil M.H. New LDPE copolymeric films with enhanced hydrophilic properties prepared by gamma irradiation. Mater. Sci. Forum 2006, 514-516:1034-1038.
    • (2006) Mater. Sci. Forum , pp. 1034-1038
    • Ferreira, L.M.1    Falcão, A.N.2    Gil, M.H.3
  • 4
    • 36049045060 scopus 로고    scopus 로고
    • Elemental and topographic characterization of LDPE based copolymeric films obtained by gamma irradiation
    • Ferreira L.M., Falcão A.N., Gil M.H. Elemental and topographic characterization of LDPE based copolymeric films obtained by gamma irradiation. Nucl. Instrum. Methods Phys. Res. Sect. B 2007, 265:193-197.
    • (2007) Nucl. Instrum. Methods Phys. Res. Sect. B , vol.265 , pp. 193-197
    • Ferreira, L.M.1    Falcão, A.N.2    Gil, M.H.3
  • 5
    • 84863322016 scopus 로고    scopus 로고
    • ISO 10993-5, International Standard: Biological Evaluation of Medical Devices-Part 5: Tests for in vitro Cytotoxicity, 2nd edition.
    • ISO 10993-5, 1999. International Standard: Biological Evaluation of Medical Devices-Part 5: Tests for in vitro Cytotoxicity, 2nd edition.
    • (1999)
  • 6
    • 84863326920 scopus 로고    scopus 로고
    • ISO 10993-1, International Standard: Biological Evaluation of Medical Devices-Part 1: Evaluation and Testing, 3rd edition
    • ISO 10993-1, 2003. International Standard: Biological Evaluation of Medical Devices-Part 1: Evaluation and Testing, 3rd edition.
    • (2003)
  • 8
    • 50849146233 scopus 로고
    • Radiation grafting-state-of-the-art
    • Stannet V.T. Radiation grafting-state-of-the-art. Radiat. Phys. Chem. 1990, 35(1-3):82-87.
    • (1990) Radiat. Phys. Chem. , vol.35 , Issue.1-3 , pp. 82-87
    • Stannet, V.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.