메뉴 건너뛰기




Volumn 36, Issue 3, 2012, Pages

Albumin Dialysis Without Anticoagulation in High-Risk Patients: An Observational Study

Author keywords

Acute liver failure; Albumin dialysis; Anticoagulation; Heparin; Molecular Adsorbent Recirculating System

Indexed keywords

BLOOD; COAGULATION; DIALYSIS; PATIENT TREATMENT; RATS; UREA;

EID: 84863236845     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01065.x     Document Type: Article
Times cited : (13)

References (14)
  • 2
    • 0036873139 scopus 로고    scopus 로고
    • Managing liver failure
    • Kelly DA. Managing liver failure. Postgrad Med J 2002;78:660-7.
    • (2002) Postgrad Med J , vol.78 , pp. 660-667
    • Kelly, D.A.1
  • 3
    • 0034896528 scopus 로고    scopus 로고
    • Results of a phase I trial evaluating a liver support device utilizing albumin dialysis
    • Awad SS, Swanker F, Magee J, Punch J, Bartlett RH. Results of a phase I trial evaluating a liver support device utilizing albumin dialysis. Surgery 2001;130:354-62.
    • (2001) Surgery , vol.130 , pp. 354-362
    • Awad, S.S.1    Swanker, F.2    Magee, J.3    Punch, J.4    Bartlett, R.H.5
  • 4
    • 0032927116 scopus 로고    scopus 로고
    • Molecular adsorbent recirculating system (MARS): clinical results of a new membrane-based blood purification system for bioartificial liver support
    • Stange J, Mitzner SR, Risler T, etal. Molecular adsorbent recirculating system (MARS): clinical results of a new membrane-based blood purification system for bioartificial liver support. Artif Organs 1999;23:319-30.
    • (1999) Artif Organs , vol.23 , pp. 319-330
    • Stange, J.1    Mitzner, S.R.2    Risler, T.3
  • 5
    • 0028268061 scopus 로고
    • Comparison of the use of standard heparin and prostacyclin anticoagulation in spontaneous and pump-driven extracorporeal circuits in patients with combined acute renal and hepatic failure
    • Davenport A, Will EJ, Davison AM. Comparison of the use of standard heparin and prostacyclin anticoagulation in spontaneous and pump-driven extracorporeal circuits in patients with combined acute renal and hepatic failure. Nephron 1994;66:431-7.
    • (1994) Nephron , vol.66 , pp. 431-437
    • Davenport, A.1    Will, E.J.2    Davison, A.M.3
  • 6
    • 0033653649 scopus 로고    scopus 로고
    • Continuous veno-venous hemofiltration without anticoagulation in high-risk patients
    • Tan HK, Baldwin I, Bellomo R. Continuous veno-venous hemofiltration without anticoagulation in high-risk patients. Intensive Care Med 2000;26:1652-7.
    • (2000) Intensive Care Med , vol.26 , pp. 1652-1657
    • Tan, H.K.1    Baldwin, I.2    Bellomo, R.3
  • 7
    • 14944382685 scopus 로고    scopus 로고
    • FVIIa corrects the coagulopathy of fulminant hepatic failure but may be associated with thrombosis: a report of four cases
    • Pavese P, Bonadona A, Beaubien J, etal. FVIIa corrects the coagulopathy of fulminant hepatic failure but may be associated with thrombosis: a report of four cases. Can J Anaesth 2005;52:26-9.
    • (2005) Can J Anaesth , vol.52 , pp. 26-29
    • Pavese, P.1    Bonadona, A.2    Beaubien, J.3
  • 8
    • 33847636826 scopus 로고    scopus 로고
    • Anticoagulation minimization is safe and effective in albumin liver dialysis using the molecular adsorbent recirculating system (MARS)
    • Tan HK, Yang WS, Chow P, Lui HF, Choong HL, Wong KS. Anticoagulation minimization is safe and effective in albumin liver dialysis using the molecular adsorbent recirculating system (MARS). Artif Organs 2007;31:193-9.
    • (2007) Artif Organs , vol.31 , pp. 193-199
    • Tan, H.K.1    Yang, W.S.2    Chow, P.3    Lui, H.F.4    Choong, H.L.5    Wong, K.S.6
  • 9
    • 43549087081 scopus 로고    scopus 로고
    • Albumin dialysis in critically ill patients: use versus omission of intradialytic heparin
    • Yang WS, Tan HK, Lui HF, Chow PK, Choong HL, Wong KS. Albumin dialysis in critically ill patients: use versus omission of intradialytic heparin. Artif Organs 2008;32:411-6.
    • (2008) Artif Organs , vol.32 , pp. 411-416
    • Yang, W.S.1    Tan, H.K.2    Lui, H.F.3    Chow, P.K.4    Choong, H.L.5    Wong, K.S.6
  • 10
    • 56049101618 scopus 로고    scopus 로고
    • The use of regional citrate anticoagulation for continuous venovenous hemodiafiltration in acute kidney injury
    • Durao MS, Monte JC, Batista MC, etal. The use of regional citrate anticoagulation for continuous venovenous hemodiafiltration in acute kidney injury. Crit Care Med 2008;36:3024-9.
    • (2008) Crit Care Med , vol.36 , pp. 3024-3029
    • Durao, M.S.1    Monte, J.C.2    Batista, M.C.3
  • 11
    • 69249166108 scopus 로고    scopus 로고
    • Intraoperative dialysis during liver transplantation with citrate dialysate
    • Epub 2009 Jun 8.
    • Winrow RM, Davis C, Halldorson JB, Ahmad S. Intraoperative dialysis during liver transplantation with citrate dialysate. Hemodial Int 2009;13:257-60. Epub 2009 Jun 8.
    • (2009) Hemodial Int , vol.13 , pp. 257-260
    • Winrow, R.M.1    Davis, C.2    Halldorson, J.B.3    Ahmad, S.4
  • 12
    • 33748808716 scopus 로고    scopus 로고
    • Molecular adsorbent recirculating system and hemostatsis in patients at high risk of bleeding: an observational study
    • Faybik P, Bacher A, Kozek-Langenecker SA, etal. Molecular adsorbent recirculating system and hemostatsis in patients at high risk of bleeding: an observational study. Crit Care 2006;10:R24.
    • (2006) Crit Care , vol.10
    • Faybik, P.1    Bacher, A.2    Kozek-Langenecker, S.A.3
  • 13
    • 24044439501 scopus 로고    scopus 로고
    • Albumin and hydroxyethyl starch 130kDa/0.4 improves filter clearance and haemocompatibility in haemo- and plasmafiltration-an in vitro study
    • Unger JK, Haltern C, Dohmen B, etal. Albumin and hydroxyethyl starch 130kDa/0.4 improves filter clearance and haemocompatibility in haemo- and plasmafiltration-an in vitro study. Nephro Dial Transplant 2005;20:1922-31.
    • (2005) Nephro Dial Transplant , vol.20 , pp. 1922-1931
    • Unger, J.K.1    Haltern, C.2    Dohmen, B.3
  • 14
    • 0034821097 scopus 로고    scopus 로고
    • Safety observations in phase I clinical evaluation of the Excorp Medical Bioartificial Liver Support System after the first four patients
    • Mazariegos GV, Kramer DJ, Lopez RC, etal. Safety observations in phase I clinical evaluation of the Excorp Medical Bioartificial Liver Support System after the first four patients. ASAIO J 2001;47:471-5.
    • (2001) ASAIO J , vol.47 , pp. 471-475
    • Mazariegos, G.V.1    Kramer, D.J.2    Lopez, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.