메뉴 건너뛰기




Volumn 148, Issue 4, 2012, Pages 431-438

Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery

Author keywords

[No Author keywords available]

Indexed keywords

ANTHROPOMETRY; ARTICLE; COMPARATIVE STUDY; COMPUTER PROGRAM; EQUIPMENT DESIGN; FLUOROSCOPY; HUMAN; IMAGE QUALITY; INSTRUMENTATION; METABOLISM; METHODOLOGY; OCCUPATIONAL EXPOSURE; ORTHOPEDICS; RADIATION DOSE; RADIATION PROTECTION; RADIATION SCATTERING; RADIOMETRY; THYROID GLAND; X RAY;

EID: 84863230237     PISSN: 01448420     EISSN: 17423406     Source Type: Journal    
DOI: 10.1093/rpd/ncr149     Document Type: Article
Times cited : (32)

References (20)
  • 1
    • 0018841697 scopus 로고
    • Irradiation of the surgeon during pinning of femoral fractures
    • Giachino, A. A. and Cheng, M. Irradiation of the surgeon during pinning of femoral fractures. J. Bone Joint Surg. Br. 62, 227-229 (1980).
    • (1980) J. Bone Joint Surg. Br. , vol.62 , pp. 227-229
    • Giachino, A.A.1    Cheng, M.2
  • 2
    • 22544432535 scopus 로고    scopus 로고
    • Radiation exposure to the hands from mini C-arm fluoroscopy
    • Singer, G. Radiation exposure to the hands from mini C-arm fluoroscopy. J. Hand Surg. Am. 30, 795-797 (2005).
    • (2005) J. Hand Surg. Am. , vol.30 , pp. 795-797
    • Singer, G.1
  • 3
    • 0032127740 scopus 로고    scopus 로고
    • Ionising radiation during internal fixation of extracapsular neck of femur fratures
    • Giannoudis, P. V., McGuigan, J. and Shaw, D. L. Ionising radiation during internal fixation of extracapsular neck of femur fratures. Injury 29, 469-472 (1998).
    • (1998) Injury , vol.29 , pp. 469-472
    • Giannoudis, P.V.1    McGuigan, J.2    Shaw, D.L.3
  • 5
    • 84863246332 scopus 로고    scopus 로고
    • Medtronic, O-ARM® Complete Multidimensional Surgical Imaging System Technical Guide. Medtronic Navigation
    • Medtronic, O-ARM® Complete Multidimensional Surgical Imaging System Technical Guide. Medtronic Navigation (2007).
    • (2007)
  • 7
    • 73149110471 scopus 로고    scopus 로고
    • Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer
    • Smith-Bindman, R., Lipson, J., Marcus, R., Kim, K.-P., Mahesh, M., Gould, R., de Gonzalez, A. B. and Miglioretti, D. L. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch. Intern. Med. 169(22), 2078-2086 (2009).
    • (2009) Arch. Intern. Med. , vol.169 , Issue.22 , pp. 2078-2086
    • Smith-Bindman, R.1    Lipson, J.2    Marcus, R.3    Kim, K.-P.4    Mahesh, M.5    Gould, R.6    de Gonzalez, A.B.7    Miglioretti, D.L.8
  • 8
    • 84863260305 scopus 로고    scopus 로고
    • Cedars-Sinai radiation overdoses went unseen at several points. Available on, LA Times, 14 October 2009 (accessed 24 November 2010)
    • Zarembo, A. Cedars-Sinai radiation overdoses went unseen at several points. Available on http://articles.latimes.com/2009/oct/14/local/me-cedars-sinai14, LA Times, 14 October 2009 (accessed 24 November 2010).
    • Zarembo, A.1
  • 10
    • 0034667336 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
    • Spine(Phila Pa 1976)
    • Rampersaud, Y. R., Foley, K. T., Shen, A. C., Williams, S. and Solomito, M. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine(Phila Pa 1976) 25, 2637-2645 (2000).
    • (2000) , vol.25 , pp. 2637-2645
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3    Williams, S.4    Solomito, M.5
  • 11
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion Fluoroscopic method versus computerassisted surgery
    • Spine(Phila Pa 1976)
    • Slomczykowski, M., Roberto, M., Schneeberger, P., Ozdoba, C. and Vock, P. Radiation dose for pedicle screw insertion Fluoroscopic method versus computerassisted surgery. Spine(Phila Pa 1976) 24, 975-983 (1999).
    • (1999) , vol.24 , pp. 975-983
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 12
    • 34147127753 scopus 로고    scopus 로고
    • Effect of introduction of mini C-arm image intensifier in orthopaedic theatre
    • White, S. P. Effect of introduction of mini C-arm image intensifier in orthopaedic theatre. Ann. R. Coll. Engl. 89, 368-371 (2007).
    • (2007) Ann. R. Coll. Engl. , vol.89 , pp. 368-371
    • White, S.P.1
  • 13
    • 2342439949 scopus 로고    scopus 로고
    • Radiation protection issues with the use of mini C-arm image intensifiers in surgery of the upper limb. Optimisation of practice and the impact of new regulations
    • Sinha, S., Evans, S. J., Arundell, M. K. and Burke, F. D. Radiation protection issues with the use of mini C-arm image intensifiers in surgery of the upper limb. Optimisation of practice and the impact of new regulations. J. Bone Joint Surg. Br. 86, 333-336 (2004).
    • (2004) J. Bone Joint Surg. Br. , vol.86 , pp. 333-336
    • Sinha, S.1    Evans, S.J.2    Arundell, M.K.3    Burke, F.D.4
  • 14
    • 60549084002 scopus 로고    scopus 로고
    • Patient and surgeon radiation exposure: comparison of standard and mini-C-arm fluoroscopy
    • Giordano, B. D., Baumhauer, J. F., Morgan, T. L. and Rechtine, G. R. II. Patient and surgeon radiation exposure: comparison of standard and mini-C-arm fluoroscopy. J. Bone Joint Surg. Am. 91, 297-304 (2009).
    • (2009) J. Bone Joint Surg. Am. , vol.91 , pp. 297-304
    • Giordano, B.D.1    Baumhauer, J.F.2    Morgan, T.L.3    Rechtine II, G.R.4
  • 15
    • 0030688058 scopus 로고    scopus 로고
    • The breast: in-plane x-ray protection during diagnostic thoracic CT-shielding with bismuth radioprotective garments
    • Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R. and Weaver, J. S. The breast: in-plane x-ray protection during diagnostic thoracic CT-shielding with bismuth radioprotective garments. Radiology 205, 853-858 (1997).
    • (1997) Radiology , vol.205 , pp. 853-858
    • Hopper, K.D.1    King, S.H.2    Lobell, M.E.3    TenHave, T.R.4    Weaver, J.S.5
  • 16
    • 0037305664 scopus 로고    scopus 로고
    • in-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data
    • Fricke, B. L., Donnelly, L. F., Frush, D. P., Yoshizumi, T., Varchena, V., Poe, S.A. and Lucaya, J. in-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data. AJR Am. J. Roentgenol. 180, 407-411 (2003).
    • (2003) AJR Am. J. Roentgenol. , vol.180 , pp. 407-411
    • Fricke, B.L.1    Donnelly, L.F.2    Frush, D.P.3    Yoshizumi, T.4    Varchena, V.5    Poe, S.A.6    Lucaya, J.7
  • 17
    • 33847666024 scopus 로고    scopus 로고
    • CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator
    • Neeman, Z., Dromi, S. A., Sarin, S. and Wood, B. J. CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator. J. Vasc. Interv. Radiol. 17(12), 1999-2004 (2006).
    • (2006) J. Vasc. Interv. Radiol. , vol.17 , Issue.12 , pp. 1999-2004
    • Neeman, Z.1    Dromi, S.A.2    Sarin, S.3    Wood, B.J.4
  • 18
    • 70350061995 scopus 로고    scopus 로고
    • Eye protection in orthopaedic surgery. An in vitro study of various forms of eye protection and their effectiveness
    • Mansour, A. A. III, Even, J. L., Phillips, S. and Halpern, J. L. Eye protection in orthopaedic surgery. An in vitro study of various forms of eye protection and their effectiveness. J. Bone Joint Surg. Am. 91, 1050-1054 (2009).
    • (2009) J. Bone Joint Surg. Am. , vol.91 , pp. 1050-1054
    • Mansour III, A.A.1    Even, J.L.2    Phillips, S.3    Halpern, J.L.4