메뉴 건너뛰기




Volumn 2, Issue 2, 2009, Pages 133-142

Optimization of bathroom ventilation design for an iso class 5 clean ward

Author keywords

Bathroom; Cfd; Clean ward; Contaminant control; Hospital; Ventilation

Indexed keywords


EID: 84863229421     PISSN: 19963599     EISSN: 19968744     Source Type: Journal    
DOI: 10.1007/S12273-009-9310-1     Document Type: Article
Times cited : (28)

References (14)
  • 2
    • 8644263177 scopus 로고    scopus 로고
    • CDC, Atlanta, GA: US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention
    • CDC (2003). Guidelines for Environmental Infection Control in Health-Care Facilities. Atlanta, GA: US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention.
    • (2003) Guidelines for Environmental Infection Control in Health-Care Facilities
  • 3
    • 29144451987 scopus 로고    scopus 로고
    • Modeling particle distribution and deposition in indoor environments with a new drift-flux model
    • Chen F, Yu SCM, Lai ACK (2006). Modeling particle distribution and deposition in indoor environments with a new drift-flux model. Atmospheric Environment, 40: 357-367.
    • (2006) Atmospheric Environment , vol.40 , pp. 357-367
    • Chen, F.1    Yu, S.C.M.2    Lai, A.C.K.3
  • 4
    • 0029390545 scopus 로고
    • Comparison of different k-ε models for indoor air flow computations
    • Chen Q (1995). Comparison of different k-ε models for indoor air flow computations. Numerical Heat Transfer, 28 (B): 353-369.
    • (1995) Numerical Heat Transfer , vol.28 , Issue.B , pp. 353-369
    • Chen, Q.1
  • 5
    • 84863243821 scopus 로고    scopus 로고
    • FLUENT Version 6.2, Fluent Inc., Lebanon, New Hampshire, USA
    • FLUENT Version 6.2 (2005). Fluent Inc., Lebanon, New Hampshire, USA.
    • (2005)
  • 6
    • 84863295509 scopus 로고    scopus 로고
    • GB50073-2001, Beijing: China Plans Press. (in Chinese)
    • GB50073-2001 (2001). Clean Room Design Criterion. Beijing: China Plans Press. (in Chinese)
    • (2001) Clean Room Design Criterion
  • 8
    • 84858048424 scopus 로고    scopus 로고
    • IEST-RP-CC012.2, The Institute of Environmental Sciences and Technology (IEST), IL, USA
    • IEST-RP-CC012.2 (2007). Considerations in Cleanroom Design. The Institute of Environmental Sciences and Technology (IEST), IL, USA.
    • (2007) Considerations in Cleanroom Design
  • 10
    • 0019542559 scopus 로고
    • The value of protective isolation in preventing nosocomial infections in high risk patients
    • Pizzo PA (1981). The value of protective isolation in preventing nosocomial infections in high risk patients. American Journal of Medicine, 70: 631-637.
    • (1981) American Journal of Medicine , vol.70 , pp. 631-637
    • Pizzo, P.A.1
  • 12
    • 0036568496 scopus 로고    scopus 로고
    • Computation of the airflow in a pilot scale clean room using k-ε turbulence models
    • Rouaud O, Havet M (2002). Computation of the airflow in a pilot scale clean room using k-ε turbulence models. International Journal of Refrigeration, 25 (3): 351-361.
    • (2002) International Journal of Refrigeration , vol.25 , Issue.3 , pp. 351-361
    • Rouaud, O.1    Havet, M.2
  • 14
    • 0026804722 scopus 로고
    • Development of turbulence models for shear flows by a double expansion technique
    • Yokhot V, Orzag SA, Thangam S, Gatski TB, Speziale CG (1992). Development of turbulence models for shear flows by a double expansion technique. Physics of Fluids A, 4 (7): 1510-1520.
    • (1992) Physics of Fluids A , vol.4 , Issue.7 , pp. 1510-1520
    • Yokhot, V.1    Orzag, S.A.2    Thangam, S.3    Gatski, T.B.4    Speziale, C.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.