메뉴 건너뛰기




Volumn 48, Issue , 2012, Pages 514-523

Improved load-frequency control contribution of variable speed variable pitch wind generators

Author keywords

De loading; Inertial support; Load frequency control; Wind generator

Indexed keywords

CONTROL STRATEGIES; DE-LOADING; DOUBLY FED INDUCTION GENERATORS; LOAD-FREQUENCY CONTROL; OVERSPEEDING; PERMANENT MAGNET SYNCHRONOUS GENERATOR; SIMULINK; VARIABLE SPEED-VARIABLE PITCHES; VARYING LOAD; WIND GENERATOR SYSTEMS; WIND SPEED;

EID: 84863209304     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2012.05.021     Document Type: Article
Times cited : (76)

References (32)
  • 1
    • 0003524896 scopus 로고    scopus 로고
    • John Wiley, Chichester, T. Burton, D. Sharpe, N. Jenkins, E. Bossanyi (Eds.)
    • Wind energy handbook 2001, John Wiley, Chichester. T. Burton, D. Sharpe, N. Jenkins, E. Bossanyi (Eds.).
    • (2001) Wind energy handbook
  • 2
    • 84864010080 scopus 로고    scopus 로고
    • United Nations framework convention on climate change: Kyoto protocol (available online): [accessed 26.10.09].
    • United Nations framework convention on climate change: Kyoto protocol (available online): [accessed 26.10.09]. http://www.unfccc.int.
  • 3
    • 84864015818 scopus 로고    scopus 로고
    • European Parliament and Council: Directive 2009/28/EC on the promotion of the use of energy from renewable sources and amending and subsequently repealing Directives 2001/77/EC and 2003/30/EC (available online): [accessed 23.04.09].
    • European Parliament and Council: Directive 2009/28/EC on the promotion of the use of energy from renewable sources and amending and subsequently repealing Directives 2001/77/EC and 2003/30/EC (available online): [accessed 23.04.09]. http://eur-lex.europa.eu/.
  • 4
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirements for wind farms
    • Tsili M., Papathanassiou S. A review of grid code technical requirements for wind farms. IET Renewable Power Generation Sept. 2009, 3(3):308-332.
    • (2009) IET Renewable Power Generation , vol.3 , Issue.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2
  • 6
  • 7
    • 84861408123 scopus 로고    scopus 로고
    • Power reserve in interconnected systems with high wind power production
    • Dany G. Power reserve in interconnected systems with high wind power production. 2001 IEEE Power Tech Porto 2001, 4:6-11.
    • (2001) 2001 IEEE Power Tech Porto , vol.4 , pp. 6-11
    • Dany, G.1
  • 8
    • 84864004714 scopus 로고    scopus 로고
    • Elkraft System and Eltra Regulation
    • Draft version TF 3.2.5 wind turbines connected to grids with voltages above 100 kV-technical regulation for th properties and the regulation of wind turbines. Dec.
    • Elkraft System and Eltra Regulation. In: Draft version TF 3.2.5 wind turbines connected to grids with voltages above 100 kV-technical regulation for the properties and the regulation of wind turbines. Dec. 2004.
    • (2004)
  • 11
    • 25144486705 scopus 로고    scopus 로고
    • Grid interaction of offshore wind farms. Part 2. Case study simulations
    • Morren J., Pierik J.T.G., de Haan S.W.H., Bozelie J. Grid interaction of offshore wind farms. Part 2. Case study simulations. Wind Energy 2005, 8(3):279-293.
    • (2005) Wind Energy , vol.8 , Issue.3 , pp. 279-293
    • Morren, J.1    Pierik, J.T.G.2    de Haan, S.W.H.3    Bozelie, J.4
  • 12
    • 10244250325 scopus 로고    scopus 로고
    • Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency
    • Ekanayake J., Jenkins N. Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency. IEEE Transactions on Energy Conversion Dec. 2004, 19(4):800-802.
    • (2004) IEEE Transactions on Energy Conversion , vol.19 , Issue.4 , pp. 800-802
    • Ekanayake, J.1    Jenkins, N.2
  • 14
    • 43849103784 scopus 로고    scopus 로고
    • Temporary primary frequency control support by variable speed wind turbines- potential and applications
    • Ullah N.R., Thiringer T., Karlsson D. Temporary primary frequency control support by variable speed wind turbines- potential and applications. IEEE Transactions on Power Systems May 2008, 23(2):601-612.
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 601-612
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3
  • 16
    • 33646360809 scopus 로고    scopus 로고
    • Optimum generation control in wind parks when carrying out system operator requests
    • de Almeida R.G., Castronuovo E.D., Lopes J.A.P. Optimum generation control in wind parks when carrying out system operator requests. IEEE Transactions on Power Systems May 2006, 21(2):718-725.
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.2 , pp. 718-725
    • de Almeida, R.G.1    Castronuovo, E.D.2    Lopes, J.A.P.3
  • 19
    • 44349104315 scopus 로고    scopus 로고
    • Control of variable speed wind turbines in islanded mode of operation
    • Kanellos F.D., Hatziargyriou N.D. Control of variable speed wind turbines in islanded mode of operation. IEEE Transactions on Energy Conversion June 2008, 23(2):535-543.
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.2 , pp. 535-543
    • Kanellos, F.D.1    Hatziargyriou, N.D.2
  • 20
    • 67650090594 scopus 로고    scopus 로고
    • Variable speed wind generators participation in primary frequency control
    • Courtecuisse V., Robyns B., Francois B., Petit M., Deuse J. Variable speed wind generators participation in primary frequency control. Wind Engineering 2008, 32(3):299-318.
    • (2008) Wind Engineering , vol.32 , Issue.3 , pp. 299-318
    • Courtecuisse, V.1    Robyns, B.2    Francois, B.3    Petit, M.4    Deuse, J.5
  • 21
    • 3342969237 scopus 로고    scopus 로고
    • Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines
    • Holdsworth L., Ekanayake J.B., Jenkins N. Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines. Wind Energy 2004, 7(1):21-35.
    • (2004) Wind Energy , vol.7 , Issue.1 , pp. 21-35
    • Holdsworth, L.1    Ekanayake, J.B.2    Jenkins, N.3
  • 22
    • 43849097550 scopus 로고    scopus 로고
    • Frequency response capability of full converter wind turbine generators in comparison to conventional generation
    • Conroy J.F., Watson R. Frequency response capability of full converter wind turbine generators in comparison to conventional generation. IEEE Transactions on Power Systems May 2008, 23(2):649-656.
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 649-656
    • Conroy, J.F.1    Watson, R.2
  • 24
    • 84889498628 scopus 로고    scopus 로고
    • John Wiley, Chichester, T. Ackermann (Ed.)
    • Wind power in power systems 2005, John Wiley, Chichester. T. Ackermann (Ed.).
    • (2005) Wind power in power systems
  • 28
    • 0004224089 scopus 로고
    • McGraw-Hill, New York, P.C. Krause (Ed.)
    • Analysis of electric machinery 1986, McGraw-Hill, New York. P.C. Krause (Ed.).
    • (1986) Analysis of electric machinery
  • 29
    • 12744262671 scopus 로고    scopus 로고
    • Evaluation of current control methods for wind turbines using doubly-fed induction machines
    • Petersson A., Harnefors L., Thiringer T. Evaluation of current control methods for wind turbines using doubly-fed induction machines. IEEE Transactions on Power Electronics Jan. 2005, 20(1):227-235.
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.1 , pp. 227-235
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 30
    • 20844435606 scopus 로고
    • McGraw-Hill, New York, P. Kundur (Ed.)
    • Power system stability and control 1993, McGraw-Hill, New York. P. Kundur (Ed.).
    • (1993) Power system stability and control
  • 31
    • 24944534558 scopus 로고    scopus 로고
    • The inertial response of induction-machine-based wind turbines
    • Mullane A., O'Malley M. The inertial response of induction-machine-based wind turbines. IEEE Transactions on Power Systems Aug. 2005, 20(3):1496-1503.
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.3 , pp. 1496-1503
    • Mullane, A.1    O'Malley, M.2
  • 32
    • 84928780158 scopus 로고
    • A general simulation algorithm for the accurate assessment of isolated diesel-wind turbines systems interaction. I. A general multimachine power system model
    • Stavrakakis G.S., Kariniotakis G.N. A general simulation algorithm for the accurate assessment of isolated diesel-wind turbines systems interaction. I. A general multimachine power system model. IEEE Transactions on Energy Conversion Sep. 1995, 10(3):577-583.
    • (1995) IEEE Transactions on Energy Conversion , vol.10 , Issue.3 , pp. 577-583
    • Stavrakakis, G.S.1    Kariniotakis, G.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.