메뉴 건너뛰기




Volumn 48, Issue 2, 2012, Pages 819-822

Experimental verification and finite element analysis of short-circuit electromagnetic force for dry-type transformer

Author keywords

Dry type transformer; resultant mechanical force; sequential finite element analysis; short circuit force

Indexed keywords

TIMING CIRCUITS; TRANSFORMER WINDINGS; WINDING;

EID: 84863050891     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2011.2174212     Document Type: Article
Times cited : (150)

References (13)
  • 1
    • 0036493573 scopus 로고    scopus 로고
    • Simulation of forces and 3-D field arising during power autotransformer fault due to electric arc in HV winding
    • Feb.
    • K. Zakrzewski, B. Tomczuk, and D. Koteras, "Simulation of forces and 3-D field arising during power autotransformer fault due to electric arc in HV winding," IEEE Trans. Magn., vol. 38, no. 2, pp. 1153-1156, Feb. 2002.
    • (2002) IEEE Trans. Magn. , vol.38 , Issue.2 , pp. 1153-1156
    • Zakrzewski, K.1    Tomczuk, B.2    Koteras, D.3
  • 2
    • 44349113072 scopus 로고    scopus 로고
    • Transformer connection under no-load and short-circuit events
    • A. I. Lur'e, "Transformer connection under no-load and short-circuit events," Russian Electr. Eng., vol. 79, no. 2, pp. 57-70, 2008.
    • (2008) Russian Electr. Eng. , vol.79 , Issue.2 , pp. 57-70
    • Lur'e, A.I.1
  • 3
    • 84863078101 scopus 로고    scopus 로고
    • Calculations for short circuit withstand capability of a distribution transformer
    • G. P. Peter, "Calculations for short circuit withstand capability of a distribution transformer," Int. J. Adv. Technol., vol. 2, no. 1, pp. 142-150, 2011.
    • (2011) Int. J. Adv. Technol. , vol.2 , Issue.1 , pp. 142-150
    • Peter, G.P.1
  • 4
    • 34147133869 scopus 로고    scopus 로고
    • Analysis of short-circuit performance of split-winding transformer using coupled field-circuit approach
    • Feb.
    • G. B. Kumbhar and S. V. Kulkarni, "Analysis of short-circuit performance of split-winding transformer using coupled field-circuit approach," IEEE Trans. Power Del., vol. 22, no. 2, pp. 936-943, Feb. 2007.
    • (2007) IEEE Trans. Power Del. , vol.22 , Issue.2 , pp. 936-943
    • Kumbhar, G.B.1    Kulkarni, S.V.2
  • 5
    • 42649145850 scopus 로고    scopus 로고
    • Three- and two-dimensional finite-element computation of inrush current and short-circuit electromagnetic forces on windings of a three-phase core-type power transformer
    • May
    • J. Faiz, B. M. Ebrahimi, and T. Noori, "Three- and two-dimensional finite-element computation of inrush current and short-circuit electromagnetic forces on windings of a three-phase core-type power transformer," IEEE Trans. Magn., vol. 44, no. 5, pp. 590-597, May 2008.
    • (2008) IEEE Trans. Magn. , vol.44 , Issue.5 , pp. 590-597
    • Faiz, J.1    Ebrahimi, B.M.2    Noori, T.3
  • 6
    • 79956369903 scopus 로고    scopus 로고
    • Finite element analysis of short circuit electromagnetic force in power transformer
    • Mar.
    • H.-M. Ahn, J.-Y. Lee, J.-K.Kim, S.-Y. Jung,Y.-H.Oh, and S.-C. Hahn, "Finite element analysis of short circuit electromagnetic force in power transformer," IEEE Trans. Ind. Appl., vol. 47, no. 3, pp. 1267-1272, Mar. 2011.
    • (2011) IEEE Trans. Ind. Appl. , vol.47 , Issue.3 , pp. 1267-1272
    • Ahn, H.-M.1    Lee, J.-Y.2    Kim, J.-K.3    Jung, S.-Y.4    Oh, Y.-H.5    Hahn, S.-C.6
  • 8
    • 76249098962 scopus 로고    scopus 로고
    • Experimental characterization of interlamination shorts in transformer cores
    • Feb.
    • C. A. Schulz, D. Roger, S. Duchesne, and J.-N. Vincent, "Experimental characterization of interlamination shorts in transformer cores," IEEE Trans. Magn., vol. 46, no. 2, pp. 614-617, Feb. 2010.
    • (2010) IEEE Trans. Magn. , vol.46 , Issue.2 , pp. 614-617
    • Schulz, C.A.1    Roger, D.2    Duchesne, S.3    Vincent, J.-N.4
  • 10
    • 0035386047 scopus 로고    scopus 로고
    • Computation of inrush current forces on transformer windings
    • Apr.
    • A. A. Adly, "Computation of inrush current forces on transformer windings," IEEE Trans. Magn., vol. 37, no. 4, pp. 2855-2857, Apr. 2001.
    • (2001) IEEE Trans. Magn. , vol.37 , Issue.4 , pp. 2855-2857
    • Adly, A.A.1
  • 11
    • 0036118765 scopus 로고    scopus 로고
    • Instability of the continuously transposed cable under axial short-circuit forces in transformers
    • Jan.
    • R. P. Mukund, "Instability of the continuously transposed cable under axial short-circuit forces in transformers," IEEE Trans. Power Del., vol. 17, no. 1, pp. 149-154, Jan. 2002.
    • (2002) IEEE Trans. Power Del. , vol.17 , Issue.1 , pp. 149-154
    • Mukund, R.P.1
  • 12
  • 13
    • 2342580905 scopus 로고    scopus 로고
    • Numerical simulation of transient force and eddy current loss in a 720-MVApower transformer
    • Feb.
    • S. L. Ho, Y. Li, H. C. Wong, S. H. Wang, and R. Y. Tang, "Numerical simulation of transient force and eddy current loss in a 720-MVApower transformer," IEEE Trans. Magn., vol. 40, no. 2, pp. 687-690, Feb. 2004.
    • (2004) IEEE Trans. Magn. , vol.40 , Issue.2 , pp. 687-690
    • Ho, S.L.1    Li, Y.2    Wong, H.C.3    Wang, S.H.4    Tang, R.Y.5