메뉴 건너뛰기




Volumn , Issue , 2011, Pages 105-108

Automatic detection of the intima-media layer in ultrasound common carotid artery image based on active contour model

Author keywords

B Mode Ultrasound Image; Common Carotid Artery (CCA); GVF Snake; Image Segmentation; Intima Media Thinkness (IMT)

Indexed keywords

ACTIVE CONTOUR MODEL; AUTOMATIC DETECTION; B-MODE ULTRASOUND IMAGES; CAROTID ARTERY; CLINICAL PRACTICES; COMMON CAROTID ARTERY; COMPUTER-BASED TECHNIQUES; GVF-SNAKE; IMAGE-BASED; INTEGRATED APPROACH; INTIMA-MEDIA THICKNESS; INTIMA-MEDIA THINKNESS (IMT); MANUAL SEGMENTATION; MEAN ERRORS; MEDIA LAYERS; REGION IDENTIFICATION; RISK INDICES; SEGMENTATION ERROR; THRESHOLD SEGMENTATION; ULTRASOUND IMAGES; USER INTERACTION;

EID: 84863039988     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBMI.2011.48     Document Type: Conference Paper
Times cited : (5)

References (14)
  • 1
    • 0030826182 scopus 로고    scopus 로고
    • Common carotid intima-media thickness and risk of stroke and myocardial infarction: The Rotterdam Study
    • Bots ML, Hoes AW, Koudstaal PJ, Hofman A, Grobbee DE, Common carotid intima-media thickness and risk of stroke and myocardial infarction: the Rotterdam Study. Circulation 96:1432-1437, 1997. (Pubitemid 27375333)
    • (1997) Circulation , vol.96 , Issue.5 , pp. 1432-1437
    • Bots, M.L.1    Hoes, A.W.2    Koudstaal, P.J.3    Hofman, A.4    Grobbee, D.E.5
  • 2
    • 0033624995 scopus 로고    scopus 로고
    • Multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
    • DOI 10.1109/42.836372
    • Liang Q, Wendelhag I, Wikstrand J, Gustavsson T, A multiscale dynamic programming procedure for boundary detection in ultrasounic artery images. IEEE Trans Med Imaging 19:127-142, 2000. (Pubitemid 30594808)
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.2 , pp. 127-142
    • Liang, Q.1    Wendelhag, I.2    Wikstrand, J.3    Gustavsson, T.4
  • 3
    • 21244436028 scopus 로고    scopus 로고
    • Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software
    • Secil M, Altay C, Gulcu A, Cece H, Goktay AY, Dicle O, Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software. Diagn Interv Radiol 11:105-108, 2005. (Pubitemid 40894890)
    • (2005) Diagnostic and Interventional Radiology , vol.11 , Issue.2 , pp. 105-108
    • Secil, M.1    Altay, C.2    Gulcu, A.3    Cece, H.4    Goktay, A.Y.5    Dicle, O.6
  • 5
    • 0036870577 scopus 로고    scopus 로고
    • Speckle reducing anisotropic diffusion
    • Yu Y, Acton ST, Speckle reducing anisotropic diffusion. IEEE Trans Images Process 11(11):1260-1270, 2002.
    • (2002) IEEE Trans Images Process , vol.11 , Issue.11 , pp. 1260-1270
    • Yu, Y.1    Acton, S.T.2
  • 6
    • 0031340208 scopus 로고    scopus 로고
    • Implementation and Comparison of Four Different Boundary Detection Algorithms for Quantitative Ultrasonic Measurements of the Human Carotid Artery
    • T. Gustavsson, R. Abu-Gharbieh, G. Hamameh and Q. Liang, Implementation and Comparison of Four Different Boundary Detection Algorithms for Quantitative Ultrasonic Measurements of the Human Carotid Artery, IEEE Computers in Cardiology, vol. 24, 1997, pp. 69-72.
    • (1997) IEEE Computers in Cardiology , vol.24 , pp. 69-72
    • Gustavsson, T.1    Abu-Gharbieh, R.2    Hamameh, G.3    Liang, Q.4
  • 7
    • 0035720717 scopus 로고    scopus 로고
    • An Automatic Measurement System for the Evaluation of Carotid Intima-Media Thickness
    • C. Liguori, A. Paolillo and A. Pietrosanto, An Automatic Measurement System for the Evaluation of Carotid Intima-Media Thickness, IEEE Trans. on Instr. and Meas., vol. 50, pp. 1684-1691, 2001.
    • (2001) IEEE Trans. on Instr. and Meas. , vol.50 , pp. 1684-1691
    • Liguori, C.1    Paolillo, A.2    Pietrosanto, A.3
  • 8
    • 0036139071 scopus 로고    scopus 로고
    • Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images
    • DOI 10.1016/S0169-2607(00)00149-8, PII S0169260700001498
    • D. Cheng, A. Schmidt-Trucksass, K. Cheng, and H. Burkhardt, Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images, Computer Methods and Programs in Biomedicine, vol. 67, pp. 27-37, 2002. (Pubitemid 34031723)
    • (2002) Computer Methods and Programs in Biomedicine , vol.67 , Issue.1 , pp. 27-37
    • Cheng, D.-C.1    Schmidt-Trucksass, A.2    Cheng, K.-S.3    Burkhardt, H.4
  • 9
    • 4244087040 scopus 로고
    • Ultrasound B-mode imaging in observational studies of atherosclerotic progression
    • Salonen JT, Salonen R, Ultrasound B-mode imaging in observational studies of atherosclerotic progression, Circulation 87(II):1156-1165, 1993.
    • (1993) Circulation , vol.87 , Issue.2 , pp. 1156-1165
    • Salonen, J.T.1    Salonen, R.2
  • 10
    • 83455234965 scopus 로고    scopus 로고
    • Dectection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique
    • 20 July, (online version)
    • N. Santhiyakumari, P. Rajendran, M. Madheswaran, Dectection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique, Med Biol Eng Comput, 20 July, 2011 (online version).
    • (2011) Med Biol Eng Comput
    • Santhiyakumari, N.1    Rajendran, P.2    Madheswaran, M.3
  • 11
    • 0026741340 scopus 로고
    • A fast algorithm for active contours and curvature estimation
    • J
    • Williams D J, Shah M, A fast algorithm for active contours and curvature estimation [J].CVGIP: Image Understanding, 55(1): 14-26, 1992.
    • (1992) CVGIP: Image Understanding , vol.55 , Issue.1 , pp. 14-26
    • Williams, D.J.1    Shah, M.2
  • 14
    • 0032028944 scopus 로고    scopus 로고
    • Snakes, shapes, and gradient vector flow
    • PII S105771499801745X
    • Xu C, Prince J L, Snakes, shapes, and gradient vector flow [J]. IEEE Transactions on Image Processing, 7(3): 359-369. 1998. (Pubitemid 128745354)
    • (1998) IEEE Transactions on Image Processing , vol.7 , Issue.3 , pp. 359-369
    • Xu, C.1    Prince, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.