메뉴 건너뛰기




Volumn 62, Issue 2, 2012, Pages 660-664

Local head gradient coils: Window(s) of opportunity

Author keywords

Echo planar imaging; Functional MRI (fMRI); Local gradient coil

Indexed keywords

BOLD SIGNAL; BRAIN FUNCTION; ECHO PLANAR IMAGING; EQUIPMENT DESIGN; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HISTORICAL RESEARCH; HUMAN; LOCAL HEAD GRADIENT COIL; MAGNETIC FIELD; MEDICAL SCHOOL; NERVE CELL NETWORK; NERVE STIMULATION; NEUROIMAGING; NEUROPHYSIOLOGY; NUCLEAR MAGNETIC RESONANCE SCANNER; PATIENT SAFETY; PRIORITY JOURNAL; RADIODIAGNOSTIC EQUIPMENT AND SUPPLIES; REVIEW; TISSUE PERFUSION;

EID: 84862992641     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2012.01.025     Document Type: Review
Times cited : (16)

References (16)
  • 2
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5T
    • Hayes C.E., Edelstein W.A., Schenk J.F., Mueller O.M. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5T. J. Magn. Reson. 1985, 63:622-628.
    • (1985) J. Magn. Reson. , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenk, J.F.3    Mueller, O.M.4
  • 3
    • 77955778890 scopus 로고    scopus 로고
    • Theory of gradient coil design methods for magnetic resonance imaging
    • Hidalgo-Tobon S.S. Theory of gradient coil design methods for magnetic resonance imaging. Concepts Magn. Reson. A 2010, 36A:223-242.
    • (2010) Concepts Magn. Reson. A , vol.36 A , pp. 223-242
    • Hidalgo-Tobon, S.S.1
  • 7
    • 84872210336 scopus 로고    scopus 로고
    • The NIH Human Connectome Project
    • The NIH Human Connectome Project http://humanconnectome.org/.
  • 8
    • 0022768413 scopus 로고
    • A target field approach to optimal coil design
    • Turner R. A target field approach to optimal coil design. J. Appl. Phys. 1986, 19:L147.
    • (1986) J. Appl. Phys. , vol.19
    • Turner, R.1
  • 10
    • 0002945717 scopus 로고
    • Shim insensitive phase correction for EPI using a two echo reference scan
    • Wong E.C. Shim insensitive phase correction for EPI using a two echo reference scan. Proc., SMRM, 11th Annual Meeting, Berlin 1992, 4514.
    • (1992) Proc., SMRM, 11th Annual Meeting, Berlin , pp. 4514
    • Wong, E.C.1
  • 12
    • 0025941642 scopus 로고
    • Coil optimization for MRI by conjugate gradient descent
    • Wong E.C., Jesmanowicz A., Hyde J.S. Coil optimization for MRI by conjugate gradient descent. Magn. Reson. Med. 1991, 21:39-48.
    • (1991) Magn. Reson. Med. , vol.21 , pp. 39-48
    • Wong, E.C.1    Jesmanowicz, A.2    Hyde, J.S.3
  • 13
    • 0026075519 scopus 로고
    • High resolution short TE MR imaging of the fingers and wrist with a local gradient coil
    • Wong E.C., Jesmanowicz A., Hyde J.S. High resolution short TE MR imaging of the fingers and wrist with a local gradient coil. Radiology 1991, 181:393-397.
    • (1991) Radiology , vol.181 , pp. 393-397
    • Wong, E.C.1    Jesmanowicz, A.2    Hyde, J.S.3
  • 16


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.