메뉴 건너뛰기




Volumn 7, Issue 1, 2010, Pages 19-25

Analysis of Biological Apatite Orientation in Rat Mandibles

Author keywords

biological apatite (BAp) crystallite; bone quality; mandible; microbeam X ray diffraction; stress distribution

Indexed keywords


EID: 84862957752     PISSN: 13488643     EISSN: None     Source Type: Journal    
DOI: 10.11277/osi.osi201002     Document Type: Article
Times cited : (9)

References (9)
  • 2
    • 0035857351 scopus 로고    scopus 로고
    • Osteoporosis prevention, diagnosis, and therapy
    • NIH Consensus Development Panel: Osteoporosis prevention, diagnosis, and therapy. JAMA 285 : 785–795, 2001.
    • (2001) JAMA , vol.285 , pp. 785-795
  • 3
    • 16644381911 scopus 로고    scopus 로고
    • Assessment of bone quality -present and future-
    • Ito M.: Assessment of bone quality -present and future-. Clin Calcium 14 : 1833–1838, 2004.
    • (2004) Clin Calcium , vol.14 , pp. 1833-1838
    • Ito, M.1
  • 4
    • 0027210851 scopus 로고
    • Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women
    • Ross P.D., Genant H.K., Davis J.W., Miller P.D., and Wasnich R.D.: Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women. Osteoporosis Int 3 : 120–126, 1993.
    • (1993) Osteoporosis Int , vol.3 , pp. 120-126
    • Ross, P.D.1    Genant, H.K.2    Davis, J.W.3    Miller, P.D.4    Wasnich, R.D.5
  • 5
    • 0003480323 scopus 로고
    • Structure and Chemistry of the Apatites and Other Calcium Phosphates
    • Elliot J.C.: Structure and Chemistry of the Apatites and Other Calcium Phosphates: Elsevier Science, Amsterdam, 1994, pp.1–389.
    • (1994) Elsevier Science, Amsterdam , pp. 1-389
    • Elliot, J.C.1
  • 6
    • 0036794941 scopus 로고    scopus 로고
    • Unique alignment and texture of biological apatite crystallites in typical calcified tissues analyzed by microbeam X-ray diffractometer system
    • Nakano T., Kaibara K., Tabata Y., Nagata N., Enomoto S., Marukawa E., and Umakoshi Y.: Unique alignment and texture of biological apatite crystallites in typical calcified tissues analyzed by microbeam X-ray diffractometer system. Bone 31 : 479–487, 2002.
    • (2002) Bone , vol.31 , pp. 479-487
    • Nakano, T.1    Kaibara, K.2    Tabata, Y.3    Nagata, N.4    Enomoto, S.5    Marukawa, E.6    Umakoshi, Y.7
  • 7
    • 85024725101 scopus 로고    scopus 로고
    • Hard tissue mechanical properties of bone. Encyclopedia of Materials
    • Rho J.H.: Hard tissue mechanical properties of bone. Encyclopedia of Materials. Science and Technology, 2001, pp.3722–3728.
    • (2001) Science and Technology , pp. 3722-3728
    • Rho, J.H.1
  • 8
    • 0019170174 scopus 로고
    • Orientation of apatite crystals in relation to muscle attachment in the mandible
    • Bacon G.E., Bacon P.J., and Griffiths R.K.: Orientation of apatite crystals in relation to muscle attachment in the mandible. J Biomech 13 : 725–729, 1980.
    • (1980) J Biomech , vol.13 , pp. 725-729
    • Bacon, G.E.1    Bacon, P.J.2    Griffiths, R.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.