메뉴 건너뛰기




Volumn 31, Issue 5, 2011, Pages 551-557

Early initiation of continuous ambulatory peritoneal dialysis in patients undergoing surgical implantation of tenckhoff catheters

Author keywords

Break in procedure; CAPD; Complications; Tenckhoff catheter

Indexed keywords

ADULT; ARTICLE; CATHETER; CATHETER COMPLICATION; CATHETER LEAKAGE; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; CONTROLLED STUDY; FEMALE; HEMOPERITONEUM; HUMAN; IMPLANTATION; KIDNEY FAILURE; MAJOR CLINICAL STUDY; MALE; PERICATHETER HERNIA; PERICATHETER INFECTION; PERITONITIS; PRIORITY JOURNAL; RENAL REPLACEMENT THERAPY; RETROSPECTIVE STUDY; SAFETY; TENCKHOFF CATHETER;

EID: 84862942430     PISSN: 08968608     EISSN: 17184304     Source Type: Journal    
DOI: 10.3747/pdi.2009.00171     Document Type: Article
Times cited : (81)

References (22)
  • 4
    • 0035234862 scopus 로고    scopus 로고
    • Dialysate leaks in peritoneal dialysis
    • Leblanc M, Ouimet D, Pichette V. Dialysate leaks in peritoneal dialysis. Semin Dial 2001; 14:50-4.
    • (2001) Semin Dial , vol.14 , pp. 50-54
    • Leblanc, M.1    Ouimet, D.2    Pichette, V.3
  • 6
    • 30944457119 scopus 로고    scopus 로고
    • Early start of CAPD with the Seldinger technique
    • Banli O, Altun H, Oztemel A. Early start of CAPD with the Seldinger technique. Perit Dial Int 2005; 25:556-9.
    • (2005) Perit Dial Int , vol.25 , pp. 556-559
    • Banli, O.1    Altun, H.2    Oztemel, A.3
  • 7
    • 34248996507 scopus 로고    scopus 로고
    • Immediate initiation of CAPD following percutaneous catheter placement without break-in procedure
    • Jo YI, Shin SK, Lee JH, Song JO, Park JH. Immediate initiation of CAPD following percutaneous catheter placement without break-in procedure. Perit Dial Int 2007; 27:179-83.
    • (2007) Perit Dial Int , vol.27 , pp. 179-183
    • Jo, Y.I.1    Shin, S.K.2    Lee, J.H.3    Song, J.O.4    Park, J.H.5
  • 8
    • 58149117605 scopus 로고    scopus 로고
    • Shorter break-in period is a viable option with tighter PD catheter securing during the insertion
    • Sharma AP, Mandhani A, Daniel SP, Filler g. Shorter break-in period is a viable option with tighter PD catheter securing during the insertion. Nephrology (Carlton) 2008; 13:672-6.
    • (2008) Nephrology (Carlton) , vol.13 , pp. 672-676
    • Sharma, A.P.1    Mandhani, A.2    Daniel, S.P.3    Filler, G.4
  • 9
    • 0242299640 scopus 로고    scopus 로고
    • Three purse-string sutures allow immediate start of peritoneal dialysis with a low incidence of leakage
    • Stegmayr Bg. Three purse-string sutures allow immediate start of peritoneal dialysis with a low incidence of leakage. Semin Dial 2003; 16:346-8.
    • (2003) Semin Dial , vol.16 , pp. 346-348
    • Stegmayr, B.G.1
  • 10
    • 0027438675 scopus 로고
    • Stylet with a curved tip to facilitate introduction of new Tenckhoff catheters and reposition of displaced ones. Surgical technique
    • Stegmayr BG, Hedberg B, Norrgård O. Stylet with a curved tip to facilitate introduction of new Tenckhoff catheters and reposition of displaced ones. Surgical technique. Eur J Surg 1993; 159:495-7.
    • (1993) Eur J Surg , vol.159 , pp. 495-497
    • Stegmayr, B.G.1    Hedberg, B.2    Norrgård, O.3
  • 11
    • 84979340034 scopus 로고
    • Mechanical complications of chronic peritoneal dialysis catheters
    • Diaz-Buxo JA. Mechanical complications of chronic peritoneal dialysis catheters. Semin Dial 1991; 4:106-11.
    • (1991) Semin Dial , vol.4 , pp. 106-111
    • Diaz-Buxo, J.A.1
  • 12
    • 0027249579 scopus 로고
    • Paramedian insertion of Tenckhoff catheters with three purse-string sutures reduces the risk of leakage
    • Stegmayr Bg. Paramedian insertion of Tenckhoff catheters with three purse-string sutures reduces the risk of leakage. Perit Dial Int 1993; 13(Suppl 2):S124-6.
    • (1993) Perit Dial Int , vol.13 , Issue.SUPPL. 2
    • Stegmayr, B.G.1
  • 13
    • 0023921649 scopus 로고
    • Insertion of peritoneal dialysis catheters: The lateral approach
    • Patterson RB, Whelan TV, Schwab CW. Insertion of peritoneal dialysis catheters: the lateral approach. South Med J 1988; 81:577-9.
    • (1988) South Med J , vol.81 , pp. 577-579
    • Patterson, R.B.1    Whelan, T.V.2    Schwab, C.W.3
  • 14
    • 0025252167 scopus 로고
    • Absence of leakage by insertion of peritoneal dialysis catheter through the rectus muscle
    • Stegmayr B, Hedberg B, Sandzen B, Wikdahl AM. Absence of leakage by insertion of peritoneal dialysis catheter through the rectus muscle. Perit Dial Int 1990; 10:53-5.
    • (1990) Perit Dial Int , vol.10 , pp. 53-55
    • Stegmayr, B.1    Hedberg, B.2    Sandzen, B.3    Wikdahl, A.M.4
  • 15
    • 7144223406 scopus 로고    scopus 로고
    • Peritoneal catheters and exit-site practices toward optimum peritoneal access: 1998 update
    • Gokal R, Alexander S, Ash S, Chen TW, Danielson A, Holmes C, et al. Peritoneal catheters and exit-site practices toward optimum peritoneal access: 1998 update. Perit Dial Int 1998; 18:11-33.
    • (1998) Perit Dial Int , vol.18 , pp. 11-33
    • Gokal, R.1    Alexander, S.2    Ash, S.3    Chen, T.W.4    Danielson, A.5    Holmes, C.6
  • 16
    • 34447532209 scopus 로고    scopus 로고
    • Intraperitoneal pressure in PD patients: Relationship to intraperitoneal volume, body size and PD-related complications
    • Dejardin A, Robert A, Goffin E. Intraperitoneal pressure in PD patients: relationship to intraperitoneal volume, body size and PD-related complications. Nephrol Dial Transplant 2007; 22:1437-44.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 1437-1444
    • Dejardin, A.1    Robert, A.2    Goffin, E.3
  • 17
    • 44949209420 scopus 로고    scopus 로고
    • Peritonitis and exit site infection
    • In: Daugirdas JT, Blake Pg, Ing TS, eds., 4th ed. Philadelphia: Lippincott Williams & Wilkins
    • Leehey DJ, Szeto CC, Li P. Peritonitis and exit site infection. In: Daugirdas JT, Blake Pg, Ing TS, eds. Handbook of Dialysis. 4th ed. Philadelphia: Lippincott Williams & Wilkins; 2007: 417-39.
    • (2007) Handbook of Dialysis , pp. 417-439
    • Leehey, D.J.1    Szeto, C.C.2    Li, P.3
  • 18
    • 0029830071 scopus 로고    scopus 로고
    • Peritonitis associated with exit site and tunnel infections
    • Gupta B, Bernardini J, Piraino B. Peritonitis associated with exit site and tunnel infections. Am J Kidney Dis 1996; 28:415-19.
    • (1996) Am J Kidney Dis , vol.28 , pp. 415-419
    • Gupta, B.1    Bernardini, J.2    Piraino, B.3
  • 19
    • 0027184314 scopus 로고
    • Reduction in peritonitis incidence in continuous ambulatory peritoneal dialysis with a new catheter and implantation technique
    • Moncrief JW, Popovich RP, Dasgupta M, Costerton JW, Simmons E, Moncrief B. Reduction in peritonitis incidence in continuous ambulatory peritoneal dialysis with a new catheter and implantation technique. Perit Dial Int 1993; 13(Suppl 2):S329-31.
    • (1993) Perit Dial Int , vol.13 , Issue.SUPPL. 2
    • Moncrief, J.W.1    Popovich, R.P.2    Dasgupta, M.3    Costerton, J.W.4    Simmons, E.5    Moncrief, B.6
  • 20
    • 0041384561 scopus 로고    scopus 로고
    • Risk factors for abdominal wall complications in peritoneal dialysis patients
    • del Peso G, Bajo MA, Costero O, Hevia C, Gil F, Díaz C, et al. Risk factors for abdominal wall complications in peritoneal dialysis patients. Perit Dial Int 2003; 23:249-54.
    • (2003) Perit Dial Int , vol.23 , pp. 249-254
    • del Peso, G.1    Bajo, M.A.2    Costero, O.3    Hevia, C.4    Gil, F.5    Díaz, C.6
  • 21
    • 0242331143 scopus 로고    scopus 로고
    • Managing the complications of long-term tunneled dialysis catheters
    • Schon D, Whittman D. Managing the complications of long-term tunneled dialysis catheters. Semin Dial 2003; 16:314-22.
    • (2003) Semin Dial , vol.16 , pp. 314-322
    • Schon, D.1    Whittman, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.