메뉴 건너뛰기




Volumn , Issue , 2011, Pages 205-208

A wireless ECG plaster for real-time cardiac health monitoring in body sensor networks

Author keywords

ECG on Chip; Electrocardiography; Real time monitoring; Wearable devices

Indexed keywords

BATTERY LIFE; CARDIAC HEALTH; CARDIAC PATIENTS; CLINICAL TRIAL; CONTINUOUS OPERATION; ECG SIGNALS; ECG-ON-CHIP; FRONT-END CHIPS; LIGHT WEIGHT; REAL TIME MONITORING; ULTRA-LOW POWER; WEARABLE DEVICES; ZIG-BEE;

EID: 84862942090     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioCAS.2011.6107763     Document Type: Conference Paper
Times cited : (13)

References (6)
  • 1
    • 84862936045 scopus 로고    scopus 로고
    • http://www.americanheart.org/downloadable/heart/1200082005246HS- Stats%202008.final.pdf
  • 2
    • 0035832261 scopus 로고    scopus 로고
    • Prevalence of diagnosed atrial fibrillation in adults. National implications for rhythm management and stroke prevention: The AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study
    • A.S. Go, E.M. Hylek, K.A. Phillips, et al., "Prevalence of diagnosed atrial fibrillation in adults. National implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors In Atrial Fibrillation (ATRIA) Study," JAMA., 285, pp. 2370-2375, 2001.
    • (2001) JAMA , vol.285 , pp. 2370-2375
    • Go, A.S.1    Hylek, E.M.2    Phillips, K.A.3
  • 3
    • 0141742178 scopus 로고    scopus 로고
    • Diagnostic yield of external electrocardiographic loop recorders in patients with recurrent syncope and negative Tilt table test
    • A. Schuchert, R. Maas, C. Kretzschmar, G. Behrens, I. Kratzman, T. Meinertz, "Diagnostic yield of external electrocardiographic loop recorders in patients with recurrent syncope and negative Tilt table test," PACE, 26, pp.1837-1840, 2003.
    • (2003) PACE , vol.26 , pp. 1837-1840
    • Schuchert, A.1    Maas, R.2    Kretzschmar, C.3    Behrens, G.4    Kratzman, I.5    Meinertz, T.6
  • 4
    • 63449088602 scopus 로고    scopus 로고
    • A 1-V 450-nW fully integrated programmable biomedical sensor interface chip
    • Apr
    • X.D. Zou, X.Y. Xu, L.B. Yao, and Y. Lian, "A 1-V 450-nW Fully Integrated Programmable Biomedical Sensor Interface Chip," IEEE Journal of Solid-State Circuits, vol. 44, no. 4, pp. 1067-1077, Apr. 2009.
    • (2009) IEEE Journal of Solid-State Circuits , vol.44 , Issue.4 , pp. 1067-1077
    • Zou, X.D.1    Xu, X.Y.2    Yao, L.B.3    Lian, Y.4
  • 6
    • 68449087485 scopus 로고    scopus 로고
    • QRS detection based on multi-scale mathematical morphology for wearable ECG device in body area networks
    • Aug
    • F. Zhang, and Y. Lian, "QRS Detection Based on Multi-Scale Mathematical Morphology for Wearable ECG Device in Body Area Networks," IEEE Transactions on Biomedical Circuits and Systems, Vol.3, No.4, pp.220-228, Aug. 2009.
    • (2009) IEEE Transactions on Biomedical Circuits and Systems , vol.3 , Issue.4 , pp. 220-228
    • Zhang, F.1    Lian, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.