메뉴 건너뛰기




Volumn , Issue , 2011, Pages 377-380

Sensor interface with single-line quasi-digital output for ligament balance measuring system

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE AREA; BATTERY APPLICATIONS; CMOS PROCESSS; FRONT-END CIRCUITS; MEASURING SYSTEMS; RESISTIVE BRIDGE SENSORS; SAMPLE-AND-HOLD; SENSOR INTERFACE; TIMING CONTROL; TOTAL KNEE ARTHROPLASTY; VOLTAGE SUPPLY;

EID: 84862916484     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioCAS.2011.6107806     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 73249149326 scopus 로고    scopus 로고
    • Low-power circuits for the bidirectional wireless monitoring system of the orthopedic implants
    • December
    • H. Chen, M. Liu, W. Hao, Y. Chen, C. Zhang, Z. Wang "Low-Power Circuits for the Bidirectional Wireless Monitoring System of the Orthopedic Implants," IEEE trans. biomed. circuits syst., vol. 3, Issue 6, pp. 437-443, December 2009.
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.6 , pp. 437-443
    • Chen, H.1    Liu, M.2    Hao, W.3    Chen, Y.4    Zhang, C.5    Wang, Z.6
  • 2
    • 78650835287 scopus 로고    scopus 로고
    • Low-power circuits design for the wireless force measurement system of the total knee arthroplasty
    • Argentina, September
    • H. Chen, M. Liu, W. Wan, C. Jia, C. Zhang, Z. Wang, "Low-power Circuits Design for the Wireless Force Measurement System of the Total Knee Arthroplasty", IEEE EMBS, Argentina, September 2010.
    • (2010) IEEE EMBS
    • Chen, H.1    Liu, M.2    Wan, W.3    Jia, C.4    Zhang, C.5    Wang, Z.6
  • 3
    • 26844524337 scopus 로고    scopus 로고
    • Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA
    • September
    • D. Crottet, T. Maeder, D. Fritschy, H. Bleuler, L.. Nolte, and I. P. Pappas, "Development of a Force Amplitude- and Location-Sensing Device Designed to Improve the Ligament Balancing Procedure in TKA," IEEE Trans Biomed. Eng., vol. 52, no. 9, pp. 1609-1611, September 2005.
    • (2005) IEEE Trans Biomed. Eng. , vol.52 , Issue.9 , pp. 1609-1611
    • Crottet, D.1    Maeder, T.2    Fritschy, D.3    Bleuler, H.4    Nolte, L.5    Pappas, I.P.6
  • 6
    • 0034988888 scopus 로고    scopus 로고
    • Forces and moments telemetered from two distal femoral replacements during various activities
    • S. J. G. Taylor and P. S.Walker, "Forces and moments telemetered from two distal femoral replacements during various activities," J. Biomech., vol. 34, pp. 839-848, 2001.
    • (2001) J. Biomech. , vol.34 , pp. 839-848
    • Taylor, S.J.G.1    Walker, P.S.2
  • 7
  • 8
    • 84862968924 scopus 로고    scopus 로고
    • AD7794 datasheet, http://www.analog.com/static/imported-files/data- sheets/AD7794-7795.pdf.
    • AD7794 Datasheet
  • 9
    • 85028216106 scopus 로고    scopus 로고
    • UTI datasheet, http://www.smartec.nl/pdf/DSUTI.pdf.
    • UTI Datasheet
  • 10
    • 84862961607 scopus 로고    scopus 로고
    • FSS15000NGT datasheet, http://sensing.honeywell.com/index.cfm/ci-id/ 156199/la-id/1/document/1/re-id/0
    • FSS15000NGT Datasheet
  • 12
    • 34347235473 scopus 로고    scopus 로고
    • ASIC frontend interface with frequency and duty cycle output for resistivebridge sensors
    • V. Ferrari, A. Ghisla, V. Z. Kovacs, D. Marioli, A. Taroni, "ASIC frontend interface with frequency and duty cycle output for resistivebridge sensors", S. & A. A, vol.138, no.1, pp.112-119, 2007.
    • (2007) S. & A. A , vol.138 , Issue.1 , pp. 112-119
    • Ferrari, V.1    Ghisla, A.2    Kovacs, V.Z.3    Marioli, D.4    Taroni, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.