메뉴 건너뛰기




Volumn 43, Issue 7, 2012, Pages 1061-1065

Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty

Author keywords

Femur; Finite element analysis; Periprosthetic fracture; Total hip arthroplasty; Vancouver type B1

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; CANCELLOUS BONE; COMPUTER PROGRAM; CORTICAL BONE; FEMUR; FINITE ELEMENT ANALYSIS; FIXATION DEVICE; HIP PROSTHESIS; PERIPROSTHETIC FRACTURE; PRIORITY JOURNAL; STRESS; SURGICAL EQUIPMENT; TOTAL HIP PROSTHESIS; VANCOUVER TYPE B1 PERIPROSTHETIC FRACTURE; YOUNG MODULUS;

EID: 84862904084     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2012.01.015     Document Type: Article
Times cited : (30)

References (28)
  • 2
    • 76249115492 scopus 로고    scopus 로고
    • Does femoral component loosening predispose to femoral fracture? An in vitro comparison of cemented hips
    • Harris B, Owen JR, Wayne JS, Jiranek WA. Does femoral component loosening predispose to femoral fracture? An in vitro comparison of cemented hips. Clin Orthop Relat Res 2010;468:497-503.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 497-503
    • Harris, B.1    Owen, J.R.2    Wayne, J.S.3    Jiranek, W.A.4
  • 3
    • 79957839348 scopus 로고    scopus 로고
    • Periprosthetic proximal femur fractures: Current concepts
    • Parvizi J, Vegari DN. Periprosthetic proximal femur fractures: current concepts. J Orthop Trauma 2011;25(Suppl 2):S77-81.
    • (2011) J Orthop Trauma , vol.25 , Issue.SUPPL. 2
    • Parvizi, J.1    Vegari, D.N.2
  • 4
    • 0031602321 scopus 로고    scopus 로고
    • Periprosthetic fracture of the femur after total hip arthroplasty: Treatment and results to date
    • Lewallen DG, Berry DJ. Periprosthetic fracture of the femur after total hip arthroplasty: treatment and results to date. Instr Course Lect 1998;47:243-9.
    • (1998) Instr Course Lect , vol.47 , pp. 243-249
    • Lewallen, D.G.1    Berry, D.J.2
  • 5
    • 34248162402 scopus 로고    scopus 로고
    • Epidemiology of periprosthetic femur fracture around a total hip arthroplasty
    • DOI 10.1016/j.injury.2007.02.048, PII S0020138307001003, Periprosthetic Femoral Fractures
    • Lindahl H. Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury 2007;38:651-4. (Pubitemid 46726315)
    • (2007) Injury , vol.38 , Issue.6 , pp. 651-654
    • Lindahl, H.1
  • 7
    • 26844563975 scopus 로고    scopus 로고
    • Periprosthetic femoral fractures: Classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register
    • DOI 10.1016/j.arth.2005.02.001, PII S0883540305001117
    • Lindahl H, Malchau H, Herberts P, Garellick G. Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish national hip arthroplasty register. J Arthroplasty 2005;20:857-65. (Pubitemid 41463684)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.7 , pp. 857-865
    • Lindahl, H.1    Malchau, H.2    Herberts, P.3    Garellick, G.4
  • 8
    • 34047249098 scopus 로고    scopus 로고
    • The excess mortality due to periprosthetic femur fracture. A study from the Swedish national hip arthroplasty register
    • DOI 10.1016/j.bone.2007.01.003, PII S8756328207000063
    • Lindahl H, Oden A, Garellick G, Malchau H. The excess mortality due to periprosthetic femur fracture. A study from the Swedish national hip arthroplasty register. Bone 2007;40:1294-8. (Pubitemid 46550984)
    • (2007) Bone , vol.40 , Issue.5 , pp. 1294-1298
    • Lindahl, H.1    Oden, A.2    Garellick, G.3    Malchau, H.4
  • 9
    • 0033983833 scopus 로고    scopus 로고
    • The reliability and validity of the Vancouver classification of femoral fractures after hip replacement
    • Brady OH, Garbuz DS, Masri BA, Duncan CP. The reliability and validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 2000;15:59-62. (Pubitemid 30053520)
    • (2000) Journal of Arthroplasty , vol.15 , Issue.1 , pp. 59-62
    • Brady, O.H.1    Garbuz, D.S.2    Masri, B.A.3    Duncan, C.P.4
  • 10
    • 77950917533 scopus 로고    scopus 로고
    • Management of late periprosthetic femur fractures: A retrospective cohort of 72 patients
    • Mukundan C, Rayan F, Kheir E, Macdonald D. Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 2010;34: 485-9.
    • (2010) Int Orthop , vol.34 , pp. 485-489
    • Mukundan, C.1    Rayan, F.2    Kheir, E.3    Macdonald, D.4
  • 11
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: A biomechanical study of 5 techniques
    • Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 2000;15:523-8. (Pubitemid 30413896)
    • (2000) Journal of Arthroplasty , vol.15 , Issue.4 , pp. 523-528
    • Dennis, M.G.1    Simon, J.A.2    Kummer, F.J.3    Koval, K.J.4    DiCesare, P.E.5
  • 12
    • 84857726933 scopus 로고    scopus 로고
    • Treatment of periprosthetic femoral fractures in hip arthroplasty
    • Park SK, Kim YG, Kim SY. Treatment of periprosthetic femoral fractures in hip arthroplasty. Clin Orthop Surg 2011;3:101-6.
    • (2011) Clin Orthop Surg , vol.3 , pp. 101-106
    • Park, S.K.1    Kim, Y.G.2    Kim, S.Y.3
  • 13
    • 77954774700 scopus 로고    scopus 로고
    • The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty
    • Lever JP, Zdero R, Nousiainen MT, Waddell JP, Schemitsch EH. The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty. J Orthop Surg Res 2010;5:45.
    • (2010) J Orthop Surg Res , vol.5 , pp. 45
    • Lever, J.P.1    Zdero, R.2    Nousiainen, M.T.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 14
    • 0002111683 scopus 로고
    • Fractures beneath hip prostheses: A special indication for Parham bands and plating
    • Ogden WS, Rendall J. Fractures beneath hip prostheses: a special indication for Parham bands and plating. Orthop Transm 1978;2:70.
    • (1978) Orthop Transm , vol.2 , pp. 70
    • Ogden, W.S.1    Rendall, J.2
  • 15
    • 0030131155 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite femur models
    • DOI 10.1016/0021-9290(95)00084-4
    • Cristofolini L, Viceconti M, Cappelino A, Toni A. Mechanical validation of whole bone composite femur models. J Biomech 1996;29:525-35. (Pubitemid 26065734)
    • (1996) Journal of Biomechanics , vol.29 , Issue.4 , pp. 525-535
    • Cristofolini, L.1    Viceconti, M.2    Cappello, A.3    Toni, A.4
  • 16
    • 55549145079 scopus 로고    scopus 로고
    • Structural properties of fourth-generation composite femurs and tibias
    • Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech 2008;41:3282-4.
    • (2008) J Biomech , vol.41 , pp. 3282-3284
    • Heiner, A.D.1
  • 18
    • 0029794126 scopus 로고    scopus 로고
    • Surgical management of intra- and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty
    • Schmotzer H, Tchedeyan GH, Dall DM. Surgical management of intro- and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty. J Arthroplasty 1996;11:709-17. (Pubitemid 26317962)
    • (1996) Journal of Arthroplasty , vol.11 , Issue.6 , pp. 709-717
    • Schmotzer, H.1    Tchejeyan, G.H.2    Dall, D.M.3
  • 19
    • 33744503191 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: A biomechanical comparison of locked plating and conventional cable plates
    • DOI 10.1097/01.bot.0000199119.38359.96, PII 0000513120060200000002
    • Fulkerson E, Koval K, Preston CF, Iesaka K, Kummer FJ, Egol KA. Fixation of periprosthetic femoral shaft fractures associated ith cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates. J Orthop Trauma 2006;20:89-93. (Pubitemid 44378174)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.2 , pp. 89-93
    • Fulkerson, E.1    Koval, K.2    Preston, C.F.3    Iesaka, K.4    Kummer, F.J.5    Egol, K.A.6
  • 22
    • 67651062204 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate
    • Ebraheim NA, Gomez C, Ramineni SK, Liu J. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma 2009;66:1152-7.
    • (2009) J Trauma , vol.66 , pp. 1152-1157
    • Ebraheim, N.A.1    Gomez, C.2    Ramineni, S.K.3    Liu, J.4
  • 24
    • 79953063322 scopus 로고    scopus 로고
    • Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30- Month follow-up
    • Xue H, Tu Y, Cai M, Yang A. Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30- month follow-up. J Arthroplasty 2011;26. pp. 467-471.e1.
    • (2011) J Arthroplasty , vol.26
    • Xue, H.1    Tu, Y.2    Cai, M.3    Yang, A.4
  • 25
    • 34248189246 scopus 로고    scopus 로고
    • The biomechanics of human femurs in axial and torsional loading: Comparison of finite element analysis, human cadaveric femurs, and synthetic femurs
    • DOI 10.1115/1.2401178
    • Papini M, Zdero R, Schemitsch EH, Zalzal P. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. J Biomech Eng 2007;129:12-9. (Pubitemid 46712831)
    • (2007) Journal of Biomechanical Engineering , vol.129 , Issue.1 , pp. 12-19
    • Papini, M.1    Zdero, R.2    Schemitsch, E.H.3    Zalzal, P.4
  • 26
    • 0026311111 scopus 로고
    • Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance
    • Szivek JA, Gealer R. Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance. J Appl Biomater 1991;2:277-80.
    • (1991) J Appl Biomater , vol.2 , pp. 277-280
    • Szivek, J.A.1    Gealer, R.2
  • 27
    • 0034163705 scopus 로고    scopus 로고
    • An experimental method for the application of lateral muscle loading and its effect on femoral strain distributions
    • DOI 10.1016/S1350-4533(00)00020-5, PII S1350453300000205
    • Szivek JA, Benjamin JB, Anderson PI. An experimental method for the application of lateral muscle loading and its effect on femoral strain distribution. Med Eng Phys 2000;22:109-16. (Pubitemid 30331019)
    • (2000) Medical Engineering and Physics , vol.22 , Issue.2 , pp. 109-116
    • Szivek, J.A.1    Benjamin, J.B.2    Anderson, P.L.3
  • 28
    • 0037212628 scopus 로고    scopus 로고
    • A new parametric approach for modeling hip forces during gait
    • DOI 10.1016/S0021-9290(02)00328-7, PII S0021929002003287
    • Hurwitz DE. A new parametric approach for modeling hip forces during gait. J Biomech 2003;36:113-9. (Pubitemid 35448100)
    • (2003) Journal of Biomechanics , vol.36 , Issue.1 , pp. 113-119
    • Hurwitz, D.E.1    Foucher, K.C.2    Andriacchi, T.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.