메뉴 건너뛰기




Volumn 43, Issue 7, 2012, Pages 1227-1228

Failure of PFNA: Helical blade perforation and tip-apex distance

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; BONE SCREW; FEMUR INTERTROCHANTERIC FRACTURE; FRACTURE REDUCTION; GERIATRIC PATIENT; HELICAL BLADE PERFORATION; HUMAN; INTRAMEDULLARY NAILING; LETTER; PERFORATION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; PROXIMAL FEMORAL NAIL ANTIROTATION; TREATMENT OUTCOME;

EID: 84862853051     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2011.10.024     Document Type: Letter
Times cited : (34)

References (9)
  • 1
    • 47549119043 scopus 로고    scopus 로고
    • The new proximal femoral nail antirotation (PFNA) in daily practice: Results of a multicentre clinical study
    • Simmermacher RK, Ljungqvist J, Bail H, Hockertz T, Vochteloo AJH, Ochs U, et al. The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 2008;39:932-9.
    • (2008) Injury , vol.39 , pp. 932-939
    • Simmermacher, R.K.1    Ljungqvist, J.2    Bail, H.3    Hockertz, T.4    Vochteloo, A.J.H.5    Ochs, U.6
  • 2
    • 59049089233 scopus 로고    scopus 로고
    • The PFNA proximal femur nail in treatment of unstable proximal femur fractures--3 cases of postoperative perforation of the helical blade into the hip joint
    • Brunner A, Jockel JA, Babst R. The PFNA proximal femur nail in treatment of unstable proximal femur fractures--3 cases of postoperative perforation of the helical blade into the hip joint. J Orthop Trauma 2008;22:731-6.
    • (2008) J Orthop Trauma , vol.22 , pp. 731-736
    • Brunner, A.1    Jockel, J.A.2    Babst, R.3
  • 3
    • 62549086509 scopus 로고    scopus 로고
    • The AO/ASIF proximal femoral nail antirotation (PFNA): A new design for the treatment of unstable proximal femoral fractures
    • Mereddy P, Kamath S, Ramakrishnan M, Malik H, Donnachie N. The AO/ASIF proximal femoral nail antirotation (PFNA): a new design for the treatment of unstable proximal femoral fractures. Injury 2009;40:428-32.
    • (2009) Injury , vol.40 , pp. 428-432
    • Mereddy, P.1    Kamath, S.2    Ramakrishnan, M.3    Malik, H.4    Donnachie, N.5
  • 4
    • 79957797998 scopus 로고    scopus 로고
    • Cutout of proximal femoral nail antirotation resulting from blocking of the gliding mechanism during fracture collapse
    • Cheung JPY, Chan CF. Cutout of proximal femoral nail antirotation resulting from blocking of the gliding mechanism during fracture collapse. J Orthop Trauma 2011;25:e51-5.
    • (2011) J Orthop Trauma , vol.25
    • Cheung, J.P.Y.1    Chan, C.F.2
  • 5
    • 80052226378 scopus 로고    scopus 로고
    • Acetabular perforation after medial migration of the helical blade through the femoral head after treatment of an unstable trochanteric fracture with proximal femoral nail antirotation (PFNA): A case report
    • Takigami I, Ohnishi K, Ito Y, Nagano A, Sumida H, Tanaka K, et al. Acetabular perforation after medial migration of the helical blade through the femoral head after treatment of an unstable trochanteric fracture with proximal femoral nail antirotation (PFNA): a case report. J Orthop Trauma 2011;25:e86-9.
    • (2011) J Orthop Trauma , vol.25
    • Takigami, I.1    Ohnishi, K.2    Ito, Y.3    Nagano, A.4    Sumida, H.5    Tanaka, K.6
  • 6
    • 80052883294 scopus 로고    scopus 로고
    • Forward progression of the helical blade into the pelvis after repair with the trochanter fixation nail (TFN)
    • Frank MA, Yoon RS, Yalamanchili P, Choung EW, Liporace FA. Forward progression of the helical blade into the pelvis after repair with the trochanter fixation nail (TFN). J Orthop Trauma 2011;25(10):e100-3.
    • (2011) J Orthop Trauma , vol.25 , Issue.10
    • Frank, M.A.1    Yoon, R.S.2    Yalamanchili, P.3    Choung, E.W.4    Liporace, F.A.5
  • 8
    • 33748159153 scopus 로고    scopus 로고
    • Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation
    • DOI 10.1016/j.injury.2006.06.008, PII S002013830600369X
    • Strauss E, Frank J, Lee J, Kummer FJ, Tejwani N. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury 2006;37:984-9. (Pubitemid 44311133)
    • (2006) Injury , vol.37 , Issue.10 , pp. 984-989
    • Strauss, E.1    Frank, J.2    Lee, J.3    Kummer, F.J.4    Tejwani, N.5
  • 9
    • 79952797372 scopus 로고    scopus 로고
    • Hip screw migration testing: First results for hip screws and helical blades utilizing a new oscillating test method
    • Born CT, Karich B, Bauer C, von Oldenburg G, Augat P. Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method. J Orthop Res 2011;29(5):760-6.
    • (2011) J Orthop Res , vol.29 , Issue.5 , pp. 760-766
    • Born, C.T.1    Karich, B.2    Bauer, C.3    Von Oldenburg, G.4    Augat, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.