메뉴 건너뛰기




Volumn , Issue , 2012, Pages 746-749

Detuning issues and performance of a novel implantable antenna for telemetry applications

Author keywords

biocompatibility; biotelemetry; implantable antenna; medical implant communications service (MICS) band; miniaturization; specific absorption rate (SAR)

Indexed keywords

ANTENNA MODEL; DETUNINGS; FINITE ELEMENT SIMULATIONS; GAIN ENHANCEMENT; IMPLANTABLE ANTENNAS; MEDICAL IMPLANT COMMUNICATIONS SERVICES; MINIATURIZATION; PERFORMANCE ISSUES; RESONANCE DETUNING; SAFETY PERFORMANCE; SPECIFIC ABSORPTION RATE; VARYING PARAMETERS;

EID: 84862838126     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EuCAP.2012.6206560     Document Type: Conference Paper
Times cited : (9)

References (17)
  • 1
    • 0033572135 scopus 로고    scopus 로고
    • Medical implant communications service (MICS) federal register
    • Dec.
    • "Medical implant communications service (MICS) federal register," Rules Reg., vol. 64, no. 240, pp. 69926-69934, Dec. 1999.
    • (1999) Rules Reg. , vol.64 , Issue.240 , pp. 69926-69934
  • 2
    • 4043114097 scopus 로고    scopus 로고
    • Implanted antennas inside a human body: Simulations, designs and characterizations
    • Aug.
    • J. Kim and Y. Rahmat-Samii, "Implanted antennas inside a human body: simulations, designs and characterizations," IEEE Trans. Microw. Theory Tech., vol. 52, pp. 1934-1943, Aug. 2004.
    • (2004) IEEE Trans. Microw. Theory Tech. , vol.52 , pp. 1934-1943
    • Kim, J.1    Rahmat-Samii, Y.2
  • 3
    • 22444440840 scopus 로고    scopus 로고
    • Miniaturized biocompatible microstrip antenna using genetic algorithm
    • Jun.
    • P. Soontornpipit, C.M. Furse, and Y.C. Chung, "Miniaturized biocompatible microstrip antenna using genetic algorithm," IEEE Trans. Antennas Propag., vol. 53, pp. 1939-1945, Jun. 2005.
    • (2005) IEEE Trans. Antennas Propag. , vol.53 , pp. 1939-1945
    • Soontornpipit, P.1    Furse, C.M.2    Chung, Y.C.3
  • 4
    • 80054995735 scopus 로고    scopus 로고
    • Performance of a novel miniature antenna implanted in the human head for wireless biotelemetry
    • Spokane, Washington
    • A. Kiourti, M. Christopoulou, and K.S. Nikita, "Performance of a novel miniature antenna implanted in the human head for wireless biotelemetry," in Proc. IEEE Int. Symp. Antennas Propag., Spokane, Washington, 2011, pp. 392-395.
    • (2011) Proc. IEEE Int. Symp. Antennas Propag. , pp. 392-395
    • Kiourti, A.1    Christopoulou, M.2    Nikita, K.S.3
  • 5
    • 77955340068 scopus 로고    scopus 로고
    • 3D- spiral small antenna design and realization for biomedical telemetry in the MICS band
    • Dec.
    • J. Abadia, F. Merli, J.F. Zurcher, J.R. Mosig, and A.K. Skrivervik, "3D- spiral small antenna design and realization for biomedical telemetry in the MICS band," Radioengineering, vol. 18, pp. 359-367, Dec. 2009.
    • (2009) Radioengineering , vol.18 , pp. 359-367
    • Abadia, J.1    Merli, F.2    Zurcher, J.F.3    Mosig, J.R.4    Skrivervik, A.K.5
  • 7
    • 84862871926 scopus 로고    scopus 로고
    • IEEE Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields, 3kHz to 300 GHz, IEEE Standard C95.1-1999
    • IEEE Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields, 3kHz to 300 GHz, IEEE Standard C95.1-1999.
  • 8
    • 84862871929 scopus 로고    scopus 로고
    • IEEE Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields, 3kHz to 300 GHz, IEEE Standard C95.1-2005
    • IEEE Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields, 3kHz to 300 GHz, IEEE Standard C95.1-2005.
  • 10
    • 69549088475 scopus 로고    scopus 로고
    • Implantable broadband circular stacked PIFA antenna for biotelemetry communication
    • W.-C. Liu, S.-H. Chen and C.-M. Wu, "Implantable broadband circular stacked PIFA antenna for biotelemetry communication," J. of Electromagn. Waves and Appl., vol. 2, pp. 1791-1800, 2008.
    • (2008) J. of Electromagn. Waves and Appl. , vol.2 , pp. 1791-1800
    • Liu, W.-C.1    Chen, S.-H.2    Wu, C.-M.3
  • 11
    • 62449084986 scopus 로고    scopus 로고
    • Bandwidth enhancement and size reduction of an implantable PIFA antenna for biotelemetry devices
    • W.-C. Liu, S.-H. Chen and C.-M. Wu, "Bandwidth enhancement and size reduction of an implantable PIFA antenna for biotelemetry devices," Microw. Opt. Technol. Letters, vol. 51, pp. 755-757, 2009.
    • (2009) Microw. Opt. Technol. Letters , vol.51 , pp. 755-757
    • Liu, W.-C.1    Chen, S.-H.2    Wu, C.-M.3
  • 14
    • 37349066285 scopus 로고    scopus 로고
    • Analysis of current density and specific absorption rate in biological tissue surrounding transcutaneous transformer for an artificial heart
    • Jan.
    • K. Shiba, M. Nukaya, T. Tsuji and K. Koshiji, "Analysis of current density and specific absorption rate in biological tissue surrounding transcutaneous transformer for an artificial heart," IEEE Trans. Biomed. Eng., vol. 55, pp. 205-213, Jan. 2008.
    • (2008) IEEE Trans. Biomed. Eng. , vol.55 , pp. 205-213
    • Shiba, K.1    Nukaya, M.2    Tsuji, T.3    Koshiji, K.4
  • 15
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues
    • C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues," Phys. Med. Biol., vol. 41, pp. 2231-2293, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2231-2293
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.