메뉴 건너뛰기




Volumn 23, Issue 7, 2012, Pages 981-983

Peripherally inserted central catheter tip malposition caused by power contrast medium injection

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM;

EID: 84862835734     PISSN: 10510443     EISSN: 15357732     Source Type: Journal    
DOI: 10.1016/j.jvir.2012.04.024     Document Type: Letter
Times cited : (5)

References (9)
  • 1
  • 2
    • 0035141926 scopus 로고    scopus 로고
    • Power injection of contrast media using central venous catheters: Feasibility, safety, and efficacy
    • Herts BR, O'Malley CM, Wirth SL, Lieber ML, Pohlman B. Power injection of contrast media using central venous catheters: feasibility, safety, and efficacy. AJR Am J Roentgenol 2001; 176:447-453. (Pubitemid 32105659)
    • (2001) American Journal of Roentgenology , vol.176 , Issue.2 , pp. 447-453
    • Herts, B.R.1    O'Malley, C.M.2    Wirth, S.L.3    Lieber, M.L.4    Pohlman, B.5
  • 3
    • 79951940537 scopus 로고    scopus 로고
    • The use of central venous catheters for intravenous contrast injection for CT examinations
    • Plumb AA, Murphy G. The use of central venous catheters for intravenous contrast injection for CT examinations. Br J Radiol 2011; 84:197-203.
    • (2011) Br J Radiol , vol.84 , pp. 197-203
    • Plumb, A.A.1    Murphy, G.2
  • 4
    • 34047260251 scopus 로고    scopus 로고
    • Analysis of Tip Malposition and Correction in Peripherally Inserted Central Catheters Placed at Bedside by a Dedicated Nursing Team
    • DOI 10.1016/j.jvir.2007.01.020, PII S1051044307003405
    • Trerotola SO, Thompson S, Chittams J, Vierregger KS. Analysis of tip malposition and correction in peripherally inserted central catheters placed at bedside by a dedicated nursing team. J Vasc Interv Radiol 2007; 18:513-518. (Pubitemid 46552262)
    • (2007) Journal of Vascular and Interventional Radiology , vol.18 , Issue.4 , pp. 513-518
    • Trerotola, S.O.1    Thompson, S.2    Chittams, J.3    Vierregger, K.S.4
  • 5
    • 59849116060 scopus 로고    scopus 로고
    • Impact of different vein catheter sizes for mechanical power injection in CT: In vitro evaluation with use of a circulation phantom
    • Behrendt FF, Bruners P, Keil S, et al. Impact of different vein catheter sizes for mechanical power injection in CT: in vitro evaluation with use of a circulation phantom. Cardiovasc Intervent Radiol 2009; 32:25-31.
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 25-31
    • Behrendt, F.F.1    Bruners, P.2    Keil, S.3
  • 7
    • 73949144522 scopus 로고    scopus 로고
    • Central venous catheter integrity during mechanical power injection of iodinated contrast medium
    • Macha DB, Nelson RC, Howle LE, Hollingsworth JW, Schindera ST. Central venous catheter integrity during mechanical power injection of iodinated contrast medium. Radiol 2009; 253:870-878.
    • (2009) Radiol , vol.253 , pp. 870-878
    • Macha, D.B.1    Nelson, R.C.2    Howle, L.E.3    Hollingsworth, J.W.4    Schindera, S.T.5
  • 8
    • 0034329865 scopus 로고    scopus 로고
    • Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity
    • Forauer AR, Alonzo M. Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity. J Vasc Interv Radiol 2000; 11:1315-1318.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1315-1318
    • Forauer, A.R.1    Alonzo, M.2
  • 9
    • 0141705179 scopus 로고    scopus 로고
    • Histologic changes in the human vein wall adjacent to indwelling central venous catheters
    • Forauer AR, Theoharis C. Histologic changes in the human vein wall adjacent to indwelling central venous catheters. J Vasc Interv Radiol 2003; 14:1163-1168. (Pubitemid 37193730)
    • (2003) Journal of Vascular and Interventional Radiology , vol.14 , Issue.9 I , pp. 1163-1168
    • Forauer, A.R.1    Theoharis, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.