메뉴 건너뛰기




Volumn 53, Issue , 2012, Pages 74-82

Evaluation of the potential emissions reductions from the use of CHP systems in different commercial buildings

Author keywords

Carbon equivalent; CHP emission reduction; CHP in commercial buildings; CO 2 emission reduction

Indexed keywords

BUILDING TYPES; CARBON EQUIVALENT; CARBON EQUIVALENT EMISSION; CHICAGO; CHP EMISSION REDUCTION; CHP IN COMMERCIAL BUILDINGS; CHP-SYSTEMS; COMBINED HEATING; COMMERCIAL BUILDING; ELECTRICITY GRIDS; EMISSIONS REDUCTION; GENERATE ELECTRICITY; HARMFUL EMISSIONS; HOT WATER; ILLINOIS; OPERATIONAL COSTS; POWER PRODUCTION; PRIMARY ENERGY CONSUMPTION; REFERENCE SYSTEMS; TOTAL CARBON;

EID: 84862826856     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2012.01.006     Document Type: Article
Times cited : (72)

References (20)
  • 2
    • 75849161005 scopus 로고    scopus 로고
    • A review on energy, economical, and environmental benefits of the use of CHP systems for small commercial buildings for the north American climate
    • Mago P.J., Chamra L.M., Hueffed A. A review on energy, economical, and environmental benefits of the use of CHP systems for small commercial buildings for the north American climate. Int J Energ Res 2009, 33:1252-1265.
    • (2009) Int J Energ Res , vol.33 , pp. 1252-1265
    • Mago, P.J.1    Chamra, L.M.2    Hueffed, A.3
  • 3
    • 77955602965 scopus 로고    scopus 로고
    • Influence of prime mover size and operational strategy on the performance of combined cooling, heating, and power systems under different cost structures
    • Hueffed A.K., Mago P.J. Influence of prime mover size and operational strategy on the performance of combined cooling, heating, and power systems under different cost structures. J Power Energ 2010, 224(5):591-605.
    • (2010) J Power Energ , vol.224 , Issue.5 , pp. 591-605
    • Hueffed, A.K.1    Mago, P.J.2
  • 4
    • 68249133940 scopus 로고    scopus 로고
    • Energy and carbon emission footprint of micro-CHP systems in residential buildings of different energy demand levels
    • Dorer V., Weber A. Energy and carbon emission footprint of micro-CHP systems in residential buildings of different energy demand levels. J Build Perform Simul 2009, 2(1):31-46.
    • (2009) J Build Perform Simul , vol.2 , Issue.1 , pp. 31-46
    • Dorer, V.1    Weber, A.2
  • 5
    • 10244245021 scopus 로고    scopus 로고
    • Selection and sizing of prime movers in combined heat and power systems
    • Vienna, Austria
    • Sayane S., Shokrollahi S. Selection and sizing of prime movers in combined heat and power systems. Proceedings of ASME Turbo Expo 2004, 613-621. Vienna, Austria.
    • (2004) Proceedings of ASME Turbo Expo , pp. 613-621
    • Sayane, S.1    Shokrollahi, S.2
  • 6
    • 27344450531 scopus 로고    scopus 로고
    • Using CHP systems in commercial buildings
    • Zogg R., Roth K., Brodrick J. Using CHP systems in commercial buildings. ASHRAE J September 2005, 33-36.
    • (2005) ASHRAE J , pp. 33-36
    • Zogg, R.1    Roth, K.2    Brodrick, J.3
  • 7
    • 67649415988 scopus 로고    scopus 로고
    • Performance analysis of CCHP and CHP systems operating following the thermal and electric load
    • Mago P.J., Fumo N., Chamra L.M. Performance analysis of CCHP and CHP systems operating following the thermal and electric load. Int J Energ Res 2009, 33:852-864.
    • (2009) Int J Energ Res , vol.33 , pp. 852-864
    • Mago, P.J.1    Fumo, N.2    Chamra, L.M.3
  • 9
    • 84862812943 scopus 로고    scopus 로고
    • Analysis of combined cooling, heating, and power systems operating following the electric load and following the thermal load strategies with no electricity exporting.
    • Accepted for Publication.
    • Fumo N, Mago PJ, and Smith AD. Analysis of combined cooling, heating, and power systems operating following the electric load and following the thermal load strategies with no electricity exporting. J Power Energ. Accepted for Publication.
    • J Power Energ.
    • Fumo, N.1    Mago, P.J.2    Smith, A.D.3
  • 10
    • 84872658098 scopus 로고    scopus 로고
    • Evaluation of a base-loaded combined heating and power system with thermal storage for different small buildings applications.
    • Accepted for Publication.
    • Mago PJ and Luck R. Evaluation of a base-loaded combined heating and power system with thermal storage for different small buildings applications. Int J Energ Res. Accepted for Publication.
    • Int J Energ Res.
    • Mago, P.J.1    Luck, R.2
  • 11
    • 85011436380 scopus 로고    scopus 로고
    • Sizing CCHP Systems for variable and non-coincident loads: part 1 - load profiling and equipment selection
    • Sclafani A., Beyene A. Sizing CCHP Systems for variable and non-coincident loads: part 1 - load profiling and equipment selection. Cogen Distrib Gen J 2008, 23(3):6-19.
    • (2008) Cogen Distrib Gen J , vol.23 , Issue.3 , pp. 6-19
    • Sclafani, A.1    Beyene, A.2
  • 12
    • 13444274599 scopus 로고    scopus 로고
    • Off-design simulation and mathematical modeling of small-scale CHP plants at part loads
    • Savola T., Keppo I. Off-design simulation and mathematical modeling of small-scale CHP plants at part loads. Appl Therm Eng 2005, 25:1219-1232.
    • (2005) Appl Therm Eng , vol.25 , pp. 1219-1232
    • Savola, T.1    Keppo, I.2
  • 13
    • 84855178451 scopus 로고    scopus 로고
    • Operation of micro-CHP system using an Optimal Energy Dispatch Algorithm
    • August 10-14, Jacksonville, FL
    • Cho H., Eksioglu S., Luck R., Chamra L.M. Operation of micro-CHP system using an Optimal Energy Dispatch Algorithm. ASME Proceedings of Energy Sustainability 2008, August 10-14, Jacksonville, FL.
    • (2008) ASME Proceedings of Energy Sustainability
    • Cho, H.1    Eksioglu, S.2    Luck, R.3    Chamra, L.M.4
  • 15
    • 34547531091 scopus 로고    scopus 로고
    • Available at:, U.S.Energy Information Administration
    • U.S.Energy Information Administration Emissions of greenhouse gases in the United States 2009, Available at:. http://www.eia.doe.gov/oiaf/1605/ggrpt/pdf/0573(2008).pdf.
    • (2009) Emissions of greenhouse gases in the United States
  • 16
    • 0003405496 scopus 로고    scopus 로고
    • Available at:, U.S.Energy Information Administration
    • U.S.Energy Information Administration Annual energy review 2010, Available at:. http://www.eia.doe.gov/emeu/aer/contents.html.
    • (2010) Annual energy review
  • 17
    • 84862800099 scopus 로고    scopus 로고
    • City of Chicago Climate Task Force, 2008. Chicago Climate Action Plan. Available at:
    • City of Chicago Climate Task Force, 2008. Chicago Climate Action Plan. Available at: http://www.chicagoclimateaction.org/filebin/pdf/finalreport/CCAPREPORTFINALv2.pdf.
    • (2008)
  • 19
    • 84856411502 scopus 로고    scopus 로고
    • Available at:, U.S.Department of Energy
    • U.S.Department of Energy EnergyPlus Energy Simulation Software 2010, Available at:. http://apps1.eere.energy.gov/buildings/energyplus/.
    • (2010) EnergyPlus Energy Simulation Software


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.