메뉴 건너뛰기




Volumn 216, Issue , 2012, Pages 128-133

Transformer-coupled NMR probe

Author keywords

Inductive coupling; Matching; Probe; Transformer

Indexed keywords

DIFFUSION MEASUREMENTS; EFFICIENT ENERGY TRANSFER; FERROMAGNETIC CORES; INDUCTIVE COUPLINGS; MATCHING; MULTI FREQUENCY; NMR PROBE; NMR SPECTROMETER; TRANSFORMER; WIDE FREQUENCY RANGE;

EID: 84862824191     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2012.01.009     Document Type: Article
Times cited : (6)

References (16)
  • 3
    • 0011029504 scopus 로고
    • Inductive (flux linkage) coupling to local coils in magnetic resonance imaging and spectroscopy
    • W. Froncisz, A. Jesmanowicz, and J.S. Hyde Inductive (flux linkage) coupling to local coils in magnetic resonance imaging and spectroscopy J. Magn. Reson. 66 1986 135 143
    • (1986) J. Magn. Reson. , vol.66 , pp. 135-143
    • Froncisz, W.1    Jesmanowicz, A.2    Hyde, J.S.3
  • 5
    • 0002032504 scopus 로고
    • Inductive coupling and tuning in NMR probes: Applications
    • P.L. Kuhns, M.J. Lizak, S.H. Lee, and M.S. Conradi Inductive coupling and tuning in NMR probes: applications J. Magn. Reson. 78 1988 69 76
    • (1988) J. Magn. Reson. , vol.78 , pp. 69-76
    • Kuhns, P.L.1    Lizak, M.J.2    Lee, S.H.3    Conradi, M.S.4
  • 6
    • 18444417981 scopus 로고    scopus 로고
    • Use of mutually inductive coupling in probe design
    • D.I. Hoult, and B. Tomanek Use of mutually inductive coupling in probe design Concepts Magn. Reson. 15 2002 262 285
    • (2002) Concepts Magn. Reson. , vol.15 , pp. 262-285
    • Hoult, D.I.1    Tomanek, B.2
  • 7
    • 63349088759 scopus 로고    scopus 로고
    • Nuclear magnetic resonance in microfluidic environments using inductively coupled radiofrequency resonators
    • M. Utz, and R. Monazami Nuclear magnetic resonance in microfluidic environments using inductively coupled radiofrequency resonators J. Magn. Reson. 198 2009 132 136
    • (2009) J. Magn. Reson. , vol.198 , pp. 132-136
    • Utz, M.1    Monazami, R.2
  • 8
    • 55049131410 scopus 로고    scopus 로고
    • Inductively coupled RF coil design for simultaneous microimaging of multiple samples
    • T. Wang, L. Ciobanu, X. Zhang, and A. Webb Inductively coupled RF coil design for simultaneous microimaging of multiple samples Concepts Magn. Reson. 33B 2008 236 243
    • (2008) Concepts Magn. Reson. , vol.33 B , pp. 236-243
    • Wang, T.1    Ciobanu, L.2    Zhang, X.3    Webb, A.4
  • 9
    • 34250009350 scopus 로고    scopus 로고
    • High-resolution, high-sensitivity NMR of nanolitre anisotropic samples by coil spinning
    • DOI 10.1038/nature05897, PII NATURE05897
    • D. Sakellariou, G. Le Goff, and J.-F. Jacquinot High resolution, high sensitivity NMR of nanoliter anisotropic samples by coil spinning Nature 447 2007 694 697 (Pubitemid 46889735)
    • (2007) Nature , vol.447 , Issue.7145 , pp. 694-697
    • Sakellariou, D.1    Goff, G.L.2    Jacquinot, J.-F.3
  • 10
    • 79953124156 scopus 로고    scopus 로고
    • NMR signal detection using inductive coupling: Applications to rotating microcoils
    • J.-F. Jacquinot, and D. Sakellariou NMR signal detection using inductive coupling: applications to rotating microcoils Concepts Magn. Reson. 38A 2011 33 51
    • (2011) Concepts Magn. Reson. , vol.38 A , pp. 33-51
    • Jacquinot, J.-F.1    Sakellariou, D.2
  • 13
    • 0010799576 scopus 로고
    • Impedance: What it is, and why it must be matched
    • D.D. Traficante Impedance: what it is, and why it must be matched Concepts Magn. Reson. 1 1989 73 92
    • (1989) Concepts Magn. Reson. , vol.1 , pp. 73-92
    • Traficante, D.D.1
  • 14
    • 84985757210 scopus 로고
    • Parameterized description of NMR signal reception systems. Part I: Impedance of transmission line and probe
    • S.-I. Cho, and N.S. Sullivan Parameterized description of NMR signal reception systems. Part I: impedance of transmission line and probe Concepts Magn. Reson. 4 1992 227 243
    • (1992) Concepts Magn. Reson. , vol.4 , pp. 227-243
    • Cho, S.-I.1    Sullivan, N.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.