메뉴 건너뛰기




Volumn 59, Issue 4, 2012, Pages 424-425

A customized stylet for GlideScope® insertion of double lumen tubes

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; CLINICAL ARTICLE; DOUBLE LUMEN TUBE; ENDOSCOPE; ENDOTRACHEAL INTUBATION; HUMAN; ISOLATED ORGAN; LETTER; MEDICAL DEVICE; OUTCOME ASSESSMENT; PRIORITY JOURNAL; STYLET; THORAX SURGERY;

EID: 84862770313     PISSN: 0832610X     EISSN: 14968975     Source Type: Journal    
DOI: 10.1007/s12630-012-9671-2     Document Type: Letter
Times cited : (14)

References (5)
  • 1
    • 78650708929 scopus 로고    scopus 로고
    • Routine clinical practice effectiveness of the Glidescope in difficult airway management: An analysis of 2,004 Glidescope intubations, complications, and failures from two institutions
    • Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011; 114: 34-41.
    • (2011) Anesthesiology , vol.114 , pp. 34-41
    • Aziz, M.F.1    Healy, D.2    Kheterpal, S.3    Fu, R.F.4    Dillman, D.5    Brambrink, A.M.6
  • 2
    • 75149174729 scopus 로고    scopus 로고
    • Lung isolation techniques for patients with difficult airway
    • Campos JH. Lung isolation techniques for patients with difficult airway. Curr Opin Anaesthesiol 2010; 23: 12-7.
    • (2010) Curr Opin Anaesthesiol , vol.23 , pp. 12-17
    • Campos, J.H.1
  • 3
    • 23844456259 scopus 로고    scopus 로고
    • Using a Glidescope for intubation with a double lumen endotracheal tube [8]
    • Hernandez AA, Wong DH. Using a Glidescope for intubation with a double lumen endotracheal tube. Can J Anesth 2005; 52: 658-9. (Pubitemid 41149874)
    • (2005) Canadian Journal of Anesthesia , vol.52 , Issue.6 , pp. 658-659
    • Hernandez, A.A.1    Wong, D.H.2
  • 4
    • 38749134856 scopus 로고    scopus 로고
    • GlideScope-Assisted Double-Lumen Endobronchial Tube Placement in a Patient With an Unanticipated Difficult Airway
    • DOI 10.1053/j.jvca.2007.04.006, PII S1053077007001115
    • Chen A, Lai HY, Lin PC, Chen TY, Shyr MH. GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway. J Cardiothorac Vasc Anesth 2008; 22: 170-2. (Pubitemid 351179390)
    • (2008) Journal of Cardiothoracic and Vascular Anesthesia , vol.22 , Issue.1 , pp. 170-172
    • Chen, A.1    Lai, H.-Y.2    Lin, P.-C.3    Chen, T.-Y.4    Shyr, M.-H.5
  • 5
    • 77953285661 scopus 로고    scopus 로고
    • Sequential rotation to insert a left double-lumen endotracheal tube using the Glide-Scope
    • Bustamante S, Parra-Sanchez I, Apostolakis J. Sequential rotation to insert a left double-lumen endotracheal tube using the Glide-Scope. Can J Anesth 2010; 57: 282-3.
    • (2010) Can J Anesth , vol.57 , pp. 282-283
    • Bustamante, S.1    Parra-Sanchez, I.2    Apostolakis, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.