메뉴 건너뛰기




Volumn 3, Issue 1, 2011, Pages 24-32

HVAC control strategies for thermal comfort and indoor air quality

Author keywords

DCV; HVAC control; IAQ; Indoor air quality; Sensor based demand controlled ventilation; Thermal comfort

Indexed keywords


EID: 84862735694     PISSN: 17568412     EISSN: 17568420     Source Type: Journal    
DOI: 10.1504/IJAMECHS.2011.040160     Document Type: Conference Paper
Times cited : (5)

References (17)
  • 1
    • 0003842304 scopus 로고    scopus 로고
    • ASHRAE, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), Atlanta, GA
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) (1997) 1997 ASHRAE Handbook: Fundamentals, ASHRAE, Atlanta, GA.
    • (1997) 1997 ASHRAE Handbook: Fundamentals
  • 2
    • 0003632802 scopus 로고    scopus 로고
    • ANSI/ASHRAE Standard 55, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA
    • ANSI/ASHRAE Standard 55 (2004) Thermal Environmental Conditions for Human Occupancy, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA.
    • (2004) Thermal Environmental Conditions for Human Occupancy
  • 4
    • 2142791066 scopus 로고
    • Second generation demand-controlled ventilation
    • ASHRAE
    • Bearg, D.W. (1994)'Second generation demand-controlled ventilation', IAQ'94, ASHRAE.
    • (1994) IAQ'94
    • Bearg, D.W.1
  • 5
    • 33745845837 scopus 로고    scopus 로고
    • An innovative approach for demand side management-optimal chiller loading by simulated annealing
    • Chang, Y.C. (2006)'An innovative approach for demand side management-optimal chiller loading by simulated annealing', Energy 2006, Vol. 31, No. 12, pp.1883-1896.
    • (2006) Energy 2006 , vol.31 , Issue.12 , pp. 1883-1896
    • Chang, Y.C.1
  • 7
    • 7944221563 scopus 로고    scopus 로고
    • State-of-the-art review of CO2 demand controlled ventilation technology and application
    • March
    • Emmerich, S.J. and Persily, A.K. (2001)'State-of-the-art review of CO2 demand controlled ventilation technology and application', NISTIR 6729, March.
    • (2001) NISTIR 6729
    • Emmerich, S.J.1    Persily, A.K.2
  • 8
    • 0032305454 scopus 로고    scopus 로고
    • Sensor-based demand-controlled ventilation: A review
    • PII S0378778898000292
    • Fisk, W.J. and De Almeida, A.T. (1998)'Sensor-based demand-controlled ventilation: a review', Energy and Buildings, Vol. 29, pp.35-45. (Pubitemid 128401004)
    • (1998) Energy and Buildings , vol.29 , Issue.1 , pp. 35-45
    • Fisk, W.J.1    De Almeida, A.T.2
  • 9
    • 77949542289 scopus 로고    scopus 로고
    • Optimal decision making in ventilation control
    • Kusiak, A. and Li, M. (2009)'Optimal decision making in ventilation control', Journal of Energy and Building, Vol. 34, pp.1835-1845.
    • (2009) Journal of Energy and Building , vol.34 , pp. 1835-1845
    • Kusiak, A.1    Li, M.2
  • 11
    • 67749104667 scopus 로고    scopus 로고
    • Indoor thermal factors and symptoms in office workers: Findings from the US EPA BASE study
    • 13 March
    • Mendell, M.J. and Mirer, A.G. (2009)'Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study', Indoor Air 2009, 13 March.
    • (2009) Indoor Air 2009
    • Mendell, M.J.1    Mirer, A.G.2
  • 12
    • 57449101464 scopus 로고    scopus 로고
    • Optimal control strategy for a multi-zone air conditioning system using a genetic algorithm
    • Mossolly, M., Ghali, K. and Ghaddar, N. (2009)'Optimal control strategy for a multi-zone air conditioning system using a genetic algorithm', Energy 2009, Vol. 34, No. 1, pp.58-66.
    • (2009) Energy 2009 , vol.34 , Issue.1 , pp. 58-66
    • Mossolly, M.1    Ghali, K.2    Ghaddar, N.3
  • 13
    • 37349005232 scopus 로고    scopus 로고
    • Flow patterns and thermal comfort in a room with panel, floor and wall heating
    • DOI 10.1016/j.enbuild.2007.04.011, PII S0378778807001351
    • Myhren, J.A. and Holmberg, S. (2008)'Flow patterns and thermal comfort in a room with panel, floor and wall heating', Energy and Buildings, Vol. 40, No. 4, pp.524-536. (Pubitemid 350296692)
    • (2008) Energy and Buildings , vol.40 , Issue.4 , pp. 524-536
    • Myhren, J.A.1    Holmberg, S.2
  • 17
    • 0025750428 scopus 로고
    • 2 concentration. A comparison of simulated energy savings in an auditorium space
    • DOI 10.1016/0378-7788(91)90001-J
    • Warren, B.F. and Harper, N.C. (1991)'Demand controlled ventilation by room carbon dioxide concentration: a comparison simulated energy savings in an auditorium space', Energy Building, Vol. 17, pp.87-96. (Pubitemid 21708633)
    • (1991) Energy and Buildings , vol.17 , Issue.2 , pp. 87-96
    • Warren, B.F.1    Harper, N.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.