메뉴 건너뛰기




Volumn 57, Issue 13, 2012, Pages 4277-4292

Auto-masked 2D/3D image registration and its validation with clinical cone-beam computed tomography

Author keywords

[No Author keywords available]

Indexed keywords

2D/3D REGISTRATION; 3D SEGMENTATION; COMPUTED TOMOGRAPHY; CONE-BEAM COMPUTED TOMOGRAPHY; CONEBEAM CT; DATA SETS; ERROR RANGE; IMAGE-GUIDED; PARAMETRIC ERRORS; PATIENT SETUP; PIXEL INTENSITIES; PRE-PLANNING; RANK CORRELATION; RECONSTRUCTED RADIOGRAPHS; REGIONS OF INTEREST; ROOT MEAN SQUARE; TARGET REGISTRATION ERRORS; TREATMENT PRESCRIPTION;

EID: 84862734524     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/13/4277     Document Type: Article
Times cited : (17)

References (29)
  • 1
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • 10.1148/rg.246045065 0271-5333
    • Barrett J F and Keat N 2004 Artifacts in CT: recognition and avoidance Radiographics 24 167991
    • (2004) Radiographics , vol.24 , Issue.6 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 2
    • 77950341204 scopus 로고    scopus 로고
    • 6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac x-ray 6D with kilo-voltage cone-beam CT
    • 10.1016/j.radonc.2009.12.036 0167-8140
    • Chang Z, Wang Z, Ma J, Daniel J C, Kirkpatrick J and Yin F F 2010 6D image guidance for spinal non-invasive stereotactic body radiation therapy: comparison between ExacTrac x-ray 6D with kilo-voltage cone-beam CT Radiother. Oncol. 95 11621
    • (2010) Radiother. Oncol. , vol.95 , Issue.1 , pp. 116-121
    • Chang, Z.1    Wang, Z.2    Ma, J.3    Daniel, J.C.4    Kirkpatrick, J.5    Yin, F.F.6
  • 3
    • 33646237120 scopus 로고    scopus 로고
    • A gradient feature weighted minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy
    • 10.1016/j.ijrobp.2005.12.032 0360-3016
    • Chelikani S, Purushothaman K, Knisely J, Chen Z, Nath R, Bansal R and Duncan J 2006 A gradient feature weighted minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 65 53547
    • (2006) Int. J. Radiat. Oncol. Biol. Phys. , vol.65 , Issue.2 , pp. 535-547
    • Chelikani, S.1    Purushothaman, K.2    Knisely, J.3    Chen, Z.4    Nath, R.5    Bansal, R.6    Duncan, J.7
  • 4
    • 39049110013 scopus 로고    scopus 로고
    • A computationally efficient method for automatic registration of orthogonal x-ray images with volumetric CT data
    • DOI 10.1088/0031-9155/53/4/010, PII S0031915508513315
    • Chen X, Varley M R, Shark L K, Shentall G S and Kirby M C 2008 A computationally efficient method for automatic registration of orthogonal x-ray images with volumetric CT data Phys. Med. Biol. 53 96783 (Pubitemid 351238117)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.4 , pp. 967-983
    • Chen, X.1    Varley, M.R.2    Shark, L.-K.3    Shentall, G.S.4    Kirby, M.C.5
  • 5
    • 79954418721 scopus 로고    scopus 로고
    • Evaluation of radiation dose and image quality for the Varian cone beam computed tomography system
    • 10.1016/j.ijrobp.2010.06.014 0360-3016
    • Cheng H C Y, Wu V W C, Liu E S F and Kwong D L W 2011 Evaluation of radiation dose and image quality for the Varian cone beam computed tomography system Int. J. Radiat. Oncol. Biol. Phys. 80 291300
    • (2011) Int. J. Radiat. Oncol. Biol. Phys. , vol.80 , Issue.1 , pp. 291-300
    • Cheng, H.C.Y.1    Wu, V.W.C.2    Liu, E.S.F.3    Kwong, D.L.W.4
  • 6
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • DOI 10.1118/1.1869652
    • Cho Y, Moseley D J, Siewerdsen J H and Jaffray D A 2005 Accurate technique for complete geometric calibration of cone-beam computed tomography systems Med. Phys. 32 96883 (Pubitemid 40586782)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 7
    • 84862740171 scopus 로고    scopus 로고
    • First clinical release of an online, adaptive, aperture-based image-guided radiotherapy strategy in intensity-modulated radiotherapy to correct for inter- and intrafractional rotations of the prostate
    • 0360-3016
    • Deutschmann H et al 2012 First clinical release of an online, adaptive, aperture-based image-guided radiotherapy strategy in intensity-modulated radiotherapy to correct for inter- and intrafractional rotations of the prostate Int. J. Radiat. Oncol. Biol. Phys. at press (doi: 10.1016/j.ijrobp.2011.10.009)
    • (2012) Int. J. Radiat. Oncol. Biol. Phys.
    • Deutschmann, H.1
  • 11
  • 12
    • 77249134524 scopus 로고    scopus 로고
    • The European society of therapeutic radiology and oncology-european institute of radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: A practical and technical review and guide
    • 10.1016/j.radonc.2010.01.004 0167-8140
    • Korreman S, Rasch C, McNair H, Verellen D, Oelfke U, Maingon P, Mijnheer B and Khoo V 2010 The European society of therapeutic radiology and oncology-european institute of radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide Radiother. Oncol. 94 12944
    • (2010) Radiother. Oncol. , vol.94 , Issue.2 , pp. 129-144
    • Korreman, S.1    Rasch, C.2    McNair, H.3    Verellen, D.4    Oelfke, U.5    Maingon, P.6    Mijnheer, B.7    Khoo, V.8
  • 13
    • 84857628623 scopus 로고    scopus 로고
    • A review of 3D/2D registration methods for image-guided interventions
    • 10.1016/j.media.2010.03.005 1361-8415
    • Markelj P, Tomaevi D, Likar B and Pernu F 2010 A review of 3D/2D registration methods for image-guided interventions Med. Image Anal. 16 64261
    • (2010) Med. Image Anal. , vol.16 , Issue.3 , pp. 642-661
    • Markelj, P.1    Tomaevi, D.2    Likar, B.3    Pernu, F.4
  • 14
  • 15
    • 70349678712 scopus 로고    scopus 로고
    • 2D3D registration for prostate radiation therapy based on a statistical model of transmission images
    • 10.1118/1.3213531 0094-2405
    • Munbodh R, Tagare H D, Chen Z, Jaffray D A, Moseley D J, Knisely J P S and Duncan J S 2009 2D3D registration for prostate radiation therapy based on a statistical model of transmission images Med. Phys. 36 455568
    • (2009) Med. Phys. , vol.36 , Issue.10 , pp. 4555-4568
    • Munbodh, R.1    Tagare, H.D.2    Chen, Z.3    Jaffray, D.A.4    Moseley, D.J.5    Knisely, J.P.S.6    Duncan, J.S.7
  • 16
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • 0010-4620
    • Nelder J A and Mead R 1965 A simplex method for function minimization Comput. J. 7 30813
    • (1965) Comput. J. , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2
  • 18
    • 46149110088 scopus 로고    scopus 로고
    • A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map
    • DOI 10.1118/1.2940725
    • Ren L, Zhang J, Thongphiew D, Godfrey D J, Wu Q J, Zhou S M and Yin F F 2008 A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map Med. Phys. 35 31105 (Pubitemid 351904515)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3110-3115
    • Ren, L.1    Zhang, J.2    Thongphiew, D.3    Godfrey, D.J.4    Jackie Wu, Q.5    Zhou, S.-M.6    Yin, F.-F.7
  • 20
    • 52049117425 scopus 로고    scopus 로고
    • What is cone-beam CT and how does it work?
    • 10.1016/j.cden.2008.05.005 0011-8532
    • Scarfe W C and Farman A G 2008 What is cone-beam CT and how does it work? Dental Clin. North Am. 52 70730
    • (2008) Dental Clin. North Am. , vol.52 , Issue.4 , pp. 707-730
    • Scarfe, W.C.1    Farman, A.G.2
  • 22
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • DOI 10.1118/1.1836331
    • Siewerdsen J H, Moseley D J, Burch S, Bisland S K, Bogaards A, Wilson B C and Jaffray D A 2005 Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery Med. Phys. 32 24154 (Pubitemid 40165536)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3    Bisland, S.K.4    Bogaards, A.5    Wilson, B.C.6    Jaffray, D.A.7
  • 23
    • 71949109614 scopus 로고    scopus 로고
    • Investigation of uncertainties in image registration of cone beam CT to CT on an image-guided radiotherapy system
    • 10.1088/0031-9155/54/24/002 0031-9155
    • Sykes J R, Brettle D S, Magee D R and Thwaites D I 2009 Investigation of uncertainties in image registration of cone beam CT to CT on an image-guided radiotherapy system Phys. Med. Biol. 54 7263
    • (2009) Phys. Med. Biol. , vol.54 , Issue.24 , pp. 7263
    • Sykes, J.R.1    Brettle, D.S.2    Magee, D.R.3    Thwaites, D.I.4
  • 24
    • 33750441477 scopus 로고    scopus 로고
    • Correction of patient positioning errors based on in-line cone beam CTs: Clinical implementation and first experiences
    • 10.1186/1748-717X-1-16 1748-717X
    • Thilmann C et al 2006 Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences Radiat. Oncol. 1 16
    • (2006) Radiat. Oncol. , vol.1 , Issue.1 , pp. 16
    • Thilmann, C.1
  • 25
    • 80052667571 scopus 로고    scopus 로고
    • Low-dose CT reconstruction via edge-preserving total variation regularization
    • 10.1088/0031-9155/56/18/011 0031-9155
    • Tian Z, Jia X, Yuan K, Pan T and Jiang S B 2011 Low-dose CT reconstruction via edge-preserving total variation regularization Phys. Med. Biol. 56 5949
    • (2011) Phys. Med. Biol. , vol.56 , Issue.18 , pp. 5949
    • Tian, Z.1    Jia, X.2    Yuan, K.3    Pan, T.4    Jiang, S.B.5
  • 27
    • 45749103203 scopus 로고    scopus 로고
    • Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
    • DOI 10.1088/0031-9155/53/11/009, PII S0031915508683785
    • Wang J, Li T, Liang Z and Xing L 2008 Dose reduction for kilovoltage cone-beam computed tomography in radiation therapy Phys. Med. Biol. 53 2897 (Pubitemid 351868612)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2897-2909
    • Wang, J.1    Li, T.2    Liang, Z.3    Xing, L.4
  • 28
    • 72049102100 scopus 로고    scopus 로고
    • Evaluation of similarity measures for use in the intensity-based rigid 2D3D registration for patient positioning in radiotherapy
    • 10.1118/1.3250843 0094-2405
    • Wu J, Kim M, Peters J, Chung H and Samant S S 2009 Evaluation of similarity measures for use in the intensity-based rigid 2D3D registration for patient positioning in radiotherapy Med. Phys. 36 5391403
    • (2009) Med. Phys. , vol.36 , Issue.12 , pp. 5391-5403
    • Wu, J.1    Kim, M.2    Peters, J.3    Chung, H.4    Samant, S.S.5
  • 29
    • 79961128903 scopus 로고    scopus 로고
    • A phantom study on target localization accuracy using cone-beam computed tomography
    • Yan H, Zhang L and Yin F 2008 A phantom study on target localization accuracy using cone-beam computed tomography Clin. Med. Oncol. 2 50110
    • (2008) Clin. Med. Oncol. , vol.2 , pp. 501-510
    • Yan, H.1    Zhang, L.2    Yin, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.