메뉴 건너뛰기




Volumn 55, Issue 4, 2012, Pages 515-523

Development and characterization of a microfluidic glucose sensing system based on an enzymatic microreactor and chemiluminescence detection

Author keywords

Chaotic mixing; Chemiluminescence; Enzymatic microreactor; Glucose sensing system; Microfluidic chip

Indexed keywords

AMPEROMETRIC DETECTION; APPLIED POTENTIALS; ASCORBIC ACIDS; CHAOTIC MIXING; CHEMILUMINESCENCE DETECTION; CHEMILUMINESCENCE REACTIONS; CONTINUOUS GLUCOSE MONITORING; CURRENT RESPONSE; DIRECT CONTACT; ELECTRODE FOULING; ENZYMATIC CONVERSIONS; FABRICATED CHIPS; GLUCOSE ANALYSIS; GLUCOSE CONCENTRATION; GLUCOSE MEASUREMENTS; GLUCOSE SENSING SYSTEMS; HORSE-RADISH PEROXIDASE; LIMIT OF DETECTION; LINEAR CALIBRATION CURVE; LUMINOLS; MICRO-FLOW; MICRO-FLUIDIC DEVICES; MICRO-REACTOR; MICROFLUIDIC CHIP; OPTIMAL REACTION CONDITION; REPRODUCIBILITIES; SIGNAL DRIFT; SILICON PHOTODIODE; URIC ACIDS;

EID: 84862690404     PISSN: 16747291     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11426-012-4557-2     Document Type: Article
Times cited : (14)

References (34)
  • 2
    • 77953571969 scopus 로고    scopus 로고
    • Latest developments in microfluidic cell biology and analysis systems
    • Salieb-Beugelaar GB, Simone G, Arora A, Philippi A, Manz A. Latest developments in microfluidic cell biology and analysis systems. Anal Chem, 2010, 82(12): 4848-4864
    • (2010) Anal Chem , vol.82 , Issue.12 , pp. 4848-4864
    • Salieb-Beugelaar, G.B.1    Simone, G.2    Arora, A.3    Philippi, A.4    Manz, A.5
  • 4
    • 1942426483 scopus 로고    scopus 로고
    • Chip vision-optics for microchips
    • Verpoorte E. Chip vision-optics for microchips. Lab Chip, 2003, 3(3): 42N-52N
    • (2003) Lab Chip , vol.3 , Issue.3
    • Verpoorte, E.1
  • 5
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • DOI 10.1002/elps.200305584
    • Sia SK, Whitesides GM. Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies. Electrophoresis, 2003, 24(21): 3563-3576 (Pubitemid 38089159)
    • (2003) Electrophoresis , vol.24 , Issue.21 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2
  • 6
    • 34848830411 scopus 로고    scopus 로고
    • Optical sensing systems for microfluidic devices: A review
    • DOI 10.1016/j.aca.2007.08.046, PII S0003267007014444
    • Kuswandi B, Nuriman HJ, Verboom W. Optical sensing systems for microfluidic devices: A review. Anal Chim Acta, 2007, 601(2): 141-155 (Pubitemid 47505229)
    • (2007) Analytica Chimica Acta , vol.601 , Issue.2 , pp. 141-155
    • Kuswandi, B.1    Nuriman, H.J.2    Verboom, W.3
  • 7
    • 14744269439 scopus 로고    scopus 로고
    • High-throughput nanoliter sample introduction microfluidic chip-based flow injection analysis system with gravity-driven flows
    • DOI 10.1021/ac048675y
    • Du WB, Fang Q, He QH, Fang ZL. High-throughput nanoliter sample introduction microfluidic chip-based flow injection analysis system with gravity-driven flows. Anal Chem, 2005, 77(5): 1330-1337 (Pubitemid 40327872)
    • (2005) Analytical Chemistry , vol.77 , Issue.5 , pp. 1330-1337
    • Du, W.-B.1    Fang, Q.2    He, Q.-H.3    Fang, Z.-L.4
  • 9
    • 10944231321 scopus 로고    scopus 로고
    • Fundamentals and practice for ultrasensitive laser-induced fluorescence detection in microanalytical systems
    • DOI 10.1002/elps.200406086
    • Johnson ME, Landers JP. Fundamentals and practice for ultrasensitive laser-induced fluorescence detection in microanalytical systems. Electrophoresis, 2004, 25(21-22): 3513-3527 (Pubitemid 40012110)
    • (2004) Electrophoresis , vol.25 , Issue.21-22 , pp. 3513-3527
    • Johnson, M.E.1    Landers, J.P.2
  • 10
    • 30644476531 scopus 로고    scopus 로고
    • The use of a micropump based on capillary and evaporation effects in a microfluidic flow injection chemiluminescence system
    • DOI 10.1016/j.talanta.2005.08.021, PII S003991400500490X
    • Guan YX, Xu ZR, Dai J, Fang ZL. The use of a micropump based on capillary and evaporation effects in a microfluidic flow injection chemiluminescence system. Talanta, 2006, 68(4): 1384-1389 (Pubitemid 43088716)
    • (2006) Talanta , vol.68 , Issue.4 , pp. 1384-1389
    • Guan, Y.-X.1    Xu, Z.-R.2    Dai, J.3    Fang, Z.-L.4
  • 12
    • 23444448453 scopus 로고    scopus 로고
    • Determination of hydrogen peroxide in rainwater in a miniaturised analytical system
    • DOI 10.1016/j.aca.2005.05.065, PII S0003267005009505
    • Marle L, Greenway GM. Determination of hydrogen peroxide in rainwater in a miniaturised analytical system. Anal Chim Acta, 2005, 548(1-2): 20-25 (Pubitemid 41112244)
    • (2005) Analytica Chimica Acta , vol.548 , Issue.1-2 , pp. 20-25
    • Marle, L.1    Greenway, G.M.2
  • 13
    • 1242351494 scopus 로고    scopus 로고
    • Composite poly(dimethylsiloxane)/glass microfluidic system with an immobilized enzymatic particle-bed reactor and sequential sample injection for chemiluminescence determinations
    • Xu ZR, Fang ZL. Composite poly(dimethylsiloxane)/glass microfluidic system with an immobilized enzymatic particle-bed reactor and sequential sample injection for chemiluminescence determinations. Anal Chim Acta, 2004, 507(1): 129-135
    • (2004) Anal Chim Acta , vol.507 , Issue.1 , pp. 129-135
    • Xu, Z.R.1    Fang, Z.L.2
  • 14
    • 7944223971 scopus 로고    scopus 로고
    • Microfluidic biosensing systems part I. Development and optimisation of enzymatic chemiluminescent x-biosensors based on silicon microchips
    • DOI 10.1039/b400894d
    • Davidsson R, Genin F, Bengtsson M, Laurell T, Emneus J. Microfluidic biosensing systems-Part I. development and optimisation of enzymatic chemiluminescent x-biosensors based on silicon microchips. Lab Chip, 2004, 4(5): 481-487 (Pubitemid 39468921)
    • (2004) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.4 , Issue.5 , pp. 481-487
    • Davidsson, R.1    Genin, F.2    Bengtsson, M.3    Laurell, T.4    Emneus, J.5
  • 15
    • 0035461805 scopus 로고    scopus 로고
    • Effect of the geometry of microfabricated flow reactors on chemiluminescent detection of epinephrine with lucigenin
    • DOI 10.1002/bio.665
    • Kamidate T, Kaide T, Tani H, Makino E, Shibata T. Effect of the geometry of microfabricated flow reactors on chemiluminescent detection of epinephrine with lucigenin. Luminescence, 2001, 16(5): 337-342 (Pubitemid 33624877)
    • (2001) Luminescence , vol.16 , Issue.5 , pp. 337-342
    • Kamidate, T.1    Kaide, T.2    Tani, H.3    Makino, E.4    Shibata, T.5
  • 16
    • 0037457525 scopus 로고    scopus 로고
    • A biochemical microdevice with an integrated chemiluminescence detector
    • Jorgensen AM, Mogensen KB, Kutter JP, Geschke O. A biochemical microdevice with an integrated chemiluminescence detector. Sens Actuators B, 2003, 90(1-3): 15-21
    • (2003) Sens Actuators B , vol.90 , Issue.1-3 , pp. 15-21
    • Jorgensen, A.M.1    Mogensen, K.B.2    Kutter, J.P.3    Geschke, O.4
  • 19
    • 0035863679 scopus 로고    scopus 로고
    • A compactly integrated flow cell with a chemiluminescent FIA system for determining lactate concentration in serum
    • DOI 10.1021/ac000855u
    • Nakamura H, Murakami Y, Yokoyama K, Tamiya E, Karube I, Suda M, Uchiyama S. A compactly integrated flow cell with a chemilumi-nescent FIA system for determining lactate concentration in serum. Anal Chem, 2001, 73(2): 373-378 (Pubitemid 32061854)
    • (2001) Analytical Chemistry , vol.73 , Issue.2 , pp. 373-378
    • Nakamura, H.1    Murakami, Y.2    Yokoyama, K.3    Tamiya, E.4    Karube, I.5    Suda, M.6    Uchiyama, S.7
  • 22
    • 77955647233 scopus 로고    scopus 로고
    • An enzymatic microreactor based on chaotic micromixing for enhanced amperometric detection in a continuous glucose monitoring application
    • Moon B-U, Koster S, Wientjes KJC, Kwapiszewski RM, Schoonen AJM, Westerink BHC, Verpoorte E. An enzymatic microreactor based on chaotic micromixing for enhanced amperometric detection in a continuous glucose monitoring application. Anal Chem, 2010, 82(16): 6756-6763
    • (2010) Anal Chem , vol.82 , Issue.16 , pp. 6756-6763
    • Moon, B.-U.1    Koster, S.2    Wientjes, K.J.C.3    Kwapiszewski, R.M.4    Schoonen, A.J.M.5    Westerink, B.H.C.6    Verpoorte, E.7
  • 23
    • 0028080932 scopus 로고
    • Determination of hydrogen peroxide in sea water by flow-injection analysis with chemiluminescence detection
    • DOI 10.1016/0003-2670(94)90050-7
    • Price D, Worsfold PJ, Fauzi R, Mantoura C. Determination of hydrogen peroxide in sea water by flow-injection analysis with chemiluminescence detection. Anal Chim Acta, 1994, 298(1): 121-128 (Pubitemid 24336751)
    • (1994) Analytica Chimica Acta , vol.298 , Issue.1 , pp. 121-128
    • Price, D.1    Worsfold, P.J.2    Fauzi, R.3    Mantoura, C.4
  • 24
    • 33846159132 scopus 로고    scopus 로고
    • Hybridization of DNA to bead-immobilized probes confined within a microfluidic channel
    • DOI 10.1021/la0616956
    • Kim J, Heo J, Crooks RM. Hybridization of DNA to bead-immobilized probes confined within a microfluidic channel. Langmuir, 2006, 22(24): 10130-10134 (Pubitemid 46079295)
    • (2006) Langmuir , vol.22 , Issue.24 , pp. 10130-10134
    • Kim, J.1    Heo, J.2    Crooks, R.M.3
  • 25
    • 0026566537 scopus 로고
    • In vivo calibration of micro-dialysis probes for exogenous compounds
    • Menacherry S, Hubert W, Justice JB. In vivo calibration of micro-dialysis probes for exogenous compounds. Anal Chem, 1992, 64(6): 577-583
    • (1992) Anal Chem , vol.64 , Issue.6 , pp. 577-583
    • Menacherry, S.1    Hubert, W.2    Justice, J.B.3
  • 27
    • 0030576667 scopus 로고    scopus 로고
    • Highly sensitive chemiluminescence flow injection analysis system using microbial peroxidase and a photodiode detector
    • DOI 10.1016/0003-2670(96)00125-0
    • Hayashi K, Sasaki S, Ikebukuro K, Karube I. Highly sensitive chem-iluminescence flow injection analysis system using microbial per-oxidase and a photodiode detector. Anal Chim Acta, 1996, 329(1-2): 127-134 (Pubitemid 26254984)
    • (1996) Analytica Chimica Acta , vol.329 , Issue.1-2 , pp. 127-134
    • Hayashi, K.1    Sasaki, S.2    Ikebukuro, K.3    Karube, I.4
  • 28
    • 0037201686 scopus 로고    scopus 로고
    • Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose
    • DOI 10.1016/S0165-0270(02)00170-X, PII S016502700200170X
    • Dixon BM, Lowry JP, O'Neill RD. Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose. J Neurosci Methods, 2002, 119(2): 135-142 (Pubitemid 35286979)
    • (2002) Journal of Neuroscience Methods , vol.119 , Issue.2 , pp. 135-142
    • Dixon, B.M.1    Lowry, J.P.2    O'Neill, R.D.3
  • 29
    • 0034902195 scopus 로고    scopus 로고
    • A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors
    • DOI 10.1016/S0956-5663(01)00153-1, PII S0956566301001531
    • Böhm S, Pijanowska D, Olthuis W, Bergveld P. A flow-through am-perometric sensor based on dialysis tubing and free enzyme reactors. Biosens Bioelectron, 2001, 16(6): 391-397 (Pubitemid 32728161)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.6 , pp. 391-397
    • Bohm, S.1    Pijanowska, D.2    Olthuis, W.3    Bergveld, P.4
  • 30
    • 0029256760 scopus 로고
    • Silicon wafer integrated enzyme reactors
    • Laurell T, Drott J, Rosengren L. Silicon wafer integrated enzyme reactors. Biosens Bioelectron, 1995, 10(3-4): 289-299
    • (1995) Biosens Bioelectron , vol.10 , Issue.3-4 , pp. 289-299
    • Laurell, T.1    Drott, J.2    Rosengren, L.3
  • 31
    • 0041592733 scopus 로고    scopus 로고
    • Hypoglycemia in diabetes
    • DOI 10.2337/diacare.26.6.1902
    • Cryer PE, Davis SN, Shamoon H. Hypoglycemia in diabetes. Diabetes Care, 2003, 26(6): 1902-1912 (Pubitemid 36929141)
    • (2003) Diabetes Care , vol.26 , Issue.6 , pp. 1902-1912
    • Cryer, P.E.1    Davis, S.N.2    Shamoon, H.3
  • 32
    • 27644433987 scopus 로고    scopus 로고
    • Activity and storage stability of immobilized glucose oxidase onto magnesium silicate
    • DOI 10.1016/j.molcatb.2005.07.001
    • Ozyilmaz G, Tukel SS, Alptekin O. Activity and storage stability of immobilized glucose oxidase onto magnesium silicate. J Mol Catal B: Enzym, 2005, 35(4-6): 154-160 (Pubitemid 41557498)
    • (2005) Journal of Molecular Catalysis B: Enzymatic , vol.35 , Issue.4-6 , pp. 154-160
    • Ozyilmaz, G.1    Tukel, S.S.2    Alptekin, O.3
  • 33
    • 0030870032 scopus 로고    scopus 로고
    • A flow injection microdialysis sampling chemiluminescence system for in vivo on-line monitoring of glucose in intravenous and subcutaneous tissue fluid microdialy-sates
    • Fang Q, Shi XT, Sun YQ, Fang ZL. A flow injection microdialysis sampling chemiluminescence system for in vivo on-line monitoring of glucose in intravenous and subcutaneous tissue fluid microdialy-sates. Anal Chem, 1997, 69(17): 3570-3577
    • (1997) Anal Chem , vol.69 , Issue.17 , pp. 3570-3577
    • Fang, Q.1    Shi, X.T.2    Sun, Y.Q.3    Fang, Z.L.4
  • 34
    • 17744370354 scopus 로고    scopus 로고
    • Droplet-based micro-flow chemiluminescence system for in vivo glucose determination by microdialysis sampling
    • DOI 10.2116/analsci.21.413
    • Liu W, Zhang ZJ, Liu HS. Droplet-based micro-flow chemilumines-cence system for in vivo glucose determination by microdialysis sampling. Anal Sci, 2005, 21(4): 413-416 (Pubitemid 40579840)
    • (2005) Analytical Sciences , vol.21 , Issue.4 , pp. 413-416
    • Liu, W.1    Zhang, Z.2    Liu, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.