메뉴 건너뛰기




Volumn 19, Issue 3, 2012, Pages 947-954

Insulation performance of three types of micro-defects in inner epoxy insulators

Author keywords

crack; delamination; dielectric performance; Gas insulated switchgear (GIS); insulator; micro defect; partial discharge; void

Indexed keywords

DIELECTRIC PERFORMANCE; GAS INSULATED SWITCHGEARS; INSULATOR; MICRO-DEFECTS; VOID;

EID: 84862653092     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2012.6215098     Document Type: Article
Times cited : (68)

References (25)
  • 4
    • 0028410148 scopus 로고
    • Assessing the risk of failure due to particle contamination of GIS using the UHF technique
    • A. G. Sellars, O. Farish, and B. F. Hampton, "Assessing the risk of failure due to particle contamination of GIS using the UHF technique", IEEE Trans. Dielectr. Electr. Insul., Vol. 1, No.2, pp. 323-331, 1994.
    • (1994) IEEE Trans. Dielectr. Electr. Insul. , vol.1 , Issue.2 , pp. 323-331
    • Sellars, A.G.1    Farish, O.2    Hampton, B.F.3
  • 7
    • 23944456100 scopus 로고    scopus 로고
    • A unique sensitivity verification combined with real-time partial discharge identification method
    • T. Hoshino, S. Maruyama, K. Nojima, and M. Hanai, "A unique sensitivity verification combined with real-time partial discharge identification method", IEEE Trans. Power Delivery, Vol. 20, No.3, pp. 1890-1895, 2005.
    • (2005) IEEE Trans. Power Delivery , vol.20 , Issue.3 , pp. 1890-1895
    • Hoshino, T.1    Maruyama, S.2    Nojima, K.3    Hanai, M.4
  • 8
    • 78649997673 scopus 로고    scopus 로고
    • Influence of disconnecting part on propagation properties of PD-induced electromagnetic wave in model GIS
    • M. Hikita, S. Ohtsuka, S. Okabe, J. Wada, T. Hoshino, and S. Maruyama, "Influence of Disconnecting Part on Propagation Properties of PD-induced Electromagnetic Wave in Model GIS", IEEE Trans. Dielectr. Electr. Insul., Vol. 17, pp. 1731-1737, 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul. , vol.17 , pp. 1731-1737
    • Hikita, M.1    Ohtsuka, S.2    Okabe, S.3    Wada, J.4    Hoshino, T.5    Maruyama, S.6
  • 10
    • 0029356842 scopus 로고
    • A generalized approach to partial discharge modeling
    • L. Niemeyer, "A Generalized Approach to Partial Discharge Modeling", IEEE Trans. Dielectr. Electr. Insul., Vol. 2, pp. 510-528, 1995.
    • (1995) IEEE Trans. Dielectr. Electr. Insul. , vol.2 , pp. 510-528
    • Niemeyer, L.1
  • 13
    • 84862677692 scopus 로고
    • Theoretical analysis and experiments on the internal discharge in spherical void that exists in solid dielectrics
    • in Japanese
    • T. Yasui and Y. Yamada, "Theoretical analysis and experiments on the internal discharge in spherical void that exists in solid dielectrics", Trans. Sumitomo-denki, No.94, pp. 36-50, 1966 (in Japanese).
    • (1966) Trans. Sumitomo-denki, No.94 , pp. 36-50
    • Yasui, T.1    Yamada, Y.2
  • 14
    • 84862676664 scopus 로고
    • Tree growth in epoxy resin at the final stage of internal partial discharge degradation
    • in Japanese
    • Y. Kitamura and S. Hirabayashi, "Tree growth in epoxy resin at the final stage of internal partial discharge degradation", IEEJ Trans., Vol. 104-A, No.10, pp. 561-568, 1984 (in Japanese).
    • (1984) IEEJ Trans. , vol.104 A , Issue.10 , pp. 561-568
    • Kitamura, Y.1    Hirabayashi, S.2
  • 16
    • 84985833821 scopus 로고
    • Computation of electric field by surface charge method in complex insulation system
    • in Japanese
    • Y. Shibuya, M. Yasuda, S. Hayashi and M. Takechi, "Computation of Electric Field by Surface Charge Method in Complex Insulation System", IEEJ Trans., Vol. 99-A, No.5, pp. 200-206, 1979. (in Japanese)
    • (1979) IEEJ Trans. , vol.99 A , Issue.5 , pp. 200-206
    • Shibuya, Y.1    Yasuda, M.2    Hayashi, S.3    Takechi, M.4
  • 17
    • 84862703028 scopus 로고    scopus 로고
    • Effect of X-Ray irradiation on partial discharge inception for a void in insulating materials
    • in Japanese
    • O. Usui, T. Hasegawa, and H. Fujii, "Effect of X-Ray irradiation on partial discharge inception for a void in insulating materials", IEEJ Trans., ED-96-87 DEI-96-52, pp. 75-84, 1996 (in Japanese).
    • (1996) IEEJ Trans., ED-96-87 DEI-96-52 , pp. 75-84
    • Usui, O.1    Hasegawa, T.2    Fujii, H.3
  • 18
    • 0026618713 scopus 로고
    • Partial discharge part X: PD in gas insulated substations-measurement and practical consideration
    • R. Baumagartner, B. Fruth, W. Lanz, and K. Pettersson, "Partial discharge part X: PD in gas insulated substations-measurement and practical consideration", IEEE Electr. Insul. Mag., Vol. 8, No.1, pp. 16-27, 1992.
    • (1992) IEEE Electr. Insul. Mag. , vol.8 , Issue.1 , pp. 16-27
    • Baumagartner, R.1    Fruth, B.2    Lanz, W.3    Pettersson, K.4
  • 19
    • 84862650703 scopus 로고    scopus 로고
    • V-t characteristics of gas insulating spacer model for sustained AC voltage
    • in Japanese
    • H. Aoyagi, Y. Taniguchi, T. Iida, and I. Ichikawa, "V-t characteristics of Gas Insulating Spacer Model for Sustained AC Voltage", IEEJ Trans., Vol. 117-B, No.2, pp. 210-215, 1997 (in Japanese).
    • (1997) IEEJ Trans. , vol.117 B , Issue.2 , pp. 210-215
    • Aoyagi, H.1    Taniguchi, Y.2    Iida, T.3    Ichikawa, I.4
  • 22
    • 84862646725 scopus 로고
    • in Japanese
    • Discharge Handbook, IEEJ, pp. 475-477, 1974 (in Japanese).
    • (1974) Discharge Handbook, IEEJ , pp. 475-477
  • 25
    • 0012586744 scopus 로고
    • Cycle-mean fai-q characteristics of partial discharge in six electrode systems
    • in Japanese
    • T. Okamoto and T. Tanaka, "Cycle-mean fai-q characteristics of partial discharge in six electrode systems", IEEJ Trans., Vol. 102-A, No.7, pp. 381-388, 1982 (in Japanese).
    • (1982) IEEJ Trans. , vol.102 A , Issue.7 , pp. 381-388
    • Okamoto, T.1    Tanaka, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.