메뉴 건너뛰기




Volumn 61, Issue 4, 2012, Pages 310-319

Zeitfaktorencomparison of ready-to-use devices for emergency cricothyrotomy. Randomized and controlled feasibility study on a mannequin;Vergleich von fertigsets zur koniotomie: Randomisierte und kontrollierte anwendungsstudie am halsphantom

Author keywords

Airway management; Emergency medicine; Equipment design; Time factors; Tracheotomy

Indexed keywords

ADULT; AIRWAY OBSTRUCTION; ANESTHESIST; ARTICLE; ASSISTED VENTILATION; CANNULA; COMPARATIVE STUDY; DEVICES; FEASIBILITY STUDY; GERMANY; HUMAN; MANNEQUIN; MEDICAL SPECIALIST; OPERATION DURATION; OXYGENATION; RESIDENT; SCALPEL; SURGICAL APPROACH; TRACHEOTOMY;

EID: 84862648851     PISSN: 00032417     EISSN: 1432055X     Source Type: Journal    
DOI: 10.1007/s00101-012-2008-2     Document Type: Article
Times cited : (9)

References (20)
  • 2
    • 82455179496 scopus 로고    scopus 로고
    • Emergency anesthesia, airway management and ventilation in major trauma. Background and key messages of the interdisciplinary S3 guidelines for major trauma patients
    • Bernhard M, Matthes G, Kanz KG et al (2011) Emergency anesthesia, airway management and ventilation in major trauma. Background and key messages of the interdisciplinary S3 guidelines for major trauma patients. Anaesthesist 60:1027-1040
    • (2011) Anaesthesist , vol.60 , pp. 1027-1040
    • Bernhard, M.1    Matthes, G.2    Kanz, K.G.3
  • 3
    • 4344563160 scopus 로고    scopus 로고
    • Cricothyroidotomy: A clinical anatomy review
    • DOI 10.1002/ca.10231
    • Boon JM, Abrahams PH, Meiring JH et al (2004) Cricothyroidotomy: a clinical anatomy review. Clin Anat 17:478-486 (Pubitemid 39121697)
    • (2004) Clinical Anatomy , vol.17 , Issue.6 , pp. 478-486
    • Boon, J.M.1    Abrahams, P.H.2    Meiring, J.H.3    Welch, T.4
  • 5
    • 2942521652 scopus 로고    scopus 로고
    • Ventilation of a model lung using various cricothyrotomy devices
    • DOI 10.1111/j.1365-2044.2004.03735.x
    • Craven RM, Vanner RG (2004) Ventilation of a model lung using various cricothyrotomy devices. Anaesthesia 59:595-599 (Pubitemid 38744896)
    • (2004) Anaesthesia , vol.59 , Issue.6 , pp. 595-599
    • Craven, R.M.1    Vanner, R.G.2
  • 6
    • 0025601432 scopus 로고
    • The effective tracheal diameter that causes air trapping during jet ventilation
    • Dworkin R, Benumof JL, Benumof R et al (1990) The effective tracheal diameter that causes air trapping during jet ventilation. J Cardiothorac Anesth 4:731-736
    • (1990) J. Cardiothorac. Anesth. , vol.4 , pp. 731-736
    • Dworkin, R.1    Benumof, J.L.2    Benumof, R.3
  • 7
    • 11244278694 scopus 로고    scopus 로고
    • Deficiencies in the practical management of certain emergency situations. Improvement in the emergency medical qualifications through practice oriented course concepts
    • Gries A, Wilhelm W (2004) Deficiencies in the practical management of certain emergency situations. Improvement in the emergency medical qualifications through practice oriented course concepts. Anaesthesist 53:1043-1044
    • (2004) Anaesthesist , vol.53 , pp. 1043-1044
    • Gries, A.1    Wilhelm, W.2
  • 8
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • DOI 10.1111/j.1365-2044.2004.03831.x
    • Henderson JJ, Popat MT, Latto IP et al (2004) Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 59:675-694 (Pubitemid 38997010)
    • (2004) Anaesthesia , vol.59 , Issue.7 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 9
    • 0022967534 scopus 로고
    • NOTFALLBEATMUNG UBER AMBU-BEUTEL MIT EINEM NEUEN KONIOTOMIE-SET
    • Langenstein H (1986) Emergency ventilation using an Ambu-bag with a new coniotomy set. Anaesthesist 35:697-699 (Pubitemid 17115678)
    • (1986) Anaesthesist , vol.35 , Issue.11 , pp. 697-699
    • Langenstein, H.1
  • 11
    • 80052755694 scopus 로고    scopus 로고
    • A randomized trial comparing two cuffed emergency cricothyrotomy devices using a wire-guided and a catheter-over-needle technique
    • Metterlein T, Frommer M, Ginzkey C et al (2010) A randomized trial comparing two cuffed emergency cricothyrotomy devices using a wire-guided and a catheter-over-needle technique. J Emerg Med 41:326-332
    • (2010) J. Emerg. Med. , vol.41 , pp. 326-332
    • Metterlein, T.1    Frommer, M.2    Ginzkey, C.3
  • 12
    • 80054034746 scopus 로고    scopus 로고
    • The efficacy of spontaneous and controlled ventilation with various cricothyrotomy devices: A quantitative in vitro assessment in a model lung
    • Michalek-Sauberer A, Granegger M, Gilly H (2011) The efficacy of spontaneous and controlled ventilation with various cricothyrotomy devices: a quantitative in vitro assessment in a model lung. J Trauma 71:886-892
    • (2011) J. Trauma. , vol.71 , pp. 886-892
    • Michalek-Sauberer, A.1    Granegger, M.2    Gilly, H.3
  • 14
    • 15044346877 scopus 로고    scopus 로고
    • Invasive techniken in der notfallmedizin: IV. Koniotomie im notarztdienst
    • DOI 10.1007/s00101-004-0768-z
    • Mutzbauer TS, Keul W, Bernhard M et al (2005) Invasive techniques in emergency medicine. IV. Cricothyrotomy in emergency situations. Anaesthesist 54:145-154 (Pubitemid 40379361)
    • (2005) Anaesthesist , vol.54 , Issue.2 , pp. 145-154
    • Mutzbauer, T.S.1    Keul, W.2    Bernhard, M.3    Volkl, A.4    Gries, A.5
  • 15
    • 0020581423 scopus 로고
    • Percutaneous transtracheal ventilation: Experimental and practical aspects
    • Neff CC, Pfister RC, Van Sonnenberg e (1983) Percutaneous transtracheal ventilation: experimental and practical aspects. J Trauma 23:84-90 (Pubitemid 13115094)
    • (1983) Journal of Trauma , vol.23 , Issue.2 , pp. 84-90
    • Neff, C.C.1    Pfister, R.C.2    Van Sonnenberg, E.3
  • 16
    • 77950826428 scopus 로고    scopus 로고
    • Airflow efficacy of ballpoint pen tubes: A consideration for use in bystander cricothyrotomy
    • Owens D, Greenwood B, Galley A et al (2010) Airflow efficacy of ballpoint pen tubes: a consideration for use in bystander cricothyrotomy. Emerg Med J 27:317-320
    • (2010) Emerg. Med. J. , vol.27 , pp. 317-320
    • Owens, D.1    Greenwood, B.2    Galley, A.3
  • 17
    • 84857864883 scopus 로고    scopus 로고
    • Implementation of the laryngeal tube for prehospital airway management: Training of 1, 069 emergency physicians and paramedics
    • Schalk R, Auhuber T, Haller O et al (2012) Implementation of the laryngeal tube for prehospital airway management: training of 1, 069 emergency physicians and paramedics. Anaesthesist 61:35-40
    • (2012) Anaesthesist , vol.61 , pp. 35-40
    • Schalk, R.1    Auhuber, T.2    Haller, O.3
  • 19
    • 33845404662 scopus 로고    scopus 로고
    • Effective ventilation following emergency needle cricothyroidotomy
    • DOI 10.1016/j.resuscitation.2006.08.015, PII S030095720600548X
    • Thompson C, Halder S, Wimbush S (2007) Effective ventilation following emergency needle cricothyroidotomy. Resuscitation 72:164-166 (Pubitemid 44908774)
    • (2007) Resuscitation , vol.72 , Issue.1 , pp. 164-166
    • Thompson, C.1    Halder, S.2    Wimbush, S.3
  • 20
    • 0037315717 scopus 로고    scopus 로고
    • What is the minimum training required for successful cricothyroidotomy? A study in mannequins
    • DOI 10.1097/00000542-200302000-00013
    • Wong DT, Prabhu AJ, Coloma M et al (2003) What is the minimum training required for successful cricothyroidotomy? A study in mannequins. Anesthesiology 98:349-353 (Pubitemid 36592801)
    • (2003) Anesthesiology , vol.98 , Issue.2 , pp. 349-353
    • Wong, D.T.1    Prabhu, A.J.2    Coloma, M.3    Imasogie, N.4    Chung, F.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.