메뉴 건너뛰기




Volumn 37, Issue 7, 2012, Pages 510-516

Thermographic mapping of the skin surface of the head in bald-headed male subjects

Author keywords

Bald headed; Dynamic infrared thermography; Skin circulation; Thermal mapping

Indexed keywords

ANATOMICAL CONCEPTS; ARTICLE; CAMERA; CHEEK; EXTERNAL EAR; EYE; FOREHEAD; HEAD; HUMAN; HUMAN EXPERIMENT; HUMAN TISSUE; IMAGE ANALYSIS; INFRARED PHOTOGRAPHY; INFRARED THERMOGRAPHIC CAMERA; MALE; NORMAL HUMAN; NOSE; OPTICAL RESOLUTION; SKIN BLOOD FLOW; SKIN SURFACE; SKIN TEMPERATURE; TEMPERATURE MEASUREMENT; TISSUE DISTRIBUTION;

EID: 84862639032     PISSN: 03064565     EISSN: 18790992     Source Type: Journal    
DOI: 10.1016/j.jtherbio.2012.05.004     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 63149097867 scopus 로고    scopus 로고
    • Analysis of normal human eye with different age groups using infrared images
    • Acharya U.R., Ng E.Y., Yee G.C., Hua T.J., Kagathi M. Analysis of normal human eye with different age groups using infrared images. J. Med. Syst. 2009, 33:207-213.
    • (2009) J. Med. Syst. , vol.33 , pp. 207-213
    • Acharya, U.R.1    Ng, E.Y.2    Yee, G.C.3    Hua, T.J.4    Kagathi, M.5
  • 3
    • 52049107145 scopus 로고    scopus 로고
    • Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer
    • Arora N., Martins D., Ruggerio D., Tousimis E., Swistel A.J., Osborne M.P., Simmons R.M. Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer. Am. J. Surg. 2008, 196:523-526.
    • (2008) Am. J. Surg. , vol.196 , pp. 523-526
    • Arora, N.1    Martins, D.2    Ruggerio, D.3    Tousimis, E.4    Swistel, A.J.5    Osborne, M.P.6    Simmons, R.M.7
  • 4
    • 69549107714 scopus 로고    scopus 로고
    • The value of dynamic infrared thermography (DIRT) in perforator selection and planning of free DIEP flaps
    • de Weerd L., Weum S., Mercer J.B. The value of dynamic infrared thermography (DIRT) in perforator selection and planning of free DIEP flaps. Ann. Plast. Surg. 2009, 63:274-279.
    • (2009) Ann. Plast. Surg. , vol.63 , pp. 274-279
    • de Weerd, L.1    Weum, S.2    Mercer, J.B.3
  • 6
    • 0035025970 scopus 로고    scopus 로고
    • Deterministic effects in interventional radiology
    • Faulkner K., Vano E. Deterministic effects in interventional radiology. Radiat. Prot. Dosimetry 2001, 94:95-98.
    • (2001) Radiat. Prot. Dosimetry , vol.94 , pp. 95-98
    • Faulkner, K.1    Vano, E.2
  • 7
    • 0010988636 scopus 로고
    • Heat losses from the human head
    • Froese G., Burton A.C. Heat losses from the human head. J. Appl. Physiol. 1957, 10:235-241.
    • (1957) J. Appl. Physiol. , vol.10 , pp. 235-241
    • Froese, G.1    Burton, A.C.2
  • 8
    • 27544460556 scopus 로고    scopus 로고
    • Thermal effects of dorsal head immersion in cold water on nonshivering humans
    • Giesbrecht G.G., Lockhart T.L., Bristow G.K., Steinman A.M. Thermal effects of dorsal head immersion in cold water on nonshivering humans. J. Appl. Physiol. 2005, 99:1958-1964.
    • (2005) J. Appl. Physiol. , vol.99 , pp. 1958-1964
    • Giesbrecht, G.G.1    Lockhart, T.L.2    Bristow, G.K.3    Steinman, A.M.4
  • 10
    • 0029311893 scopus 로고
    • Electronic facial thermography: an analysis of asymptomatic adult subjects
    • Gratt B.M., Sickles E.A. Electronic facial thermography: an analysis of asymptomatic adult subjects. J. Orofacial Pain 1995, 9:255-265.
    • (1995) J. Orofacial Pain , vol.9 , pp. 255-265
    • Gratt, B.M.1    Sickles, E.A.2
  • 11
    • 0006742816 scopus 로고
    • Regional differences in the basal and maximal rates of blood flow in the skin
    • Hertzman A.B., Randall W.C. Regional differences in the basal and maximal rates of blood flow in the skin. J. Appl. Physiol. 1948, 1:234-241.
    • (1948) J. Appl. Physiol. , vol.1 , pp. 234-241
    • Hertzman, A.B.1    Randall, W.C.2
  • 12
    • 0027228047 scopus 로고
    • Gender differences in facial skin blood perfusion during basal and heated conditions determined by laser Doppler flowmetry
    • Mayrovitz H.N., Regan M.B. Gender differences in facial skin blood perfusion during basal and heated conditions determined by laser Doppler flowmetry. Microvasc. Res. 1993, 45:211-218.
    • (1993) Microvasc. Res. , vol.45 , pp. 211-218
    • Mayrovitz, H.N.1    Regan, M.B.2
  • 13
    • 23444446730 scopus 로고    scopus 로고
    • The effect of water-filtered infrared-A (wIRA) irradiation on skin temperature and skin blood flow as evaluated by infrared thermography and scanning laser Doppler imaging
    • Mercer J.B., de Weerd L. The effect of water-filtered infrared-A (wIRA) irradiation on skin temperature and skin blood flow as evaluated by infrared thermography and scanning laser Doppler imaging. Thermol. Int. 2005, 15:89-94.
    • (2005) Thermol. Int. , vol.15 , pp. 89-94
    • Mercer, J.B.1    de Weerd, L.2
  • 14
    • 69249164202 scopus 로고    scopus 로고
    • Fever screening and infrared thermal imaging: concerns and guidelines
    • Mercer J.B., Ring E.F.J. Fever screening and infrared thermal imaging: concerns and guidelines. Thermol. Int. 2009, 19:67-69.
    • (2009) Thermol. Int. , vol.19 , pp. 67-69
    • Mercer, J.B.1    Ring, E.F.J.2
  • 16
    • 12844281027 scopus 로고    scopus 로고
    • Is thermal scanner losing its bite in mass screening of fever due to SARS?
    • Ng E.Y. Is thermal scanner losing its bite in mass screening of fever due to SARS?. Med. Phys. 2005, 32:93-97.
    • (2005) Med. Phys. , vol.32 , pp. 93-97
    • Ng, E.Y.1
  • 17
    • 4143056905 scopus 로고    scopus 로고
    • Analysis of IR thermal imager for mass blind fever screening
    • Ng E.Y., Kaw G.J., Chang W.M. Analysis of IR thermal imager for mass blind fever screening. Microvasc. Res. 2004, 68:104-109.
    • (2004) Microvasc. Res. , vol.68 , pp. 104-109
    • Ng, E.Y.1    Kaw, G.J.2    Chang, W.M.3
  • 20
    • 33746681886 scopus 로고    scopus 로고
    • Thermal effects of whole head submersion in cold water on nonshivering humans
    • Pretorius T., Bristow G.K., Steinman A.M., Giesbrecht G.G. Thermal effects of whole head submersion in cold water on nonshivering humans. J. Appl. Physiol. 2006, 101:669-675.
    • (2006) J. Appl. Physiol. , vol.101 , pp. 669-675
    • Pretorius, T.1    Bristow, G.K.2    Steinman, A.M.3    Giesbrecht, G.G.4
  • 21
    • 84864102827 scopus 로고    scopus 로고
    • The historical development of thermometry and thermal imaging in medicine
    • CRC press, Taylor and Francis, New York, (Chapter 20), J.D. Bronzino (Ed.)
    • Ring E.F., Jones B.F. The historical development of thermometry and thermal imaging in medicine. The Biomedical Engineering Handbook, Medical Devices and Systems 2006, 1-5. CRC press, Taylor and Francis, New York, (Chapter 20). 3rd ed. J.D. Bronzino (Ed.).
    • (2006) The Biomedical Engineering Handbook, Medical Devices and Systems , pp. 1-5
    • Ring, E.F.1    Jones, B.F.2
  • 22
    • 0029098976 scopus 로고
    • Thermographic mapping of perforators and skin blood flow in the free transverse rectus abdominis musculocutaneous flap
    • Salmi A.M., Tukiainen E., Asko-Seljavaara S. Thermographic mapping of perforators and skin blood flow in the free transverse rectus abdominis musculocutaneous flap. Ann. Plast. Surg. 1995, 35:159-164.
    • (1995) Ann. Plast. Surg. , vol.35 , pp. 159-164
    • Salmi, A.M.1    Tukiainen, E.2    Asko-Seljavaara, S.3
  • 23
    • 48649085265 scopus 로고    scopus 로고
    • An infrared thermographic and laser Doppler flowmetric investigation of skin perfusion in the forearm and finger tip following a short period of vasculart stasis
    • Stikbakke E., Mercer J.B. An infrared thermographic and laser Doppler flowmetric investigation of skin perfusion in the forearm and finger tip following a short period of vasculart stasis. Thermol. Int. 2008, 18:107-111.
    • (2008) Thermol. Int. , vol.18 , pp. 107-111
    • Stikbakke, E.1    Mercer, J.B.2
  • 24
    • 0023693902 scopus 로고
    • Quantification of thermal asymmetry. Part 1: normal values and reproducibility
    • Uematsu S., Edwin D.H., Jankel W.R., Kozikowski J., Trattner M. Quantification of thermal asymmetry. Part 1: normal values and reproducibility. J. Neurosurg. 1988, 69:552-555.
    • (1988) J. Neurosurg. , vol.69 , pp. 552-555
    • Uematsu, S.1    Edwin, D.H.2    Jankel, W.R.3    Kozikowski, J.4    Trattner, M.5
  • 25
    • 34250486897 scopus 로고
    • The normal thermographic patterns of the human head
    • van Dulken H., van Voss S.F.C.H. The normal thermographic patterns of the human head. Acta Neurochir. 1971, 23:247-258.
    • (1971) Acta Neurochir. , vol.23 , pp. 247-258
    • van Dulken, H.1    van Voss, S.F.C.H.2
  • 26
  • 27
    • 42649104348 scopus 로고    scopus 로고
    • Reproducibility of infrared thermography measurements in healthy individuals
    • Zaproudina N., Varmavuo V., Airaksinen O., Narhi M. Reproducibility of infrared thermography measurements in healthy individuals. Physiol. Meas. 2008, 29:515-524.
    • (2008) Physiol. Meas. , vol.29 , pp. 515-524
    • Zaproudina, N.1    Varmavuo, V.2    Airaksinen, O.3    Narhi, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.