메뉴 건너뛰기




Volumn , Issue , 2011, Pages 2622-2625

Computerized analysis of narrow-field ROP images for the assessment of vessel caliber and tortuosity

Author keywords

[No Author keywords available]

Indexed keywords

AVERAGE WIDTH; CANNY FILTER; CLINICAL DIAGNOSIS; COMPUTERIZED ANALYSIS; COMPUTERIZED SYSTEMS; CORRELATION COEFFICIENT; EDGE EXTRACTION; ESTIMATED PARAMETER; FUNDUS CAMERA; MANUAL ANALYSIS; MORPHOLOGICAL FEATURES; NON-CONTACT; PREMATURE INFANTS; QUANTITATIVE ASSESSMENTS; RETINAL IMAGE; RETINAL VASCULATURE; RETINOPATHY OF PREMATURITY; VASCULAR ANALYSIS; VISUAL LOSS; WEB-BASED TOOLS;

EID: 84862626977     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090723     Document Type: Conference Paper
Times cited : (15)

References (14)
  • 1
    • 50349120188 scopus 로고
    • Retrolental fibroplasia in premature infants
    • W. C. Owens, E. U. Owens, "Retrolental fibroplasia in premature infants", Am J Ophthalmol, vol. 32,pp. 1-18, 1949.
    • (1949) Am J Ophthalmol , vol.32 , pp. 1-18
    • Owens, W.C.1    Owens, E.U.2
  • 2
    • 0034242565 scopus 로고    scopus 로고
    • Prognostic significance of vascular dilation and tortuosity insufficient for plus disease in retinopathy of prematurity
    • D. K. Wallace, J. A. Kylstra, D. A. Chesnutt, "Prognostic significance of vascular dilation and tortuosity insufficient for plus disease in retinopathy of prematurity", J AAPOS, vol. 4,pp. 224-9, 2000.
    • (2000) J AAPOS , vol.4 , pp. 224-229
    • Wallace, D.K.1    Kylstra, J.A.2    Chesnutt, D.A.3
  • 3
    • 0029936897 scopus 로고    scopus 로고
    • Observer sensitivity to retinal vessel diameter and tortuosity in retinopathy of prematurity: A model system
    • S. F. Freedman, J. A. Klystra, M. S. Capowski, T. D. Realini, C. Rich, et al., "Observer sensitivity to retinal vessel diameter and tortuosity in retinopathy of prematurity: a model system", J Pediatr Ophthalmol Strabismus, vol. 33,pp.248-54, 1996.
    • (1996) J Pediatr Ophthalmol Strabismus , vol.33 , pp. 248-254
    • Freedman, S.F.1    Klystra, J.A.2    Capowski, M.S.3    Realini, T.D.4    Rich, C.5
  • 4
    • 0030742346 scopus 로고    scopus 로고
    • Screening examination of premature infants for retinopathy of prematurity. A joint statement of the American Academy of Pediatrics, the American Association for Pediatric Ophthalmology and Strabismus, and the American Academy of Ophthalmology
    • Screening examination of premature infants for retinopathy of prematurity. A joint statement of the American Academy of Pediatrics, the American Association for Pediatric Ophthalmology and Strabismus, and the American Academy of Ophthalmology, Pediatrics, vol. 100(2 Pt I),p. 273, 1997.
    • (1997) Pediatrics , vol.100 , Issue.2 PART I , pp. 273
  • 5
    • 0033752699 scopus 로고    scopus 로고
    • Guidelines for screening examination for retinopathy of prematurity
    • Canadian Association of Pediatric Ophthalmologists Ad Hoc Committee on Standards of Screening Examination for Retinopathy of Prematurity
    • Canadian Association of Pediatric Ophthalmologists Ad Hoc Committee on Standards of Screening Examination for Retinopathy of Prematurity, "Guidelines for screening examination for retinopathy of prematurity", Can J Ophthalmol, vol. 35,pp 251-2, 2000.
    • (2000) Can J Ophthalmol , vol.35 , pp. 251-252
  • 6
    • 0029822454 scopus 로고    scopus 로고
    • Retinopathy of prematurity: Guidelines for screening and treatment, the report of a joint working party of the Royal College of Ophthalmologists and the British Association of Perinatal Medicine
    • Retinopathy of prematurity: guidelines for screening and treatment, The report of a joint working party of the Royal College of Ophthalmologists and the British Association of Perinatal Medicine, Early Human Dev, vol. 46,pp. 239-58, 1996.
    • (1996) Early Human Dev , vol.46 , pp. 239-258
  • 8
    • 49049106991 scopus 로고    scopus 로고
    • Computerized analysis of retinal vessel width and tortuosity in premature infants
    • C. M. Wilson, K. D: Cocker, M. J. Moseley, C. Paterson, S. T. Clay, et al., "Computerized analysis of retinal vessel width and tortuosity in premature infants", Invest Ophthalmol Vis Sci, vol. 49(8),pp. 3577-85, 2008.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , Issue.8 , pp. 3577-3585
    • Wilson, C.M.1    Cocker, K.D.2    Moseley, M.J.3    Paterson, C.4    Clay, S.T.5
  • 9
    • 48649109117 scopus 로고    scopus 로고
    • Computer-assisted quantification of vascular tortuosity in retinopathy of prematurity (an American Ophthalmological Society Thesis)
    • D. K. Wallace, "Computer-Assisted Quantification of Vascular Tortuosity in Retinopathy of Prematurity (an American Ophthalmological Society Thesis)", Trans Am Ophthalmol Soc, vol. 105,pp. 594-615, 2007.
    • (2007) Trans Am Ophthalmol Soc , vol.105 , pp. 594-615
    • Wallace, D.K.1
  • 10
    • 33947410889 scopus 로고    scopus 로고
    • Semiautomated analysis of retinal vessel diameter in retinopathy of prematurity patients with and without plus disease
    • K. S. Johnson, M. D. Mills, K. A. Karp, J. E. Grunwald, "Semiautomated analysis of retinal vessel diameter in retinopathy of prematurity patients with and without plus disease", Am J Ophthalmol, vol. 143(4),pp. 723-725, 2007.
    • (2007) Am J Ophthalmol , vol.143 , Issue.4 , pp. 723-725
    • Johnson, K.S.1    Mills, M.D.2    Karp, K.A.3    Grunwald, J.E.4
  • 11
    • 70349971828 scopus 로고    scopus 로고
    • Semiautomated digital image analysis of posterior pole vessels in retinopathy of prematurity
    • D. N. Shah, C. M. Wilson, G. S. Ying, K. A. Karp, A. R. Fielder, et al.," Semiautomated digital image analysis of posterior pole vessels in retinopathy of prematurity", J AAPOS, vol. 13,pp. 504-6, 2009.
    • (2009) J AAPOS , vol.13 , pp. 504-506
    • Shah, D.N.1    Wilson, C.M.2    Ying, G.S.3    Karp, K.A.4    Fielder, A.R.5
  • 12
    • 0032319446 scopus 로고    scopus 로고
    • Bilateral filtering for gray and color images
    • C. Tomasi and R. Manduchi, "Bilateral Filtering for Gray and Color Images", Proc Sixth ICCV, pp. 839-846, 1998.
    • (1998) Proc Sixth ICCV , pp. 839-846
    • Tomasi, C.1    Manduchi, R.2
  • 13
    • 0022808786 scopus 로고
    • A computational approach to edge detection
    • J. Canny, "A Computational Approach To Edge Detection", IEEE Trans Pattern Anal Mach Intell, vol. 8(6),pp. 679-698, 1986.
    • (1986) IEEE Trans Pattern Anal Mach Intell , vol.8 , Issue.6 , pp. 679-698
    • Canny, J.1
  • 14
    • 40149101294 scopus 로고    scopus 로고
    • A novel method for the automatic grading of retinal vessel tortuosity
    • E. Grisan, M. Foracchia, A. Ruggeri, "A novel method for the automatic grading of retinal vessel tortuosity", IEEE Trans Med Imaging, vol. 27(3),pp. 310-319, 2008.
    • (2008) IEEE Trans Med Imaging , vol.27 , Issue.3 , pp. 310-319
    • Grisan, E.1    Foracchia, M.2    Ruggeri, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.