메뉴 건너뛰기




Volumn 59, Issue 3 PART 1, 2012, Pages 561-567

Calibration of dual-ended readout of axially oriented 100-mm-long LYSO crystals for use in a compact PET system

Author keywords

100 mm long lutetium yttrium oxyorthosilicate (LYSO); axial positioning calibration; dual ended readout; positron emission tomography (PET); scintillation detectors; unbalanced detectors

Indexed keywords

BALANCED DETECTOR; CALIBRATION CURVES; CALIBRATION METHOD; COLLIMATED BEAMS; COLLIMATED IRRADIATION; DETECTOR RESPONSE; DUAL-ENDED READOUT; IRRADIATION POSITION; LIGHT-SHARING; LINE SOURCES; LONG AXIS; LUTETIUM YTTRIUM OXYORTHOSILICATE; LYSO CRYSTALS; PHOTON INTERACTIONS; POINT SOURCES; POSITION SENSITIVE PHOTOMULTIPLIER TUBE; RAPID METHOD; REFERENCE CURVES; SCINTILLATOR CRYSTALS; SINGLE-EVENT RATES; SMALL-ANIMAL; TRIGGER THRESHOLD; VOLTAGE VARIATION;

EID: 84862606382     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2012.2191978     Document Type: Article
Times cited : (5)

References (13)
  • 4
    • 60449102033 scopus 로고    scopus 로고
    • Design of a high performances small animal PET system with axial oriented crystals and DOI capability
    • Feb
    • S. Salvador, D. Huss, and D. Brasse, "Design of a high performances small animal PET system with axial oriented crystals and DOI capability," IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 17-23, Feb. 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.1 , pp. 17-23
    • Salvador, S.1    Huss, D.2    Brasse, D.3
  • 5
    • 33645990583 scopus 로고    scopus 로고
    • Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes
    • Y. Yang, P. A. Dokhale, R. W. Silverman, K. S. Shah, M. A. McClish, R. Farrell, G. Entine, and S. R. Cherry, "Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes," Phys.Med. Biol., vol. 51, pp. 2131-2142, 2006.
    • (2006) Phys.Med. Biol. , vol.51 , pp. 2131-2142
    • Yang, Y.1    Dokhale, P.A.2    Silverman, R.W.3    Shah, K.S.4    McClish, M.A.5    Farrell, R.6    Entine, G.7    Cherry, S.R.8
  • 8
    • 4444375392 scopus 로고    scopus 로고
    • Evaluation of a prototype small-animal PET detector with depth-of-interaction encoding
    • Aug
    • K. C. Burr and A. Ivan, "Evaluation of a prototype small-animal PET detector with depth-of-interaction encoding," IEEE Trans. Nucl. Sci., vol. 51, no. 4, pp. 1791-1798, Aug. 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.4 , pp. 1791-1798
    • Burr, K.C.1    Ivan, A.2
  • 9
    • 0028494319 scopus 로고
    • Design studies for a PET detector module using a PIN photodiode to measure depth of interaction
    • Aug
    • W. W. Moses and S. E. Derenzo, "Design studies for a PET detector module using a PIN photodiode to measure depth of interaction," IEEE Trans. Nucl. Sci., vol. 41, no. 4, pp. 1441-1445, Aug. 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4 , pp. 1441-1445
    • Moses, W.W.1    Derenzo, S.E.2
  • 10
    • 84856955995 scopus 로고    scopus 로고
    • Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout
    • C. Bircher and Y. Shao, "Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout," Med. Phys., vol. 39, no. 2, pp. 777-787, 2012.
    • (2012) Med. Phys. , vol.39 , Issue.2 , pp. 777-787
    • Bircher, C.1    Shao, Y.2
  • 11
    • 80052937131 scopus 로고    scopus 로고
    • Observations on dual-ended readout of 100 mm long LYSO crystals
    • F. ur-Rehman, B. McIntosh, and A. L. Goertzen, "Observations on dual-ended readout of 100 mm long LYSO crystals," Nucl. Instrum. Methods A, vol. 652, pp. 275-279, 2011.
    • (2011) Nucl. Instrum. Methods A , vol.652 , pp. 275-279
    • Ur-Rehman, F.1    McIntosh, B.2    Goertzen, A.L.3
  • 12
    • 56749169539 scopus 로고    scopus 로고
    • A novelmethod to calibrate DOI function of a PET detector with a dual-ended-scintillator readout
    • Dec
    • Y. Shao, R. Yao, and T. Ma, "A novelmethod to calibrate DOI function of a PET detector with a dual-ended-scintillator readout," Med. Phys., vol. 35, no. 12, pp. 5829-5840, Dec. 2008.
    • (2008) Med. Phys. , vol.35 , Issue.12 , pp. 5829-5840
    • Shao, Y.1    Yao, R.2    Ma, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.