메뉴 건너뛰기




Volumn 24, Issue 3, 2012, Pages 185-190

The usefulness of intraoperative neurophysiological monitoring in cervical spine surgery: A retrospective analysis of 200 consecutive patients

Author keywords

cervical spine surgery; intraoperative neurophysiological monitoring (IONM); somatosensory evoked potential (SSEP); total intravenous anesthesia (TIVA); transcranial electrical motor evoked potentials (TcMEP)

Indexed keywords

FENTANYL; PROPOFOL; SUXAMETHONIUM;

EID: 84862522725     PISSN: 08984921     EISSN: 15371921     Source Type: Journal    
DOI: 10.1097/ANA.0b013e318255ec8f     Document Type: Review
Times cited : (53)

References (29)
  • 1
    • 57749169699 scopus 로고    scopus 로고
    • Adverse events associated with anterior cervical spine surgery [review]
    • Daniels AH, Riew KD, Yoo JU, et al. Adverse events associated with anterior cervical spine surgery [review]. J Am Acad Orthop Surg. 2008;16:729-738.
    • (2008) J. Am. Acad. Orthop. Surg. , vol.16 , pp. 729-738
    • Daniels, A.H.1    Riew, K.D.2    Yoo, J.U.3
  • 2
    • 0021459231 scopus 로고
    • Neurological complications of anterior cervical discectomy in Louisiana
    • Flynn TB. Neurological complications of anterior cervical discectomy in Louisiana. J La State Med Soc. 1984;136:6-8.
    • (1984) J. La. State Med. Soc. , vol.136 , pp. 6-8
    • Flynn, T.B.1
  • 3
    • 40949145601 scopus 로고    scopus 로고
    • Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: A prospective analysis of 1055 consecutive patients
    • Kelleher MO, Tan G, Sarjeant R, et al. Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: A prospective analysis of 1055 consecutive patients. J Neurosurg Spine. 2008;8:215-221.
    • (2008) J. Neurosurg Spine. , vol.8 , pp. 215-221
    • Kelleher, M.O.1    Tan, G.2    Sarjeant, R.3
  • 4
    • 0031434250 scopus 로고    scopus 로고
    • Trends and complications in cervical spine surgery 1989-1993
    • Zeidman SM, Ducker TB, Raycroft J. Trends and complications in cervical spine surgery: 1989-1993. J Spinal Disord. 1997;10:523-526.
    • (1997) J. Spinal Disord. , Issue.10 , pp. 523-526
    • Zeidman, S.M.1    Ducker, T.B.2    Raycroft, J.3
  • 5
    • 0021164879 scopus 로고
    • Spinal cord monitoring as a clinical utilization of the spinal evoked potential
    • Tamaki T, Noguchi T, Takano H, et al. Spinal cord monitoring as a clinical utilization of the spinal evoked potential. Clin Orthop. 1984;84:58-64.
    • (1984) Clin. Orthop. , vol.84 , pp. 58-64
    • Tamaki, T.1    Noguchi, T.2    Takano, H.3
  • 6
    • 1542379004 scopus 로고    scopus 로고
    • Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion
    • Bose B, Sestokas AK, Schwartz DM. Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Spine J. 2004;4:202-207.
    • (2004) Spine J. , vol.4 , pp. 202-207
    • Bose, B.1    Sestokas, A.K.2    Schwartz, D.M.3
  • 7
    • 37349000556 scopus 로고    scopus 로고
    • Risk factors for false positive transcranial motor evoked potential monitoring alerts during surgical treatment of cervical myelopathy
    • Kim DH, Zaremski J, Kwon B, et al. Risk factors for false positive transcranial motor evoked potential monitoring alerts during surgical treatment of cervical myelopathy. Spine. 2007;32:3041-3049.
    • (2007) Spine. , vol.32 , pp. 3041-3049
    • Kim, D.H.1    Zaremski, J.2    Kwon, B.3
  • 8
    • 33748028826 scopus 로고    scopus 로고
    • Characterization of neurophysiologic alerts during anterior cervical spine surgery
    • Lee JY, Hilibrand AS, Lim MR, et al. Characterization of neurophysiologic alerts during anterior cervical spine surgery. Spine. 2006;31:1916-1922.
    • (2006) Spine , vol.31 , pp. 1916-1922
    • Lee, J.Y.1    Hilibrand, A.S.2    Lim, M.R.3
  • 9
    • 2642528878 scopus 로고    scopus 로고
    • Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery
    • 86-A
    • Hilibrand AS, Schwartz DM, Sethuraman V, et al. Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am. 2004;86-A:1248-1253.
    • (2004) J. Bone Joint Surg. Am. , pp. 1248-1253
    • Hilibrand, A.S.1    Schwartz, D.M.2    Sethuraman, V.3
  • 10
    • 40949145601 scopus 로고    scopus 로고
    • Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: A prospective analysis of 1055 consecutive patients
    • Kelleher MO, Tan G, Sarjeant R, et al. Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: A prospective analysis of 1055 consecutive patients. J Neurosurg Spine. 2008;8:215-221.
    • (2008) J. Neurosurg Spine. , vol.8 , pp. 215-221
    • Kelleher, M.O.1    Tan, G.2    Sarjeant, R.3
  • 11
    • 33845737401 scopus 로고    scopus 로고
    • Postoperative segmental C5 palsy after cervical laminoplasty may occur without intraoperative nerve injury: A prospective study with transcranial electric motor-evoke potentials
    • Tanaka N, Nakanishi K, Fujiwara Y, et al. Postoperative segmental C5 palsy after cervical laminoplasty may occur without intraoperative nerve injury: A prospective study with transcranial electric motor-evoke potentials. Spine. 2006;31:3013-3017.
    • (2006) Spine. , vol.31 , pp. 3013-3017
    • Tanaka, N.1    Nakanishi, K.2    Fujiwara, Y.3
  • 12
    • 24744459020 scopus 로고    scopus 로고
    • Somatosensory evoked potential monitoring during anterior cervical discectomy and fusion
    • Taunt CJ Jr, Sidhu KS, Andrew SA. Somatosensory evoked potential monitoring during anterior cervical discectomy and fusion. Spine. 2005;30:1970-1972.
    • (2005) Spine. , vol.30 , pp. 1970-1972
    • Taunt Jr., C.J.1    Sidhu, K.S.2    Andrew, S.A.3
  • 13
    • 33845807038 scopus 로고    scopus 로고
    • Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients-A review of 1,039 cases
    • Smith PN, Balzer JR, Khan MH, et al. Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients-A review of 1,039 cases. Spine J. 2007;7:83-87.
    • (2007) Spine J. , vol.7 , pp. 83-87
    • Smith, P.N.1    Balzer, J.R.2    Khan, M.H.3
  • 14
    • 67649388663 scopus 로고    scopus 로고
    • Neurophysiologic intraoperative monitoring of scoliosis surgery
    • Mendiratta A, Emerson RG. Neurophysiologic intraoperative monitoring of scoliosis surgery. J Clin Neurophysiol. 2009;26:62-69.
    • (2009) J. Clin. Neurophysiol. , vol.26 , pp. 62-69
    • Mendiratta, A.1    Emerson, R.G.2
  • 15
    • 68249126553 scopus 로고    scopus 로고
    • Electrophysiological monitoring during surgery for cervical degenerative myelopathy and radiculopathy
    • Resnick DK, Anderson PA, Kaiser MG, et al. Electrophysiological monitoring during surgery for cervical degenerative myelopathy and radiculopathy. J Neurosurg Spine. 2009;11:245-252.
    • (2009) J. Neurosurg Spine. , vol.11 , pp. 245-252
    • Resnick, D.K.1    Anderson, P.A.2    Kaiser, M.G.3
  • 16
    • 0027189796 scopus 로고
    • Evaluation of intraoperative somatosensory- evoked potential monitoring during 100 cervical operations
    • Epstein NE, Danto J, Nardi D. Evaluation of intraoperative somatosensory- evoked potential monitoring during 100 cervical operations. Spine. 1993;18:737-747.
    • (1993) Spine. , vol.18 , pp. 737-747
    • Epstein, N.E.1    Danto, J.2    Nardi, D.3
  • 17
    • 33644846143 scopus 로고    scopus 로고
    • Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: Experience with 508 cases
    • Khan MH, Smith PN, Balzer JR, et al. Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: Experience with 508 cases. Spine. 2006;31:E105-E113.
    • (2006) Spine. , vol.31
    • Khan, M.H.1    Smith, P.N.2    Balzer, J.R.3
  • 18
    • 2342433422 scopus 로고    scopus 로고
    • Use of somatosensory evoked potentials to detect peripheral ischemia and potential injury resulting from positioning of the surgical patient: Case reports and discussion
    • Jones SC, Fernau R, Woeltjen BL. Use of somatosensory evoked potentials to detect peripheral ischemia and potential injury resulting from positioning of the surgical patient: Case reports and discussion. Spine J. 2004;4:360-362.
    • (2004) Spine J. , vol.4 , pp. 360-362
    • Jones, S.C.1    Fernau, R.2    Woeltjen, B.L.3
  • 19
    • 33646170947 scopus 로고    scopus 로고
    • The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: A retrospective analysis
    • Kamel IR, Drum ET, Koch SA, et al. The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: A retrospective analysis. Anesth Analg. 2006;102: 1538-1542.
    • (2006) Anesth. Analg. , vol.102 , pp. 1538-1542
    • Kamel, I.R.1    Drum, E.T.2    Koch, S.A.3
  • 20
    • 35649015752 scopus 로고    scopus 로고
    • Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery
    • Chwartz DM, Sestokas AK, Hilibrand AS, et al. Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery. J Clin Monit Comput. 2006;20: 437-444.
    • (2006) J. Clin. Monit Comput. , vol.20 , pp. 437-444
    • Chwartz, D.M.1    Sestokas, A.K.2    Hilibrand, A.S.3
  • 21
    • 78650542397 scopus 로고    scopus 로고
    • Intraoperative electrophysiological monitoring in spine surgery
    • Malhotra NR, Shaffrey CI. Intraoperative electrophysiological monitoring in spine surgery. Spine. 2010;35:2167-2179.
    • (2010) Spine. , vol.35 , pp. 2167-2179
    • Malhotra, N.R.1    Shaffrey, C.I.2
  • 22
    • 77955092272 scopus 로고    scopus 로고
    • Patient characteristics and anesthetic technique are additive but not synergistic predictors of successful motor evoked potential monitoring
    • Deiner SG, Kwatra SG, Lin HM, et al. Patient characteristics and anesthetic technique are additive but not synergistic predictors of successful motor evoked potential monitoring. Anesth Analg. 2010;111:421-425.
    • (2010) Anesth. Analg. , vol.111 , pp. 421-425
    • Deiner, S.G.1    Kwatra, S.G.2    Lin, H.M.3
  • 23
    • 0001470918 scopus 로고    scopus 로고
    • Isourane plus nitrous oxide versus propofol for recording of motor evoked potentials after high frequency repetitive electrical stimulation
    • Pechstein U, Nadstawek J, Zentner J, et al. Isourane plus nitrous oxide versus propofol for recording of motor evoked potentials after high frequency repetitive electrical stimulation. Electroencephalogr Clin Neurophysiol. 1998;108:175-181.
    • (1998) Electroencephalogr Clin. Neurophysiol. , vol.108 , pp. 175-181
    • Pechstein, U.1    Nadstawek, J.2    Zentner, J.3
  • 24
    • 0025892738 scopus 로고
    • Isoflurane-induced attenuation of motor evoked potentials caused by electrical motor cortex stimulation during surgery
    • Calancie B, Klose KJ, Baier S, et al. Isoflurane-induced attenuation of motor evoked potentials caused by electrical motor cortex stimulation during surgery. J Neurosurg. 1991;74:897-904.
    • (1991) J. Neurosurg. , vol.74 , pp. 897-904
    • Calancie, B.1    Klose, K.J.2    Baier, S.3
  • 25
    • 70350074271 scopus 로고    scopus 로고
    • Impact of anaesthesia on transcranial electric motor evoked potential monitoring during spine surgery: A review of the literature
    • Wang AC, Than KD, Etame AB, et al. Impact of anaesthesia on transcranial electric motor evoked potential monitoring during spine surgery: A review of the literature. Neurosurg Focus. 2009;27:E7.
    • (2009) Neurosurg. Focus. , vol.27
    • Wang, A.C.1    Than, K.D.2    Etame, A.B.3
  • 26
    • 0036455072 scopus 로고    scopus 로고
    • Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord
    • Sloan TB, Heyer EJ. Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord. J Clin Neurophysiol. 2002;19: 430-433.
    • (2002) J. Clin. Neurophysiol. , vol.19 , pp. 430-433
    • Sloan, T.B.1    Heyer, E.J.2
  • 27
    • 11344288559 scopus 로고    scopus 로고
    • Intravenous anaesthesia and repetitive transcranial magnetic stimulation monitoring in spinal column surgery
    • Hargreaves SJ, Watt JWH. Intravenous anaesthesia and repetitive transcranial magnetic stimulation monitoring in spinal column surgery. Br J Anaesth. 2005;94:70-73.
    • (2005) Br. J. Anaesth. , vol.94 , pp. 70-73
    • Hargreaves, S.J.1    Watt, J.W.H.2
  • 28
    • 77957790013 scopus 로고    scopus 로고
    • Propofol infusion syndrome
    • Wong JM. Propofol infusion syndrome. Am J Therapeut. 2010;17: 487-491.
    • (2010) Am. J. Therapeut. , vol.17 , pp. 487-491
    • Wong, J.M.1
  • 29
    • 77955092272 scopus 로고    scopus 로고
    • Patient characteristics and anesthetic technique are additive but not synergistic predictors of successful motor evoked potential monitoring
    • Deiner SG, Kwatra SG, Lin HM, et al. Patient characteristics and anesthetic technique are additive but not synergistic predictors of successful motor evoked potential monitoring. Anesth Analg. 2010; 111:421-425.
    • (2010) Anesth. Analg. , vol.111 , pp. 421-425
    • Deiner, S.G.1    Kwatra, S.G.2    Lin, H.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.