Volumn , Issue , 2011, Pages 5080-5083

Interplay between bias field correction, intensity standardization, and noise filtering for T2-weighted MRI

Author keywords

[No Author keywords available]

Indexed keywords

BIAS FIELD; COEFFICIENT OF VARIATION; COMPUTERIZED ANALYSIS; EVALUATION MEASURES; EXPERIMENTAL EVALUATION; HIGH RESOLUTION; IN-VIVO; INTENSITY INHOMOGENEITY; INTENSITY STANDARDIZATION; NOISE FILTERING; PATIENT DATASETS; PROSTATE CANCERS; REGION OF INTEREST; TISSUE BOUNDARY;

EID: 84862283408     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091258     Document Type: Conference Paper
Times cited : (27)

References (14)
  • 1
    • 0031987382 scopus 로고    scopus 로고
    • A non-parametric method for automatic correction of intensity non-uniformity in MRI data
    • J.G. Sled et al, "A Non-parametric Method for Automatic Correction of Intensity Non-uniformity in MRI Data," IEEE Trans Med Imaging, vol. 17, pp. 87-97, 1998.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 87-97
    • Sled, J.G.1
  • 2
    • 0033624997 scopus 로고    scopus 로고
    • New variants of a method of MRI scale standardization
    • L. Nzul et al, "New Variants of a Method of MRI Scale Standardization," IEEE Trans Med Imaging, vol. 19, pp. 143-150, 2000.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 143-150
    • Nzul, L.1
  • 3
    • 0025465145 scopus 로고
    • Scale-space and edge detection using anisotropic diffusion
    • P.Perona et al, "Scale-Space and Edge Detection Using Anisotropic Diffusion," IEEE Trans Pat Mach Intel, vol. 12, pp. 629-639, 1990.
    • (1990) IEEE Trans Pat Mach Intel , vol.12 , pp. 629-639
    • Perona, P.1
  • 4
    • 18844365683 scopus 로고    scopus 로고
    • Interplay between intensity standardization and inhomogeneity correction in MR image processing
    • A. Madabhushi et al, "Interplay between Intensity Standardization and Inhomogeneity Correction in MR Image Processing," IEEE Trans Med Imaging, vol. 24, pp. 561-576, 2005.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 561-576
    • Madabhushi, A.1
  • 5
    • 74649086907 scopus 로고    scopus 로고
    • The role of intensity standardization in medical image registration
    • Ulas Bagci et al, "The role of intensity standardization in medical image registration," Pattern Recogn. Lett., vol. 31, 2010.
    • (2010) Pattern Recogn. Lett. , vol.31
    • Bagci, U.1
  • 6
    • 0027850154 scopus 로고
    • Correction of intensity variations in MR images for computer-aided tissue classification
    • B.M Dawant et al, "Correction of intensity variations in MR images for computer-aided tissue classification," IEEE Trans Med Imag, vol. 12, 1993.
    • (1993) IEEE Trans Med Imag , vol.12
    • Dawant, B.M.1
  • 7
    • 2942517541 scopus 로고    scopus 로고
    • Method for bias field correction of brain T1-weighted magnetic resonance images minimizing segmentation error
    • J.D Gispert et al, "Method for bias field correction of brain T1-weighted magnetic resonance images minimizing segmentation error," Hum Brain Mapp, vol. 22, 2004.
    • (2004) Hum Brain Mapp , vol.22
    • Gispert, J.D.1
  • 8
    • 0041874655 scopus 로고    scopus 로고
    • Interaction between noise suppression and inhomogeneity correction in MRI
    • A. Montillo et al, "Interaction between Noise Suppression and Inhomogeneity Correction in MRI," SPIE Med Imag, vol. 5032, pp. 1025-1036, 2003.
    • (2003) SPIE Med Imag , vol.5032 , pp. 1025-1036
    • Montillo, A.1
  • 9
    • 79955758439 scopus 로고    scopus 로고
    • Empirical evaluation of bias field correction algorithms for computer-aided detection of prostate cancer on T2w MRI
    • S. Viswanath, A. Madabhushi et al, "Empirical Evaluation of Bias Field Correction Algorithms for Computer-Aided Detection of Prostate Cancer on T2w MRI," Proc. of SPIE, vol. 7963, 2011.
    • (2011) Proc. of SPIE , vol.7963
    • Viswanath, S.1    Madabhushi, A.2
  • 10
    • 31744442025 scopus 로고    scopus 로고
    • Intensity non-uniformity correction in MRI: Existing Methods and their validation
    • B. Belaroussi et al, "Intensity non-uniformity correction in MRI: Existing Methods and their validation," Med Image Anal, vol. 10, pp. 234-246, 2006.
    • (2006) Med Image Anal , vol.10 , pp. 234-246
    • Belaroussi, B.1
  • 11
    • 28444460771 scopus 로고    scopus 로고
    • Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
    • C.P Loizou et al, "Comparative Evaluation of Despeckle Filtering in Ultrasound Imaging of the Carotid Artery," IEEE T Ultrason Ferr, vol. 52, pp. 1653-1669, 2005.
    • (2005) IEEE T Ultrason Ferr , vol.52 , pp. 1653-1669
    • Loizou, C.P.1
  • 12
    • 80055057005 scopus 로고    scopus 로고
    • Elastic registration of multimodal prostate MRI and histology via multi-attribute, combined mutual information
    • J. Chappelow, A. Madabhushi et al, "Elastic Registration of Multimodal Prostate MRI and Histology via Multi-Attribute, Combined Mutual Information," Medical Physics, vol. 38, 2011.
    • (2011) Medical Physics , vol.38
    • Chappelow, J.1    Madabhushi, A.2
  • 13
    • 29144516340 scopus 로고    scopus 로고
    • Automated detection of prostatic adenocarcinoma from high resolution ex vivo MRI
    • A. Madabhushi et al, "Automated Detection of Prostatic Adenocarcinoma from High Resolution Ex Vivo MRI," IEEE Trans Med Imaging, vol. 24, no. 12, pp. 1611-1625, 2005.
    • (2005) IEEE Trans Med Imaging , vol.24 , Issue.12 , pp. 1611-1625
    • Madabhushi, A.1
  • 14
    • 24344458137 scopus 로고    scopus 로고
    • Feature selection based on mutual information: Criteria of max-dependcy, max relevance, and min-redundancy
    • H. Peng et al, "Feature selection based on mutual information: criteria of max-dependcy, max relevance, and min-redundancy," IEEE Trans Pat Mach Intel, vol. 27, 2005.
    • (2005) IEEE Trans Pat Mach Intel , vol.27
    • Peng, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.