메뉴 건너뛰기




Volumn 5, Issue 2, 2012, Pages 417-424

Rapid high resolution electroanatomical mapping evaluation of a new system in a canine atrial linear lesion model

Author keywords

Catheter ablation; Electrophysiology mapping; Radiofrequency; Tachyarrhythmias

Indexed keywords

ACCURACY; ANIMAL EXPERIMENT; ARTICLE; BREATHING; CARDIOVASCULAR PROCEDURE; CATHETER; CATHETER ABLATION; CORONARY SINUS; ELECTRODE; ELECTROGRAPHY; EXPERIMENTAL DOG; GEOMETRY; HEART PACING; HEART RIGHT ATRIUM; HIGH RESOLUTION ELECTROANATOMICAL MAPPING; INCISION; NONHUMAN; PRIORITY JOURNAL; RADIOFREQUENCY; SINUS RHYTHM; THORACOTOMY; ANIMAL; ANIMAL MODEL; DOG; ELECTROCARDIOGRAPHY; EVALUATION; HEART ATRIUM; HEART ATRIUM FUNCTION; HEART FUNCTION TEST; HISTOLOGY; INSTRUMENTATION; METHODOLOGY; PHYSIOLOGY; REPRODUCIBILITY; SINUS NODE;

EID: 84862265991     PISSN: 19413149     EISSN: 19413084     Source Type: Journal    
DOI: 10.1161/CIRCEP.111.968602     Document Type: Article
Times cited : (137)

References (11)
  • 2
    • 0031811575 scopus 로고    scopus 로고
    • Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter
    • Nakagawa H, Jackman WM. Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter. Pacing Clin Electrophysiol. 1998;21:1279-1286.
    • (1998) Pacing Clin Electrophysiol. , vol.21 , pp. 1279-1286
    • Nakagawa, H.1    Jackman, W.M.2
  • 5
    • 0037161358 scopus 로고    scopus 로고
    • Characterization of reentrant circuits in left atrial macroreentrant tachycardia: Critical isthmus block can prevent atrial tachycardia recurrence
    • Ouyang F, Ernst S, Vogtmann T, Goya M, Volkmer M, Schaumann A, Bansch D, Antz M, Kuck KH. Characterization of reentrant circuits in left atrial macroreentrant tachycardia: critical isthmus block can prevent atrial tachycardia recurrence. Circulation. 2002;105:1934-1942.
    • (2002) Circulation. , vol.105 , pp. 1934-1942
    • Ouyang, F.1    Ernst, S.2    Vogtmann, T.3    Goya, M.4    Volkmer, M.5    Schaumann, A.6    Bansch, D.7    Antz, M.8    Kuck, K.H.9
  • 6
    • 10744231320 scopus 로고    scopus 로고
    • Three-dimensional right atrial geometry construction and catheter tracking using cutaneous patches
    • Sra J, Hauck J, Krum D, Schweitzer J. Three-dimensional right atrial geometry construction and catheter tracking using cutaneous patches. J Cardiovasc Electrophysiol. 2003;14:897.
    • (2003) J Cardiovasc Electrophysiol. , vol.14 , pp. 897
    • Sra, J.1    Hauck, J.2    Krum, D.3    Schweitzer, J.4
  • 8
    • 0032914714 scopus 로고    scopus 로고
    • Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium
    • Gornick CC, Adler SW, Pederson B, Hauck J, Budd J, Schweitzer J. Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium, Circulation. 1999;99:829-835.
    • (1999) Circulation. , vol.99 , pp. 829-835
    • Gornick, C.C.1    Adler, S.W.2    Pederson, B.3    Hauck, J.4    Budd, J.5    Schweitzer, J.6
  • 9
    • 0032168402 scopus 로고    scopus 로고
    • Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: Comparison of contact and reconstructed electrograms during sinus rhythm
    • Schilling RJ, Peters NS, Davies DW. Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm. Circulation. 1998;98:887-898.
    • (1998) Circulation. , vol.98 , pp. 887-898
    • Schilling, R.J.1    Peters, N.S.2    Davies, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.