메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1985-1988

Fabrication of a prototype magnetic stimulator equipped with eccentric spiral coils

Author keywords

[No Author keywords available]

Indexed keywords

DRIVING CIRCUITS; DRIVING CURRENT; MAXIMUM OUTPUT; NEUROLOGICAL DISEASE; SPIRAL COILS; STIMULATOR CIRCUITS;

EID: 84862255892     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090559     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 33646056368 scopus 로고    scopus 로고
    • Reduction of intractable deafferentation pain by navigation-guided repetitive transcranial magnetic stimulation of the primary motor cortex
    • May
    • A. Hirayama, Y. Saitoh, H. Kishima, T. Shimokawa, S. Oshino, M. Hirata, A. Kato, and T. Yoshimine, "Reduction of intractable deafferentation pain by navigation-guided repetitive transcranial magnetic stimulation of the primary motor cortex," Pain, vol. 122, no. 1-2, pp. 22-27, May 2006.
    • (2006) Pain , vol.122 , Issue.1-2 , pp. 22-27
    • Hirayama, A.1    Saitoh, Y.2    Kishima, H.3    Shimokawa, T.4    Oshino, S.5    Hirata, M.6    Kato, A.7    Yoshimine, T.8
  • 2
    • 34548848538 scopus 로고    scopus 로고
    • Reduction of intractable deafferentation pain due to spinal cord or peripheral lesion by high-frequency repetitive transcranial magnetic stimulation of the primary motor cortex
    • Sep
    • Y. Saitoh, A. Hirayama, H. Kishima, T. Shimokawa, S. Oshino, M. Hirata, N. Tani, A. Kato, and T. Yoshimine, "Reduction of intractable deafferentation pain due to spinal cord or peripheral lesion by high-frequency repetitive transcranial magnetic stimulation of the primary motor cortex," J. Neurosurg., vol. 107, no. 3, pp. 555-559, Sep. 2007.
    • (2007) J. Neurosurg. , vol.107 , Issue.3 , pp. 555-559
    • Saitoh, Y.1    Hirayama, A.2    Kishima, H.3    Shimokawa, T.4    Oshino, S.5    Hirata, M.6    Tani, N.7    Kato, A.8    Yoshimine, T.9
  • 4
    • 43749099706 scopus 로고    scopus 로고
    • A six-pound battery-powered portable transcranial magnetic stimulator
    • Apr
    • C. M. Epstein, "A six-pound battery-powered portable transcranial magnetic stimulator," Brain Stimul, vol. 1, no. 2, pp. 128-130, Apr. 2008.
    • (2008) Brain Stimul , vol.1 , Issue.2 , pp. 128-130
    • Epstein, C.M.1
  • 5
    • 77955154226 scopus 로고    scopus 로고
    • Design and construction of a portable transcranial magnetic stimulation (TMS) apparatus for migraine treatment
    • Mar
    • R. C. De Sauvage, A. Beuter, I. Lagroye and B. Veyret. "Design and construction of a portable transcranial magnetic stimulation (TMS) apparatus for migraine treatment" J.Med. Devices, vol. 4, no.1, pp. 015002-1-015002-6. Mar. 2010.
    • (2010) J.Med. Devices , vol.4 , Issue.1 , pp. 0150021-0150026
    • De Sauvage, R.C.1    Beuter, A.2    Lagroye, I.3    Veyret, B.4
  • 6
    • 0021802893 scopus 로고
    • Non-invasive magnetic stimulation of human motor cortex
    • May
    • A. T. Barker, R. Jalinous, and I. L. Freeston, "Non-invasive magnetic stimulation of human motor cortex," Lancet, vol. 1, no. 8437, pp. 1106-1107, May 1985.
    • (1985) Lancet , vol.1 , Issue.8437 , pp. 1106-1107
    • Barker, A.T.1    Jalinous, R.2    Freeston, I.L.3
  • 7
    • 0000442572 scopus 로고
    • Localized stimulation of neural tissues in the brain by means of a paired configuration of time-varying magnetic fields
    • Nov
    • S. Ueno, T. Tashiro, and K. Harada, "Localized stimulation of neural tissues in the brain by means of a paired configuration of time-varying magnetic fields," J. Appl. Phys., vol. 64, no. 10, pp. 5862-5864, Nov. 1988.
    • (1988) J. Appl. Phys. , vol.64 , Issue.10 , pp. 5862-5864
    • Ueno, S.1    Tashiro, T.2    Harada, K.3
  • 8
    • 0026104881 scopus 로고
    • Magnetic stimulation of the motor cortex: Theoretical considerations
    • Feb
    • F. Grandori and P. Ravazzani, "Magnetic stimulation of the motor cortex: Theoretical considerations," IEEE Trans. Biomed. Eng., vol. 38, no. 2, pp. 180-191, Feb. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.2 , pp. 180-191
    • Grandori, F.1    Ravazzani, P.2
  • 9
    • 0034030304 scopus 로고    scopus 로고
    • Magnetic coil design considerations for functional magnetic stimulation
    • May
    • V. W. Lin, I. N. Hsiao, and V. Dhaka, "Magnetic coil design considerations for functional magnetic stimulation," IEEE Trans. Biomed. Eng., vol. 47, no. 5, pp. 600-610, May 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , Issue.5 , pp. 600-610
    • Lin, V.W.1    Hsiao, I.N.2    Dhaka, V.3
  • 10
    • 0034829134 scopus 로고    scopus 로고
    • A 3-D differential coil design for localized magnetic stimulation
    • Oct
    • K. H. Hsu and D. M. Durand, "A 3-D differential coil design for localized magnetic stimulation," IEEE Trans. Biomed. Eng., vol. 48, no. 10, pp. 1162-1168, Oct. 2001.
    • (2001) IEEE Trans. Biomed. Eng. , vol.48 , Issue.10 , pp. 1162-1168
    • Hsu, K.H.1    Durand, D.M.2
  • 11
    • 15944393220 scopus 로고    scopus 로고
    • Transcranial magnetic stimulation of deep brain regions: Evidence for efficacy of the H-coil
    • Apr
    • A. Zangen, Y. Roth, B. Voller and M. Hallett, "Transcranial magnetic stimulation of deep brain regions: Evidence for efficacy of the H-coil," Clin. Neurophysiol., vol. 116, no. 4, pp. 775-779, Apr. 2005.
    • (2005) Clin. Neurophysiol. , vol.116 , Issue.4 , pp. 775-779
    • Zangen, A.1    Roth, Y.2    Voller, B.3    Hallett, M.4
  • 12
    • 0032077312 scopus 로고    scopus 로고
    • Focusing and targeting of magnetic brain stimulation using multiple coils
    • May
    • J. Ruohonen and R. J. Ilmoniemi, "Focusing and targeting of magnetic brain stimulation using multiple coils," Med. Biol. Eng. Comput., vol. 36, no. 3, pp. 297-301, May 1998.
    • (1998) Med. Biol. Eng. Comput. , vol.36 , Issue.3 , pp. 297-301
    • Ruohonen, J.1    Ilmoniemi, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.