메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1608-1611

Decoding of individuated finger movements using surface EMG and input optimization applying a genetic algorithm

Author keywords

Genetic Algorithm (GA); Myoelectric control; Pattern recognition; Surface electrodes; Upper limb prosthesis

Indexed keywords

CLASSIFICATION ACCURACY; DATA SETS; FINGER MOVEMENTS; GA OPTIMIZATION; HIGH REDUNDANCY; INPUT OPTIMIZATION; K-NEAREST NEIGHBORS; LINEAR DISCRIMINANT ANALYSIS; MYOELECTRIC CONTROL; SURFACE ELECTRODES; SURFACE EMG; TIME DOMAIN; UPPER LIMBS;

EID: 84862248333     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090465     Document Type: Conference Paper
Times cited : (25)

References (15)
  • 1
    • 84855429284 scopus 로고    scopus 로고
    • TouchBionics, information available at http://www.touchbionics.com/.
  • 2
    • 84855429283 scopus 로고    scopus 로고
    • bebionic, information available at http://www.bebionic.com/.
  • 6
    • 84055187245 scopus 로고    scopus 로고
    • Integration of a multi-DOF individually adaptable EMG prosthetic system with tactile feedback
    • A. Arieta, W. Yu, and H. Yokoi, "Integration of a Multi-DOF Individually Adaptable EMG Prosthetic System with Tactile Feedback," System, 2004.
    • (2004) System
    • Arieta, A.1    Yu, W.2    Yokoi, H.3
  • 8
    • 0042889301 scopus 로고    scopus 로고
    • Continuous multifunction myoelectric control using pattern recognition
    • Jan
    • K. Englehart, B. Hudgins, and A. D. Chan, "Continuous multifunction myoelectric control using pattern recognition," Technology and Disability, vol. 15, no. 2/2003, pp. 95-103, Jan 2003.
    • (2003) Technology and Disability , vol.15 , Issue.2-2003 , pp. 95-103
    • Englehart, K.1    Hudgins, B.2    Chan, A.D.3
  • 9
    • 50049093848 scopus 로고    scopus 로고
    • A comparison of the effects of electrode implantation and targeting on pattern classification accuracy for prosthesis control
    • Sep
    • T. Farrell and R. Weir, "A comparison of the effects of electrode implantation and targeting on pattern classification accuracy for prosthesis control," Biomedical Engineering, IEEE Transactions on, vol. 55, no. 9, pp. 2198 -2211, Sep. 2008.
    • (2008) Biomedical Engineering IEEE Transactions on , vol.55 , Issue.9 , pp. 2198-2211
    • Farrell, T.1    Weir, R.2
  • 13
    • 0042664129 scopus 로고    scopus 로고
    • A robust, real-time control scheme for multifunction myoelectric control
    • jul
    • K. Englehart and B. Hudgins, "A robust, real-time control scheme for multifunction myoelectric control," Biomedical Engineering, IEEE Transactions on, vol. 50, no. 7, pp. 848 -854, jul 2003.
    • (2003) Biomedical Engineering IEEE Transactions on , vol.50 , Issue.7 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 14
    • 0037627472 scopus 로고    scopus 로고
    • Control of multifunctional prosthetic hands by processing the electromyographic signal
    • Jan
    • M. Zecca, S. Micera, M. C. Carrozza, and P. Dario, "Control of multifunctional prosthetic hands by processing the electromyographic signal." Critical reviews in biomedical engineering, vol. 30, no. 4-6, pp. 459-85, Jan. 2002.
    • (2002) Critical Reviews in Biomedical Engineering , vol.30 , Issue.4-6 , pp. 459-485
    • Zecca, M.1    Micera, S.2    Carrozza, M.C.3    Dario, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.