메뉴 건너뛰기




Volumn 42, Issue 1, 2012, Pages 661-671

Control strategies for harmonic mitigation and power factor correction using shunt active filter under various source voltage conditions

Author keywords

Control algorithms; Non ideal source voltage; Shunt active filter; Source apparent power reduction; THD; Unity power factor

Indexed keywords

APPARENT POWER; NON-IDEAL SOURCES; SHUNT ACTIVE FILTERS; THD; UNITY POWER FACTOR;

EID: 84862233699     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijepes.2012.04.010     Document Type: Article
Times cited : (73)

References (25)
  • 4
    • 0035503711 scopus 로고    scopus 로고
    • Understanding power system harmonics
    • G.W. Mack, and S. Santoso Understanding power system harmonics IEEE Power Eng Rev 21 11 2001 8 11
    • (2001) IEEE Power Eng Rev , vol.21 , Issue.11 , pp. 8-11
    • MacK, G.W.1    Santoso, S.2
  • 6
    • 0029344968 scopus 로고
    • A new power line conditioner for harmonic compensation in power systems
    • H. Akagi, and H. Fujita A new power line conditioner for harmonic compensation in power systems IEEE Trans Power Delivery 10 3 1995 July 1570 1575
    • (1995) IEEE Trans Power Delivery , vol.10 , Issue.3 , pp. 1570-1575
    • Akagi, H.1    Fujita, H.2
  • 7
    • 0029509384 scopus 로고
    • Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads
    • J. Dixon, J. Garcia, and L. Moran Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads IEEE Trans Ind Electron 42 6 1995 636 641
    • (1995) IEEE Trans Ind Electron , vol.42 , Issue.6 , pp. 636-641
    • Dixon, J.1    Garcia, J.2    Moran, L.3
  • 8
    • 38349014004 scopus 로고    scopus 로고
    • Instantaneous reactive power theory applied to active power filter compensation: Different approaches, assessment, and experimental results
    • R. Herrera, P. Salmeron, and H. Kim Instantaneous reactive power theory applied to active power filter compensation: different approaches, assessment, and experimental results IEEE Trans Ind Electron 55 1 2008 184 196
    • (2008) IEEE Trans Ind Electron , vol.55 , Issue.1 , pp. 184-196
    • Herrera, R.1    Salmeron, P.2    Kim, H.3
  • 9
    • 0035306571 scopus 로고    scopus 로고
    • An optimal and flexible control strategy for active filtering and power factor correction under non-sinusoidal line voltages
    • S. Rafiei, H. Toliyat, R. Ghani, and T. Gopalarathnam An optimal and flexible control strategy for active filtering and power factor correction under non-sinusoidal line voltages IEEE Trans Power Delivery 16 2 2001 297 305
    • (2001) IEEE Trans Power Delivery , vol.16 , Issue.2 , pp. 297-305
    • Rafiei, S.1    Toliyat, H.2    Ghani, R.3    Gopalarathnam, T.4
  • 10
    • 54049123659 scopus 로고    scopus 로고
    • Control strategies for load compensation using instantaneous symmetrical component theory under different supply voltages
    • U. Rao, M. Mishra, and A. Ghosh Control strategies for load compensation using instantaneous symmetrical component theory under different supply voltages IEEE Trans Power Delivery 23 4 2008 2310 2317
    • (2008) IEEE Trans Power Delivery , vol.23 , Issue.4 , pp. 2310-2317
    • Rao, U.1    Mishra, M.2    Ghosh, A.3
  • 11
    • 0036957372 scopus 로고    scopus 로고
    • A novel technique for optimizing the harmonics and reactive power under non-sinusoidal voltage conditions
    • Sevilla, Spain; November 5-8
    • George S, Agarwal V. A novel technique for optimizing the harmonics and reactive power under non-sinusoidal voltage conditions. In: Proceedings of 28th annual conference of IEEE industrial electronic society (IECON'02), 2, Sevilla, Spain; November 5-8 2002; p. 858-63.
    • (2002) Proceedings of 28th Annual Conference of IEEE Industrial Electronic Society (IECON'02) , vol.2 , pp. 858-863
    • George, S.1    Agarwal, V.2
  • 13
    • 60449091305 scopus 로고    scopus 로고
    • Combined system for harmonic suppression and reactive power compensation
    • A. Luo, Z. Shuai, W. Zhu, and Z. Shen Combined system for harmonic suppression and reactive power compensation IEEE Trans Ind Electron 56 2 2009 418 428
    • (2009) IEEE Trans Ind Electron , vol.56 , Issue.2 , pp. 418-428
    • Luo, A.1    Shuai, Z.2    Zhu, W.3    Shen, Z.4
  • 14
    • 0033719063 scopus 로고    scopus 로고
    • An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of non-linear loads
    • A. Chandra, B. Singh, B.N. Singh, and K. Al-Haddad An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of non-linear loads IEEE Trans Power Electron 15 3 2000 495 507
    • (2000) IEEE Trans Power Electron , vol.15 , Issue.3 , pp. 495-507
    • Chandra, A.1    Singh, B.2    Singh, B.N.3    Al-Haddad, K.4
  • 16
    • 27844608484 scopus 로고    scopus 로고
    • A novel DSP based algorithm for optimizing the harmonics and reactive power under non-sinusoidal supply voltage conditions
    • S. George, and V. Agarwal A novel DSP based algorithm for optimizing the harmonics and reactive power under non-sinusoidal supply voltage conditions IEEE Trans Power Delivery 20 4 2005 2526 2534
    • (2005) IEEE Trans Power Delivery , vol.20 , Issue.4 , pp. 2526-2534
    • George, S.1    Agarwal, V.2
  • 17
    • 0034228877 scopus 로고    scopus 로고
    • An instantaneous active and reactive current component method for active filters
    • V. Soares, P. Verdelho, and G. Marques An instantaneous active and reactive current component method for active filters IEEE Trans Power Electron 15 4 2000 660 669
    • (2000) IEEE Trans Power Electron , vol.15 , Issue.4 , pp. 660-669
    • Soares, V.1    Verdelho, P.2    Marques, G.3
  • 18
    • 0033706925 scopus 로고    scopus 로고
    • A new approach to load balancing and power factor correction in power distribution system
    • A. Ghosh, and A. Joshi A new approach to load balancing and power factor correction in power distribution system IEEE Trans Power Delivery 15 1 2000 417 422
    • (2000) IEEE Trans Power Delivery , vol.15 , Issue.1 , pp. 417-422
    • Ghosh, A.1    Joshi, A.2
  • 19
    • 33745623393 scopus 로고    scopus 로고
    • Meeting IEEE-519 current harmonics and power factor constraints with a three-Phase three-wire active power filter under distorted source voltages
    • G. Chang, C. Yeh, and W. Chen Meeting IEEE-519 current harmonics and power factor constraints with a three-Phase three-wire active power filter under distorted source voltages IEEE Trans Power Delivery 21 3 2006 July 1648 1654
    • (2006) IEEE Trans Power Delivery , vol.21 , Issue.3 , pp. 1648-1654
    • Chang, G.1    Yeh, C.2    Chen, W.3
  • 20
    • 0033719063 scopus 로고    scopus 로고
    • An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power factor correction and balancing of non-linear loads
    • A. Chandra, B. Singh, B.N. Singh, and K. Al-Haddad An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power factor correction and balancing of non-linear loads IEEE Trans Power Electron 15 3 2000 May 495 507
    • (2000) IEEE Trans Power Electron , vol.15 , Issue.3 , pp. 495-507
    • Chandra, A.1    Singh, B.2    Singh, B.N.3    Al-Haddad, K.4
  • 21
    • 0346707391 scopus 로고    scopus 로고
    • Control algorithm for customer-generated harmonics and reactive power
    • S. Jain, P. Agarwal, and H. Gupta Control algorithm for customer-generated harmonics and reactive power IEEE Trans Power Delivery 19 1 2004 357 366
    • (2004) IEEE Trans Power Delivery , vol.19 , Issue.1 , pp. 357-366
    • Jain, S.1    Agarwal, P.2    Gupta, H.3
  • 22
    • 42249113813 scopus 로고    scopus 로고
    • Optimal control of selective and total harmonic distortion in current and voltage under nonsinusoidal conditions
    • S. George, and V. Agarwal Optimal control of selective and total harmonic distortion in current and voltage under nonsinusoidal conditions IEEE Trans Power Delivery 23 2 2008 937 944
    • (2008) IEEE Trans Power Delivery , vol.23 , Issue.2 , pp. 937-944
    • George, S.1    Agarwal, V.2
  • 23
    • 0141643212 scopus 로고    scopus 로고
    • A theoretical investigation of original and modified instantaneous power theory applied to four-wire systems
    • M. Depenbrock, V. Staudt, and H. Wrede A theoretical investigation of original and modified instantaneous power theory applied to four-wire systems IEEE Trans Ind Appl 39 4 2003 1160 1168
    • (2003) IEEE Trans Ind Appl , vol.39 , Issue.4 , pp. 1160-1168
    • Depenbrock, M.1    Staudt, V.2    Wrede, H.3
  • 24
    • 0029734360 scopus 로고    scopus 로고
    • IEEE Working Group on Nonsinusoidal Situations: Effect on Meter Performance and Definitions of Power. Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads: a discussion January
    • IEEE Working Group on Nonsinusoidal Situations: Effect on Meter Performance and Definitions of Power. Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads: a discussion. IEEE Trans Power Delivery. 1996 January; 11(1), p. 79-101.
    • (1996) IEEE Trans Power Delivery , vol.11 , Issue.1 , pp. 79-101
  • 25
    • 4344620876 scopus 로고    scopus 로고
    • Summary of IEEE standard 1459: Definitions for the measurement of electrical power quantities under sinusoidal, nonsinusoidal, balanced or unbalanced conditions
    • A. Emanuel Summary of IEEE standard 1459: definitions for the measurement of electrical power quantities under sinusoidal, nonsinusoidal, balanced or unbalanced conditions IEEE Trans Ind Appl 40 3 2004 869 876
    • (2004) IEEE Trans Ind Appl , vol.40 , Issue.3 , pp. 869-876
    • Emanuel, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.