메뉴 건너뛰기




Volumn , Issue , 2011, Pages 552-556

Dynamic programming and fuzzy classification for the automatic segmentation of the carotid in ultrasound images

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC DETECTION; AUTOMATIC SEGMENTATIONS; CLINICAL PRACTICES; COEFFICIENT OF VARIATION; COMMON CAROTID ARTERY; COMPUTATION TIME; EDGE DETECTORS; FUZZY CLASSIFICATION; ULTRASOUND IMAGES;

EID: 84862205546     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 1
    • 0033795871 scopus 로고    scopus 로고
    • Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors
    • October
    • D. Baldassarre, M. Amato, A. Bondioli, C. R. Sirtori, and E. Tremoli, "Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors," Stroke, vol. 31, pp. 2426 - 2430, October 2000.
    • (2000) Stroke , vol.31 , pp. 2426-2430
    • Baldassarre, D.1    Amato, M.2    Bondioli, A.3    Sirtori, C.R.4    Tremoli, E.5
  • 2
    • 0037290211 scopus 로고    scopus 로고
    • Engineering a freehand 3D ultrasound system
    • A. Gee, R. Prager, G. Treece, and L. Berman, "Engineering a freehand 3D ultrasound system," Pattern Recogn. Lett., vol. 24, no. 4-5, pp. 757-777, 2003.
    • (2003) Pattern Recogn. Lett. , vol.24 , Issue.4-5 , pp. 757-777
    • Gee, A.1    Prager, R.2    Treece, G.3    Berman, L.4
  • 3
    • 0000815211 scopus 로고
    • A dynamic programming procedure for automated ultrasonic measurement of the carotid artery
    • T. Gustavsson, Q. Liang, I. Wendelhag, and J. Wikstrand, "A dynamic programming procedure for automated ultrasonic measurement of the carotid artery," Computers in Cardiology, pp. 297-300, 1994.
    • (1994) Computers in Cardiology , pp. 297-300
    • Gustavsson, T.1    Liang, Q.2    Wendelhag, I.3    Wikstrand, J.4
  • 4
    • 0030710511 scopus 로고    scopus 로고
    • A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness
    • I. Wendelhag, Q. Liang, T. Gustavsson, and J. Wikstrand, "A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness," Stroke, vol. 28, pp. 2195-2200, 1997.
    • (1997) Stroke , vol.28 , pp. 2195-2200
    • Wendelhag, I.1    Liang, Q.2    Gustavsson, T.3    Wikstrand, J.4
  • 5
    • 0033624995 scopus 로고    scopus 로고
    • A multiscale dynamic programming procedure for boundary detection in ultrasound artery images
    • Q. Liang, I. Wendelhag, J. Wikstrand, and T. Gustavsson, "A multiscale dynamic programming procedure for boundary detection in ultrasound artery images," IEEE Trans. Med. Imag., vol. 19, no. 2, pp. 127-142, 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.2 , pp. 127-142
    • Liang, Q.1    Wendelhag, I.2    Wikstrand, J.3    Gustavsson, T.4
  • 6
    • 0036139071 scopus 로고    scopus 로고
    • Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images
    • D. Cheng, A. Schmidt-Trucksass, K. Cheng, and H. Burkhardt, "Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images," Computer Methods and Programs in Biomedicine, vol. 67, pp. 27-37, 2002.
    • (2002) Computer Methods and Programs in Biomedicine , vol.67 , pp. 27-37
    • Cheng, D.1    Schmidt-Trucksass, A.2    Cheng, K.3    Burkhardt, H.4
  • 10
    • 0036870577 scopus 로고    scopus 로고
    • Speckle reducing anisotropic diffusion
    • Y. Yu and S. Acton, "Speckle reducing anisotropic diffusion," IEEE Trans. Image Processing, vol. 11, no. 11, pp. 1260-1270, 2002.
    • (2002) IEEE Trans. Image Processing , vol.11 , Issue.11 , pp. 1260-1270
    • Yu, Y.1    Acton, S.2
  • 11
    • 9744258807 scopus 로고    scopus 로고
    • Edge detection in ultrasound imagery using the instantaneous coefficient of variation
    • - "Edge detection in ultrasound imagery using the instantaneous coefficient of variation," IEEE Trans. Image Processing, vol. 13, no. 12, pp. 1640-1655, 2004.
    • (2004) IEEE Trans. Image Processing , vol.13 , Issue.12 , pp. 1640-1655
    • Yu, Y.1    Acton, S.2
  • 12
    • 0033289117 scopus 로고    scopus 로고
    • Noninvasive measurement of early atherosclerosis by high-resolution B-mode ultrasonography
    • M. Halenka, "Noninvasive measurement of early atherosclerosis by high-resolution B-mode ultrasonography," Acta-Universitatis Palackianae Olomucensis Facultatis Medicae, vol. 142, pp. 7-12, 1999.
    • (1999) Acta-Universitatis Palackianae Olomucensis Facultatis Medicae , vol.142 , pp. 7-12
    • Halenka, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.