메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 963-966

CMOS monolithic microelectrode array for stimulation and recording of natural neural networks

Author keywords

Band pass filters; CMOS analog integrated circuits; CMOS digital integrated circuits; CMOS technology; Digital recording; Electrodes; Microelectrodes; Neural networks; Platinum; Signal to noise ratio

Indexed keywords

ACTUATORS; ANALOG INTEGRATED CIRCUITS; BANDPASS FILTERS; CMOS INTEGRATED CIRCUITS; DIGITAL INTEGRATED CIRCUITS; ELECTRODES; ELECTROPHYSIOLOGY; INTEGRATED CIRCUITS; MICROELECTRODES; MICROSYSTEMS; NETWORKS (CIRCUITS); NEURAL NETWORKS; PLATINUM; SIGNAL PROCESSING; SOLID-STATE SENSORS; TRANSDUCERS;

EID: 84862101697     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2003.1216927     Document Type: Conference Paper
Times cited : (25)

References (8)
  • 1
    • 0034866512 scopus 로고    scopus 로고
    • Portable Cell-based Biosensor System Using Integrated CMOS Cell-cartridges
    • B. D. deBusschere, et al., "Portable Cell-based Biosensor System Using Integrated CMOS Cell-cartridges", Biosensors & Bioelectronics, Vol. 16, pp. 543-556, 2001.
    • (2001) Biosensors & Bioelectronics , vol.16 , pp. 543-556
    • DeBusschere, B.D.1
  • 2
    • 0037015251 scopus 로고    scopus 로고
    • Silicon Chip for Electronic Communication Between Nerve Cells by Non-invasive Interfacing and Analog-Digital Processing
    • P. Bonifazi, et al., "Silicon Chip for Electronic Communication Between Nerve Cells by Non-invasive Interfacing and Analog-Digital Processing", Advanced Materials, Vol. 14(7), pp. 1190-1193, 2002.
    • (2002) Advanced Materials , vol.14 , Issue.7 , pp. 1190-1193
    • Bonifazi, P.1
  • 3
    • 0034302212 scopus 로고    scopus 로고
    • Drug Evaluations Using Neuronal Networks Cultured on Microelectrode Arrays
    • S. I. Morefield, et al., "Drug Evaluations Using Neuronal Networks Cultured on Microelectrode Arrays", Biosensors and Bioelectronics, Vol. 15, pp. 383-396, 2000.
    • (2000) Biosensors and Bioelectronics , vol.15 , pp. 383-396
    • Morefield, S.I.1
  • 4
    • 0034884441 scopus 로고    scopus 로고
    • Single-Unit Recording with Active Microelectrode Arrays
    • Q. Bai, et al., "Single-Unit Recording with Active Microelectrode Arrays", IEEE Transactions on Biomedical Engineering, Vol. 48(8), pp. 911-920, 2001.
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.8 , pp. 911-920
    • Bai, Q.1
  • 5
    • 0033083227 scopus 로고    scopus 로고
    • The neurochip: A new Multielectrode Device for Stimulating and Recording From Cultured Neurons
    • M. P. Maher, et al., "The neurochip: A new Multielectrode Device for Stimulating and Recording From Cultured Neurons", Journal of Neuroscience Methods, Vol. 87(1), pp. 45-56, 1999.
    • (1999) Journal of Neuroscience Methods , vol.87 , Issue.1 , pp. 45-56
    • Maher, M.P.1
  • 6
    • 84944795772 scopus 로고    scopus 로고
    • Multi Channel Systems GmbH, Reutlingen, Germany
    • Multi Channel Systems GmbH, Reutlingen, Germany.
  • 7
    • 8044223338 scopus 로고
    • Effect of surface topography on the electrode-electrolyte interface impedance. Part I: The high frequency (f > 1 Hz), small-signal interface impedance - A review
    • E. T. McAdams, 'Effect of surface topography on the electrode-electrolyte interface impedance. Part I: The high frequency (f > 1 Hz), small-signal interface impedance - a review", Surface Topography, Vol. 2, pp. 107-122, 1989.
    • (1989) Surface Topography , vol.2 , pp. 107-122
    • McAdams, E.T.1
  • 8
    • 0028400756 scopus 로고
    • Physical Interpretation of Schwan's Limit Voltage of Linearity
    • E. T. Adams, et al., "Physical Interpretation of Schwan's Limit Voltage of Linearity", Medical & Biological Engineering & Computing, Vol. 32, pp. 126-130, 1994.
    • (1994) Medical & Biological Engineering & Computing , vol.32 , pp. 126-130
    • Adams, E.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.