메뉴 건너뛰기




Volumn 11, Issue 3, 2012, Pages 267-271

Rapid measurement of indocyanine green retention by pulse spectrophotometry: A validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma

Author keywords

Child Pugh A; Hepatocellular carcinoma; Indocyanine green clearance; LiMON; Liver cirrhosis; Pulse spectrophotometry

Indexed keywords

INDOCYANINE GREEN;

EID: 84861978536     PISSN: 14993872     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1499-3872(12)60159-3     Document Type: Article
Times cited : (25)

References (25)
  • 1
    • 0031875906 scopus 로고    scopus 로고
    • Problems of hepatectomy in cirrhosis
    • Fan ST. Problems of hepatectomy in cirrhosis. Hepatogastroenterology 1998;45:1288-1290.
    • (1998) Hepatogastroenterology , vol.45 , pp. 1288-1290
    • Fan, S.T.1
  • 4
    • 0033510691 scopus 로고    scopus 로고
    • Hepatectomy for hepatocellular carcinoma: Toward zero hospital deaths
    • Fan ST, Lo CM, Liu CL, Lam CM, Yuen WK, Yeung C, et al. Hepatectomy for hepatocellular carcinoma: toward zero hospital deaths. Ann Surg 1999;229:322-330.
    • (1999) Ann Surg , vol.229 , pp. 322-330
    • Fan, S.T.1    Lo, C.M.2    Liu, C.L.3    Lam, C.M.4    Yuen, W.K.5    Yeung, C.6
  • 5
    • 0036786635 scopus 로고    scopus 로고
    • Improvement in perioperative outcome after hepatic resection: Analysis of 1,803 consecutive cases over the past decade
    • Jarnagin WR, Gonen M, Fong Y, DeMatteo RP, Ben-Porat L, Little S, et al. Improvement in perioperative outcome after hepatic resection: analysis of 1,803 consecutive cases over the past decade. Ann Surg 2002;236:397-407.
    • (2002) Ann Surg , vol.236 , pp. 397-407
    • Jarnagin, W.R.1    Gonen, M.2    Fong, Y.3    Dematteo, R.P.4    Ben-Porat, L.5    Little, S.6
  • 6
    • 0032790193 scopus 로고    scopus 로고
    • Major hepatectomy for hepatocellular carcinoma in patients with an unsatisfactory indocyanine green clearance test
    • Lam CM, Fan ST, Lo CM, Wong J. Major hepatectomy for hepatocellular carcinoma in patients with an unsatisfactory indocyanine green clearance test. Br J Surg 1999;86:1012-1017.
    • (1999) Br J Surg , vol.86 , pp. 1012-1017
    • Lam, C.M.1    Fan, S.T.2    Lo, C.M.3    Wong, J.4
  • 7
    • 79953174883 scopus 로고    scopus 로고
    • Continuous improvement of survival outcomes of resection of hepatocellular carcinoma: A 20-year experience
    • Fan ST, Lo CM, Poon RT, Yeung C, Liu CL, Yuen WK, et al. Continuous improvement of survival outcomes of resection of hepatocellular carcinoma: a 20-year experience. Ann Surg 2011;253:745-758.
    • (2011) Ann Surg , vol.253 , pp. 745-758
    • Fan, S.T.1    Lo, C.M.2    Poon, R.T.3    Yeung, C.4    Liu, C.L.5    Yuen, W.K.6
  • 8
    • 0030880567 scopus 로고    scopus 로고
    • Evaluation of preoperative hepatic function in patients with hepatocellular carcinoma undergoing hepatectomy
    • Lau H, Man K, Fan ST, Yu WC, Lo CM, Wong J. Evaluation of preoperative hepatic function in patients with hepatocellular carcinoma undergoing hepatectomy. Br J Surg 1997;84:1255-1259.
    • (1997) Br J Surg , vol.84 , pp. 1255-1259
    • Lau, H.1    Man, K.2    Fan, S.T.3    Yu, W.C.4    Lo, C.M.5    Wong, J.6
  • 9
    • 4544363070 scopus 로고    scopus 로고
    • Comparison of invasive and noninvasive measurement of plasma disappearance rate of indocyanine green in patients undergoing liver transplantation: A prospective investigator-blinded study
    • Faybik P, Krenn CG, Baker A, Lahner D, Berlakovich G, Steltzer H, et al. Comparison of invasive and noninvasive measurement of plasma disappearance rate of indocyanine green in patients undergoing liver transplantation: a prospective investigator-blinded study. Liver Transpl 2004; 10:1060-1064.
    • (2004) Liver Transpl , vol.10 , pp. 1060-1064
    • Faybik, P.1    Krenn, C.G.2    Baker, A.3    Lahner, D.4    Berlakovich, G.5    Steltzer, H.6
  • 10
    • 70450212834 scopus 로고    scopus 로고
    • Plasma disappearance rate of indocyanine green: A tool to evaluate early graft outcome after liver transplantation
    • Levesque E, Saliba F, Benhamida S, Ichaï P, Azoulay D, Adam R, et al. Plasma disappearance rate of indocyanine green: a tool to evaluate early graft outcome after liver transplantation. Liver Transpl 2009;15:1358-1364.
    • (2009) Liver Transpl , vol.15 , pp. 1358-1364
    • Levesque, E.1    Saliba, F.2    Benhamida, S.3    Ichaï, P.4    Azoulay, D.5    Adam, R.6
  • 11
    • 68049128336 scopus 로고    scopus 로고
    • Perioperative use of the LiMON method of indocyanine green elimination measurement for the prediction and early detection of post-hepatectomy liver failure
    • de Liguori Carino N, O'Reilly DA, Dajani K, Ghaneh P, Poston GJ, Wu AV. Perioperative use of the LiMON method of indocyanine green elimination measurement for the prediction and early detection of post-hepatectomy liver failure. Eur J Surg Oncol 2009;35:957-962.
    • (2009) Eur J Surg Oncol , vol.35 , pp. 957-962
    • de Liguori, C.N.1    O'Reilly, D.A.2    Dajani, K.3    Ghaneh, P.4    Poston, G.J.5    Wu, A.V.6
  • 12
    • 0036433328 scopus 로고    scopus 로고
    • Prognostic value of the indocyanine green plasma disappearance rate in critically ill patients
    • Sakka SG, Reinhart K, Meier-Hellmann A. Prognostic value of the indocyanine green plasma disappearance rate in critically ill patients. Chest 2002;122:1715-1720.
    • (2002) Chest , vol.122 , pp. 1715-1720
    • Sakka, S.G.1    Reinhart, K.2    Meier-Hellmann, A.3
  • 13
    • 0036215279 scopus 로고    scopus 로고
    • Methods and related drawbacks in the estimation of surgical risks in cirrhotic patients undergoing hepatectomy
    • Fan ST. Methods and related drawbacks in the estimation of surgical risks in cirrhotic patients undergoing hepatectomy. Hepatogastroenterology 2002;49:17-20.
    • (2002) Hepatogastroenterology , vol.49 , pp. 17-20
    • Fan, S.T.1
  • 14
    • 79952113528 scopus 로고    scopus 로고
    • Liver functional reserve estimation: State of the art and relevance for local treatments: The Eastern perspective
    • Fan ST. Liver functional reserve estimation: state of the art and relevance for local treatments: the Eastern perspective. J Hepatobiliary Pancreat Sci 2010;17:380-384.
    • (2010) J Hepatobiliary Pancreat Sci , vol.17 , pp. 380-384
    • Fan, S.T.1
  • 15
    • 0842307222 scopus 로고    scopus 로고
    • Evaluation of liver function for hepatic resection for hepatocellular carcinoma in the liver with damaged parenchyma
    • Wakabayashi H, Ishimura K, Izuishi K, Karasawa Y, Maeta H. Evaluation of liver function for hepatic resection for hepatocellular carcinoma in the liver with damaged parenchyma. J Surg Res 2004;116:248-252.
    • (2004) J Surg Res , vol.116 , pp. 248-252
    • Wakabayashi, H.1    Ishimura, K.2    Izuishi, K.3    Karasawa, Y.4    Maeta, H.5
  • 16
    • 44649111962 scopus 로고    scopus 로고
    • Neither multiple tumors nor portal hypertension are surgical contraindications for hepatocellular carcinoma
    • Ishizawa T, Hasegawa K, Aoki T, Takahashi M, Inoue Y, Sano K, et al. Neither multiple tumors nor portal hypertension are surgical contraindications for hepatocellular carcinoma. Gastroenterology 2008;134:1908-1916.
    • (2008) Gastroenterology , vol.134 , pp. 1908-1916
    • Ishizawa, T.1    Hasegawa, K.2    Aoki, T.3    Takahashi, M.4    Inoue, Y.5    Sano, K.6
  • 17
    • 58149512326 scopus 로고    scopus 로고
    • East meets the West--portal pressure predicts outcome of surgical resection for hepatocellular carcinoma
    • Forner A, Bruix J. East meets the West--portal pressure predicts outcome of surgical resection for hepatocellular carcinoma. Nat Clin Pract Gastroenterol Hepatol 2009;6: 14-15.
    • (2009) Nat Clin Pract Gastroenterol Hepatol , vol.6 , pp. 14-15
    • Forner, A.1    Bruix, J.2
  • 18
    • 2342531825 scopus 로고    scopus 로고
    • Preoperative assessment of liver function: A comparison of 99mTc-Mebrofenin scintigraphy with indocyanine green clearance test
    • Erdogan D, Heijnen BH, Bennink RJ, Kok M, Dinant S, Straatsburg IH, et al. Preoperative assessment of liver function: a comparison of 99mTc-Mebrofenin scintigraphy with indocyanine green clearance test. Liver Int 2004;24:117-123.
    • (2004) Liver Int , vol.24 , pp. 117-123
    • Erdogan, D.1    Heijnen, B.H.2    Bennink, R.J.3    Kok, M.4    Dinant, S.5    Straatsburg, I.H.6
  • 19
    • 0028346632 scopus 로고
    • Doppler analysis of hepatic blood flow predicts liver dysfunction after major hepatectomy
    • Kin Y, Nimura Y, Hayakawa N, Kamiya J, Kondo S, Nagino M, et al. Doppler analysis of hepatic blood flow predicts liver dysfunction after major hepatectomy. World J Surg 1994;18: 143-149.
    • (1994) World J Surg , vol.18 , pp. 143-149
    • Kin, Y.1    Nimura, Y.2    Hayakawa, N.3    Kamiya, J.4    Kondo, S.5    Nagino, M.6
  • 20
    • 0036139196 scopus 로고    scopus 로고
    • Pulse oximetry: Its invention, contribution to medicine, and future tasks
    • Aoyagi T, Miyasaka K. Pulse oximetry: its invention, contribution to medicine, and future tasks. Anesth Analg 2002;94:S1-3.
    • (2002) Anesth Analg , vol.94
    • Aoyagi, T.1    Miyasaka, K.2
  • 22
    • 0033784086 scopus 로고    scopus 로고
    • Comparison of invasive and noninvasive measurements of indocyanine green plasma disappearance rate in critically ill patients with mechanical ventilation and stable hemodynamics
    • Sakka SG, Reinhart K, Meier-Hellmann A. Comparison of invasive and noninvasive measurements of indocyanine green plasma disappearance rate in critically ill patients with mechanical ventilation and stable hemodynamics. Intensive Care Med 2000;26:1553-1556.
    • (2000) Intensive Care Med , vol.26 , pp. 1553-1556
    • Sakka, S.G.1    Reinhart, K.2    Meier-Hellmann, A.3
  • 24
    • 0031105463 scopus 로고    scopus 로고
    • Cardiac output and circulating blood volume analysis by pulse dye-densitometry
    • Iijima T, Aoyagi T, Iwao Y, Masuda J, Fuse M, Kobayashi N, et al. Cardiac output and circulating blood volume analysis by pulse dye-densitometry. J Clin Monit 1997;13:81-89.
    • (1997) J Clin Monit , vol.13 , pp. 81-89
    • Iijima, T.1    Aoyagi, T.2    Iwao, Y.3    Masuda, J.4    Fuse, M.5    Kobayashi, N.6
  • 25
    • 0036172926 scopus 로고    scopus 로고
    • Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients
    • Sakka SG, Reinhart K, Wegscheider K, Meier-Hellmann A. Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye dilution and transcutaneous indocyanine green measurement in critically ill patients. Chest 2002;121:559-565.
    • (2002) Chest , vol.121 , pp. 559-565
    • Sakka, S.G.1    Reinhart, K.2    Wegscheider, K.3    Meier-Hellmann, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.