메뉴 건너뛰기




Volumn 20, Issue , 2012, Pages

The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center

Author keywords

Auscultation; Nasogastric tube; pH; Ultrasonography

Indexed keywords

ACID ASPIRATION; ADULT; ARTICLE; AUSCULTATION; COMPARATIVE STUDY; DIGESTIVE TRACT INTUBATION; ECHOGRAPHY; EMERGENCY HEALTH SERVICE; ESOPHAGUS; FEMALE; HUMAN; MALE; MEDICAL ERROR; METHODOLOGY; MIDDLE AGED; PH; PHYSICAL EXAMINATION; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; STOMACH PH; THORAX RADIOGRAPHY; UNCONSCIOUSNESS;

EID: 84861971304     PISSN: None     EISSN: 17577241     Source Type: Journal    
DOI: 10.1186/1757-7241-20-38     Document Type: Article
Times cited : (65)

References (15)
  • 1
    • 0024534005 scopus 로고
    • Pneumothorax due to nasogastric feeding tubes: report of four cases, review of the literature, and recommendations for prevention
    • 10.1001/archinte.1989.00390010156022, 2492185
    • Roubenoff R, Ravich W. Pneumothorax due to nasogastric feeding tubes: report of four cases, review of the literature, and recommendations for prevention. Arch Intern Med 1989, 149:184-188. 10.1001/archinte.1989.00390010156022, 2492185.
    • (1989) Arch Intern Med , vol.149 , pp. 184-188
    • Roubenoff, R.1    Ravich, W.2
  • 2
    • 0030964919 scopus 로고    scopus 로고
    • Radiographic detection of intrabronchial malpositions of nasogastric tubes and subsequent complications in intensive care unit patients
    • 10.1007/s001340050348, 9142579
    • Bankier AA, Wiesmayr MN, Henk C. Radiographic detection of intrabronchial malpositions of nasogastric tubes and subsequent complications in intensive care unit patients. Intensive Care Med 1997, 23:406-410. 10.1007/s001340050348, 9142579.
    • (1997) Intensive Care Med , vol.23 , pp. 406-410
    • Bankier, A.A.1    Wiesmayr, M.N.2    Henk, C.3
  • 3
    • 0037310165 scopus 로고    scopus 로고
    • Sonographic detection of a malpositioned feeding tube causing esophageal perforation in a neonate
    • 10.1002/jcu.10133, 12539253
    • Maruyama K, Shiojima T, Koizumi T. Sonographic detection of a malpositioned feeding tube causing esophageal perforation in a neonate. J Clin Ultrasound 2003, 31:108-110. 10.1002/jcu.10133, 12539253.
    • (2003) J Clin Ultrasound , vol.31 , pp. 108-110
    • Maruyama, K.1    Shiojima, T.2    Koizumi, T.3
  • 5
    • 67349216361 scopus 로고    scopus 로고
    • Colorimetric capnography to ensure correct nasogastric tube position
    • 10.1016/j.jcrc.2008.06.003, 19327299
    • Meyer P, et al. Colorimetric capnography to ensure correct nasogastric tube position. J Crit Care 2009, 24:231-235. 10.1016/j.jcrc.2008.06.003, 19327299.
    • (2009) J Crit Care , vol.24 , pp. 231-235
    • Meyer, P.1
  • 6
    • 79960699323 scopus 로고    scopus 로고
    • Colorimetric capnography, a new procedure to ensure correct feeding tube placement in the intensive care unit: An evaluation of a local protocol
    • 10.1016/j.jcrc.2010.08.007, 20869196
    • Galbois A, et al. Colorimetric capnography, a new procedure to ensure correct feeding tube placement in the intensive care unit: An evaluation of a local protocol. J Crit Care 2011, 26:411-414. 10.1016/j.jcrc.2010.08.007, 20869196.
    • (2011) J Crit Care , vol.26 , pp. 411-414
    • Galbois, A.1
  • 7
    • 0040027137 scopus 로고    scopus 로고
    • Assessing placement of feeding tubes
    • Metheny NA, Titler MG. Assessing placement of feeding tubes. Am J Nurs 2001, 101:36-45.
    • (2001) Am J Nurs , vol.101 , pp. 36-45
    • Metheny, N.A.1    Titler, M.G.2
  • 8
    • 0025077255 scopus 로고
    • Effectiveness of the auscultatory method in predicting feeding tube location
    • Metheny NA, McSweeney M, Wehrle MA, Wiersema L. Effectiveness of the auscultatory method in predicting feeding tube location. Nurs Res 1990, 39(5):262-267.
    • (1990) Nurs Res , vol.39 , Issue.5 , pp. 262-267
    • Metheny, N.A.1    McSweeney, M.2    Wehrle, M.A.3    Wiersema, L.4
  • 9
    • 0029044718 scopus 로고
    • Hold that x-ray: aspirate pH and auscultation prove enteral tube placement
    • 10.1097/00004836-199506000-00007, 7665817
    • Neumann MJ, Meyer CT, Dutton JL, Smith R. Hold that x-ray: aspirate pH and auscultation prove enteral tube placement. J Clin Gastroenterol 1995, 20(4):293-295. 10.1097/00004836-199506000-00007, 7665817.
    • (1995) J Clin Gastroenterol , vol.20 , Issue.4 , pp. 293-295
    • Neumann, M.J.1    Meyer, C.T.2    Dutton, J.L.3    Smith, R.4
  • 10
    • 77955938633 scopus 로고    scopus 로고
    • Effectiveness of the auscultatory and pH methods in predicting feeding tube placement
    • Turgay AS, Khorshid L. Effectiveness of the auscultatory and pH methods in predicting feeding tube placement. J Clin Nurs 2010, 19(11-12):1553-1559.
    • (2010) J Clin Nurs , vol.19 , Issue.11-12 , pp. 1553-1559
    • Turgay, A.S.1    Khorshid, L.2
  • 12
  • 14
    • 84858050258 scopus 로고    scopus 로고
    • WINFOCUS (World Interactive Network Focused On Critical Ultrasound) Group France: Ultrasound to confirm gastric tube placement in prehospital managment
    • 10.1016/j.resuscitation.2011.11.035, 22209831
    • Chenaitia H, Brun PM, Querellou E, Leyral J, Bessereau J, Aimé C, Bouaziz R, Georges A, Louis F. WINFOCUS (World Interactive Network Focused On Critical Ultrasound) Group France: Ultrasound to confirm gastric tube placement in prehospital managment. Resuscitation 2012, 83:447-451. 10.1016/j.resuscitation.2011.11.035, 22209831.
    • (2012) Resuscitation , vol.83 , pp. 447-451
    • Chenaitia, H.1    Brun, P.M.2    Querellou, E.3    Leyral, J.4    Bessereau, J.5    Aimé, C.6    Bouaziz, R.7    Georges, A.8    Louis, F.9
  • 15
    • 27744434520 scopus 로고    scopus 로고
    • Sonography as an alternative to radiography for nasogastric feeding tube location
    • 10.1007/s00134-005-2791-1, 16172849
    • Vigneau C, Baudel JL, Guidet B, Offenstadt G, Maury E. Sonography as an alternative to radiography for nasogastric feeding tube location. Intensive Care Med 2005, 31(11):1570-1572. 10.1007/s00134-005-2791-1, 16172849.
    • (2005) Intensive Care Med , vol.31 , Issue.11 , pp. 1570-1572
    • Vigneau, C.1    Baudel, J.L.2    Guidet, B.3    Offenstadt, G.4    Maury, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.