메뉴 건너뛰기




Volumn , Issue , 2011, Pages 916-919

Evaluation of a resectable ultrasound liver phantom for testing of surgical navigation systems

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER ASSISTED; DATA SETS; LIVER RESECTIONS; SEGMENTATION TECHNIQUES; SURGICAL ASSISTANCE; SURGICAL NAVIGATION SYSTEMS; TUMOR MODELS; VIRTUAL 3D MODEL;

EID: 84861940966     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090205     Document Type: Conference Paper
Times cited : (8)

References (13)
  • 1
    • 0019508569 scopus 로고
    • Evaluating performance characteristics in computerized tomography
    • March
    • D. R. White, R. D. Speller, P. M. Taylor, "Evaluating performance characteristics in computerized tomography", The British Journal of Radiology, March 1981, 54(639), pp. 221-31.
    • (1981) The British Journal of Radiology , vol.54 , Issue.639 , pp. 221-231
    • White, D.R.1    Speller, R.D.2    Taylor, P.M.3
  • 2
    • 0032922893 scopus 로고    scopus 로고
    • An anthropomorphic phantom for receiver operating characteristic studies in CT imaging of liver lesions
    • January
    • H. M. Olerud, J. B. Olsen, A. Skretting, "An anthropomorphic phantom for receiver operating characteristic studies in CT imaging of liver lesions", The British Journal of Radiology, January 1999, 72(853), pp. 35-43.
    • (1999) The British Journal of Radiology , vol.72 , Issue.853 , pp. 35-43
    • Olerud, H.M.1    Olsen, J.B.2    Skretting, A.3
  • 3
    • 44349132160 scopus 로고    scopus 로고
    • Robust surface registration using salient anatomical features for image-guided liver surgery: Algorithm and validation
    • June
    • L. W. Clementsa, W. C. Chapman, B. M. Dawant, R. L. Galloway, Jr. I. Miga and M. I. Miga, "Robust surface registration using salient anatomical features for image-guided liver surgery: Algorithm and validation", Medical Physics, June 2008, 35(6), pp. 2528-2540.
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2528-2540
    • Clementsa, L.W.1    Chapman, W.C.2    Dawant, B.M.3    Galloway, R.L.4    Miga Jr., I.5    Miga, M.I.6
  • 4
    • 0028918295 scopus 로고
    • An easily made, low-cost, tissue-like ultrasound phantom material
    • John Wiley & Sons
    • R. O. Bude, R. S. Adler, "An Easily Made, Low-Cost, Tissue-Like Ultrasound Phantom Material", J. Clin. Ultrasound 23, John Wiley & Sons (1995), pp. 271-273.
    • (1995) J. Clin. Ultrasound , vol.23 , pp. 271-273
    • Bude, R.O.1    Adler, R.S.2
  • 5
    • 0031040246 scopus 로고    scopus 로고
    • Training phantom for ultrasound guided biopsy
    • R. A. Nicholson, M. Crofton, "Training phantom for ultrasound guided biopsy", The British J. of Radiology, 70, 1997, pp. 192-194.
    • (1997) The British J. of Radiology , vol.70 , pp. 192-194
    • Nicholson, R.A.1    Crofton, M.2
  • 7
    • 84855450109 scopus 로고    scopus 로고
    • 91096 Moehrendorf Germany
    • QRM GmbH, Dorfstrasse 4, 91096 Moehrendorf Germany, www.qrm.de.
    • Dorfstrasse , vol.4
  • 8
    • 84855455561 scopus 로고    scopus 로고
    • P. O. Box 186 Elkhart, IN 46515 USA
    • P. O. Box 186 Elkhart, IN 46515 USA, www.supertechx-ray.com.
  • 13
    • 0029023568 scopus 로고
    • Clinical applications of frameless stereotactic devices in neurotology: Preliminary report
    • M. M. Goldsmith, R. D. Bucholz, K. R. Smith, N. Nitsche, "Clinical applications of frameless stereotactic devices in neurotology: preliminary report", American Journal of Otolaryngology 16(4), 1995, pp. 475-479.
    • (1995) American Journal of Otolaryngology , vol.16 , Issue.4 , pp. 475-479
    • Goldsmith, M.M.1    Bucholz, R.D.2    Smith, K.R.3    Nitsche, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.