메뉴 건너뛰기




Volumn , Issue , 2011, Pages 397-400

Development of a fully automated closed loop artificial pancreas control system with dual pump delivery of insulin and glucagon

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATED MEASUREMENT; BLOOD GLUCOSE LEVEL; BLOOD SUGAR LEVELS; BLOOD SUGARS; CLOSED LOOPS; CLOSED-LOOP; DUAL SENSOR; GAIN FACTORS; GLYCEMIC CONTROL; HUMAN INTERACTIONS; INSULIN SENSITIVITY; LONG-TERM EFFECTS; SENSOR ACQUISITION; SOFTWARE APPLICATIONS; SUBCUTANEOUS ROUTE; TWO-PUMP;

EID: 84861935134     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090127     Document Type: Conference Paper
Times cited : (25)

References (20)
  • 1
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • Group Diabetes Control and Complications Research
    • Group, Diabetes Control and Complications Research, "The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus,"New England Journal of Medicine, vol. 329, pp. 977-986, 1993.
    • (1993) New England Journal of Medicine , vol.329 , pp. 977-986
  • 2
    • 77956071742 scopus 로고    scopus 로고
    • Novel use of glucagon in a closed loop system for prevention of hypoglycemia in type 1 diabetes
    • March
    • J.R. Castle, J.M. Engle, J. El Youssef, R.G. Massoud, K.C. Yuen, R. Kagan, W.K. Ward, " Novel use of glucagon in a closed loop system for prevention of hypoglycemia in type 1 diabetes,"Diabetes Care, vol. 33, no. 6, pp. 1282-1287, March 2010.
    • (2010) Diabetes Care , vol.33 , Issue.6 , pp. 1282-1287
    • Castle, J.R.1    Engle, J.M.2    El Youssef, J.3    Massoud, R.G.4    Yuen, K.C.5    Kagan, R.6    Ward, W.K.7
  • 4
    • 84887257430 scopus 로고    scopus 로고
    • Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic Swine
    • F.H. El-Khatib, J. Jiang, E.R. Damiano, "Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic Swine", J. Diabetes Sci. Technol, vol. 1, no. 2, pp. 181-92.
    • J. Diabetes Sci. Technol , vol.1 , Issue.2 , pp. 181-192
    • El-Khatib, F.H.1    Jiang, J.2    Damiano, E.R.3
  • 5
    • 0007424620 scopus 로고
    • Automation control of blood sugar. I. A servomechanism for glucose monitoring and control
    • April
    • A.H. Kadish, "Automation control of blood sugar. I. A servomechanism for glucose monitoring and control", Am. J. Med. Electron, vol. 3, pp. 82-86, April 1964.
    • (1964) Am. J. Med. Electron , vol.3 , pp. 82-86
    • Kadish, A.H.1
  • 7
    • 0016259390 scopus 로고
    • The artificial beta cell - A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system
    • September
    • E.F. Pfeiffer, C. Thum, A.H. Clemens, "The artificial beta cell - a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)," Horm.Metab. Res., vol. 6, no. 5, pp. 339-342, September 1974.
    • (1974) Horm.Metab. Res. , vol.6 , Issue.5 , pp. 339-342
    • Pfeiffer, E.F.1    Thum, C.2    Clemens, A.H.3
  • 8
    • 0017338283 scopus 로고
    • The development of Biostator, a glucose controlled insulin infusion system (GCIIS)
    • A.H. Clemens, P.H. Chang, R.W. Myers, "The development of Biostator, a glucose controlled insulin infusion system (GCIIS)," Horm.Metab. Res., vol. 7, pp. 23-33, 1977.
    • (1977) Horm.Metab. Res. , vol.7 , pp. 23-33
    • Clemens, A.H.1    Chang, P.H.2    Myers, R.W.3
  • 9
    • 0032962321 scopus 로고    scopus 로고
    • A model-based algorithm for blood glucose control in type i diabetic patients
    • R.S. Parker, F.J. Doyle, "A model-based algorithm for blood glucose control in type I diabetic patients," IEEE Transactions in Biomedical Engineering, vol. 46, no. 2, pp. 148-157, 1999.
    • (1999) IEEE Transactions in Biomedical Engineering , vol.46 , Issue.2 , pp. 148-157
    • Parker, R.S.1    Doyle, F.J.2
  • 10
    • 0020957975 scopus 로고
    • PACBERG. an adaptive program for controlling the blood sugar
    • G. Pacini, R.N. Bergman, "PACBERG. an adaptive program for controlling the blood sugar,"Comput. Programs Biomed., vol. 16, no. 1-2, pp. 13-20, 1983.
    • (1983) Comput. Programs Biomed. , vol.16 , Issue.1-2 , pp. 13-20
    • Pacini, G.1    Bergman, R.N.2
  • 14
    • 0035317349 scopus 로고    scopus 로고
    • A neural network approach in diabetes management by insulin administration
    • April
    • G. Gogou, N. Maglaveras, B.V. Ambrosiadou, D. Goulis, C. Pappas, "A neural network approach in diabetes management by insulin administration," J Med Syst., vol. 25, no. 2, pp. 119-131, April 2001.
    • (2001) J Med Syst. , vol.25 , Issue.2 , pp. 119-131
    • Gogou, G.1    Maglaveras, N.2    Ambrosiadou, B.V.3    Goulis, D.4    Pappas, C.5
  • 15
    • 0035105899 scopus 로고    scopus 로고
    • The control of blood glucose in the critical diabetic patient: A neurofuzzy method
    • March
    • D. Dazzi, F. Taddei, A. Gavarini, E. Uggeri, R. Negro, A. Pezzarossa. The control of blood glucose in the critical diabetic patient: a neurofuzzy method," J. Diabetes Complications, vol. 15, no. 2, pp. 80-87, March 2001.
    • (2001) J. Diabetes Complications , vol.15 , Issue.2 , pp. 80-87
    • Dazzi, D.1    Taddei, F.2    Gavarini, A.3    Uggeri, E.4    Negro, R.5    Pezzarossa, A.6
  • 16
    • 0024553413 scopus 로고
    • Intelligent instrumentation in diabetic management
    • A. M. Albisser, "Intelligent instrumentation in diabetic management," Crit. Rev. Biomed. Eng., vol. 17, no. 1, pp. 1-24, 1989.
    • (1989) Crit. Rev. Biomed. Eng. , vol.17 , Issue.1 , pp. 1-24
    • Albisser, A.M.1
  • 17
    • 0017704494 scopus 로고
    • Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreas
    • July
    • E. B. Marliss, F.T. Murray, E.F. Stokes, B. Zinman, A.F. Nakhooda, A. Denoga, B.S. Leibel, A.M. Albisser, "Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreas," Diabetes, vol. 26, no. pp. 663-672, July 1977.
    • (1977) Diabetes , vol.26 , pp. 663-672
    • Marliss, E.B.1    Murray, F.T.2    Stokes, E.F.3    Zinman, B.4    Nakhooda, A.F.5    Denoga, A.6    Leibel, B.S.7    Albisser, A.M.8
  • 18
    • 27744588950 scopus 로고    scopus 로고
    • A novel insulin delivery algorithm in rats with type 1 diabetes: The fading memory proportionalderivative method
    • August
    • B. Gopakumaran, H.M. Duman, D.P. Overholser, I.F. Federiuk, M.J. Quinn, M.D. Wood, W.K. Ward, "A novel insulin delivery algorithm in rats with type 1 diabetes: the fading memory proportionalderivative method," Artificial Organs, vol. 29, no. 8, pp. 599-607, August 2005.
    • (2005) Artificial Organs , vol.29 , Issue.8 , pp. 599-607
    • Gopakumaran, B.1    Duman, H.M.2    Overholser, D.P.3    Federiuk, I.F.4    Quinn, M.J.5    Wood, M.D.6    Ward, W.K.7
  • 19
    • 77950062222 scopus 로고    scopus 로고
    • Amperometric glucose sensors: Sources of error and potential benefit of redundancy
    • January
    • J.R. Castle, W.K. Ward, "Amperometric glucose sensors: sources of error and potential benefit of redundancy",J. Diabetes Sci Technol., vol. 4, pp. 221-225, January 2010.
    • (2010) J. Diabetes Sci Technol. , vol.4 , pp. 221-225
    • Castle, J.R.1    Ward, W.K.2
  • 20
    • 0347624612 scopus 로고    scopus 로고
    • Modeling beta-cell insulin secretion - Implications for closed-loop glucose homeostasis
    • G. M. Steil, R. Janowski, C. Darwin, M.F. Saad, "Modeling beta-cell insulin secretion - implications for closed-loop glucose homeostasis," Diabetes Technol. Ther., vol. 5, no. 6, pp. 953-964, 2003.
    • (2003) Diabetes Technol. Ther. , vol.5 , Issue.6 , pp. 953-964
    • Steil, G.M.1    Janowski, R.2    Darwin, C.3    Saad, M.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.