메뉴 건너뛰기




Volumn 31, Issue 7, 2012, Pages 750-756

Pilot investigation of a novel testing strategy for bleeding in ventricular assist device recipients

Author keywords

axial flow; bleeding complications; heart failure; high molecular weight von Willebrand factor multimers; left ventricular assist device

Indexed keywords

BLOOD CLOTTING FACTOR 8; RISTOCETIN; VON WILLEBRAND FACTOR;

EID: 84861880734     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2012.02.032     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009;361:2241-51.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 2
    • 58249093243 scopus 로고    scopus 로고
    • Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
    • Crow S, John R, Boyle A, et al. Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. J Thorac Cardiovasc Surg 2009;137:208-15.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 208-215
    • Crow, S.1    John, R.2    Boyle, A.3
  • 3
    • 77951264913 scopus 로고    scopus 로고
    • Increased incidence of gastro-intestinal bleeding following implantation of the HeartMate II LVAD
    • Stern DR, Kazam J, Edwards P, et al. Increased incidence of gastro-intestinal bleeding following implantation of the HeartMate II LVAD. J Card Surg 2010;25:352-6.
    • (2010) J Card Surg , vol.25 , pp. 352-356
    • Stern, D.R.1    Kazam, J.2    Edwards, P.3
  • 4
    • 40649123746 scopus 로고    scopus 로고
    • Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
    • Geisen U, Heilmann C, Beyersdorf F, et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 2008; 33:679-84.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 679-684
    • Geisen, U.1    Heilmann, C.2    Beyersdorf, F.3
  • 5
    • 77956393954 scopus 로고    scopus 로고
    • Comparative analysis of von Willebrand factor profiles in pulsatile and continuous left ventricular assist device recipients
    • Crow S, Milano C, Joyce L, et al. Comparative analysis of von Willebrand factor profiles in pulsatile and continuous left ventricular assist device recipients. ASAIO J 2010;56:441-5.
    • (2010) ASAIO J , vol.56 , pp. 441-445
    • Crow, S.1    Milano, C.2    Joyce, L.3
  • 6
    • 77957561535 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation
    • Uriel N, Pak S-W, Jorde UP, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol 2010;56:1207-13.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1207-1213
    • Uriel, N.1    Pak, S.-W.2    Jorde, U.P.3
  • 7
    • 38349116242 scopus 로고    scopus 로고
    • A highly-sensitive plasma von Willebrand factor ristocetin cofactor (VWF:RCo) activity assay by flow cytometry
    • Chen D, Daigh CA, Hendricksen JI, et al. A highly-sensitive plasma von Willebrand factor ristocetin cofactor (VWF:RCo) activity assay by flow cytometry. J Thromb Haemost 2008;6:323-30.
    • (2008) J Thromb Haemost , vol.6 , pp. 323-330
    • Chen, D.1    Daigh, C.A.2    Hendricksen, J.I.3
  • 8
    • 33749134020 scopus 로고    scopus 로고
    • Performance and clinical utility of a commercial von Willebrand factor collagen binding assay for laboratory diagnosis of von Willebrand disease
    • DOI 10.1373/clinchem.2006.070730
    • Popov J, Zhukov O, Ruden S, et al. Performance and clinical utility of a commercial von Willebrand factor collagen binding assay for laboratory diagnosis of von Willebrand disease. Clin Chem 2006;52: 1965-7. (Pubitemid 44470707)
    • (2006) Clinical Chemistry , vol.52 , Issue.10 , pp. 1965-1967
    • Popov, J.1    Zhukov, O.2    Ruden, S.3    Zeschmann, T.4    Sferruzza, A.5    Sahud, M.6
  • 9
    • 80051584241 scopus 로고    scopus 로고
    • Value assignment of the WHO 2nd International Standard von Willebrand factor, concentrate (09/182)
    • Hubbard AR, Hamill M, Beeharry M, Bevan SA, Heath AB. Value assignment of the WHO 2nd International Standard von Willebrand factor, concentrate (09/182). J Thromb Haemost 2011; 9:1638-40.
    • (2011) J Thromb Haemost , vol.9 , pp. 1638-1640
    • Hubbard, A.R.1    Hamill, M.2    Beeharry, M.3    Bevan, S.A.4    Heath, A.B.5
  • 10
    • 34249669219 scopus 로고    scopus 로고
    • A new automated screening assay for the diagnosis of von Willebrand disease
    • Salem RO, Van Cott EM. A new automated screening assay for the diagnosis of von Willebrand disease. Am J Clin Pathol 2007;127: 730-5.
    • (2007) Am J Clin Pathol , vol.127 , pp. 730-735
    • Salem, R.O.1    Van Cott, E.M.2
  • 11
    • 33745373016 scopus 로고    scopus 로고
    • Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease
    • DOI 10.1097/01.mbc.0000233365.10981.08, PII 0000172120060700000004
    • De Vleeschauwer A, Devreese K. Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease. Blood Coagul Fibrinolysis 2006;17:353-8. (Pubitemid 43941577)
    • (2006) Blood Coagulation and Fibrinolysis , vol.17 , Issue.5 , pp. 353-358
    • Vleeschauwer, A.D.1    Devreese, K.2
  • 12
    • 80053417668 scopus 로고    scopus 로고
    • Validation of an automated latex particle-enhanced immunoturbidimetric von Willebrand factor activity assay
    • Chen D, Tange JI, Meyers BJ, et al. Validation of an automated latex particle-enhanced immunoturbidimetric von Willebrand factor activity assay. J Thromb Haemost 2011;9:1993-2002.
    • (2011) J Thromb Haemost , vol.9 , pp. 1993-2002
    • Chen, D.1    Tange, J.I.2    Meyers, B.J.3
  • 13
    • 0022529452 scopus 로고
    • A two-site, monoclonal antibody-based immunoassay for von Willebrand factor. Demonstration that vWF function resides in a conformational epitope
    • Chand S, McCraw A, Hutton R, Tuddenham EG, Goodall AH. A two-site, monoclonal antibody-based immunoassay for von Willebrand factor- demonstration that vWF function resides in a conformational epitope. Thromb Haemost 1986;55:318-24. (Pubitemid 16074155)
    • (1986) Thrombosis and Haemostasis , vol.55 , Issue.3 , pp. 318-324
    • Chand, S.1    McCraw, A.2    Hutton, R.3
  • 14
    • 0030695365 scopus 로고    scopus 로고
    • Von Willebrand factor activity detected in a monoclonal antibody-based ELISA: An alternative to the ristocetin cofactor platelet agglutination assay for diagnostic use
    • Murdock PJ, Woodhams BJ, Matthews KB, Pasi KJ, Goodall AH. von Willebrand factor activity detected in a monoclonal antibody-based ELISA: an alternative to the ristocetin cofactor platelet agglutination assay for diagnostic use. Thromb Haemost 1997;78:1272-7. (Pubitemid 27464598)
    • (1997) Thrombosis and Haemostasis , vol.78 , Issue.4 , pp. 1272-1277
    • Murdock, P.J.1    Woodhams, B.J.2    Matthews, K.B.3    Pasi, K.J.4    Goodall, A.H.5
  • 17
    • 0037636659 scopus 로고    scopus 로고
    • Left ventricular assist devices and bleeding: Adding insult to injury
    • DOI 10.1016/S0003-4975(03)00478-8, PII S0003497503004788
    • Goldstein DJ, Beauford RB. Left ventricular assist devices and bleeding: adding insult to injury. Ann Thorac Surg 2003;75(6 Suppl):S42-47. (Pubitemid 36677189)
    • (2003) Annals of Thoracic Surgery , vol.75 , Issue.6 SUPPL.
    • Goldstein, D.J.1    Beauford, R.B.2
  • 19
    • 77957167053 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients
    • discussion 1269
    • Crow S, Chen D, Milano C, et al. Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients. Ann Thorac Surg 2010;90:1263-9; discussion 1269.
    • (2010) Ann Thorac Surg , vol.90 , pp. 1263-1269
    • Crow, S.1    Chen, D.2    Milano, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.