메뉴 건너뛰기




Volumn 3, Issue 2, 2012, Pages 684-691

Co-optimal placement of measurement devices and their related communication infrastructure in wide area measurement systems

Author keywords

Communication link placement; meter placement; power system communication infrastructure; state estimation; wide area measurement system

Indexed keywords

COMMUNICATION INFRASTRUCTURE; CONVENTIONAL MEASUREMENTS; DATA TRANSMITTING; ENERGY MANAGEMENT SYSTEM; ESTIMATION PROGRAM; MEASUREMENT DEVICE; METER PLACEMENT; METERING DEVICES; PHASOR MEASUREMENT UNIT; POWER SYSTEM COMMUNICATION; SYSTEM OBSERVABILITY; TEST NETWORK; TOTAL COSTS; TWO SECTION; WIDE AREA MEASUREMENT SYSTEMS;

EID: 84861846408     PISSN: 19493053     EISSN: None     Source Type: Journal    
DOI: 10.1109/TSG.2011.2178080     Document Type: Article
Times cited : (74)

References (27)
  • 1
    • 33751369354 scopus 로고    scopus 로고
    • Mixed measurements state estimation based on wide-areameasurement systemand analysis
    • Dalian, China
    • J. Ding and Z. Cai, "Mixed measurements state estimation based on wide-areameasurement systemand analysis," in Proc. 2005 IEEE/PES Asia Pacific Transm. Distrib. Conf. Exhib., Dalian, China, pp. 1-5.
    • Proc. 2005 IEEE/PES Asia Pacific Transm. Distrib. Conf. Exhib , pp. 1-5
    • Ding, J.1    Cai, Z.2
  • 2
    • 43549115677 scopus 로고    scopus 로고
    • Wide-area protection and control system with WAMS based
    • Chongqing, China, Oct
    • Y. Dengjun, "Wide-area protection and control system with WAMS based," in Proc. Int. Conf. Power Syst. Technol. (PowerCon), Chongqing, China, Oct. 2006, pp. 1-5.
    • (2006) Proc. Int. Conf. Power Syst. Technol. (PowerCon , pp. 1-5
    • Dengjun, Y.1
  • 3
    • 79951959545 scopus 로고    scopus 로고
    • Comparison between communication infrastructures of centralized and decentralized wide area measurement systems
    • Mar
    • M. Shahraeini, M. H. Javidi, and M. S. Ghazizadeh, "Comparison between communication infrastructures of centralized and decentralized wide area measurement systems," IEEE Trans. Smart Grid, vol. 2, no. 1, pp. 206-211, Mar. 2011.
    • (2011) IEEE Trans. Smart Grid , vol.2 , Issue.1 , pp. 206-211
    • Shahraeini, M.1    Javidi, M.H.2    Ghazizadeh, M.S.3
  • 4
    • 42549145870 scopus 로고    scopus 로고
    • Multi-layer disturbance processing system based on multiple information sources
    • Jun
    • T. Bi and Q. Li, "Multi-layer disturbance processing system based on multiple information sources," in Proc. IEEE Power Eng. Soc. Gen. Meet., Jun. 2007, pp. 1-4.
    • (2007) Proc. IEEE Power Eng. Soc. Gen. Meet. , pp. 1-4
    • Bi, T.1    Li, Q.2
  • 5
    • 27744519064 scopus 로고    scopus 로고
    • Power system control centers: Past, present, and future
    • DOI 10.1109/JPROC.2005.857499
    • F. Wu, K. Moslehi, and A. Bose, "Power system control centers: Past, present, and future," Proc. IEEE, vol. 93, no. 11, pp. 1890-1908, Nov. 2005. (Pubitemid 41619230)
    • (2005) Proceedings of the IEEE , vol.93 , Issue.11 , pp. 1890-1908
    • Wu, F.F.1    Moslehi, K.2    Bose, A.3
  • 6
    • 78751497211 scopus 로고    scopus 로고
    • A new approach for classification of data transmission media in power systems
    • Hangzhou, China, Oct. 24-28
    • M. Shahraeini, M. H. Javidi, and M. S. Ghazizadeh, "A new approach for classification of data transmission media in power systems," in Proc. Int. Conf. Power Syst. Technol. (PowerCon), Hangzhou, China, Oct. 24-28, 2010, pp. 1-7.
    • (2010) Proc. Int. Conf. Power Syst. Technol. (PowerCon , pp. 1-7
    • Shahraeini, M.1    Javidi, M.H.2    Ghazizadeh, M.S.3
  • 9
    • 71849091088 scopus 로고    scopus 로고
    • Optimal placement of phasor measurement units for state estimation
    • B. Xu and A. Abur, "Optimal placement of phasor measurement units for state estimation," PSERC, Final Project Rep., 2005.
    • (2005) PSERC, Final Project Rep.
    • Xu, B.1    Abur, A.2
  • 11
    • 79952910208 scopus 로고    scopus 로고
    • Real-time application of synchrophasors for improving reliability
    • Oct
    • "Real-time application of synchrophasors for improving reliability," North American Electric Reliability Corporation (NERC), Oct. 2010.
    • (2010) North American Electric Reliability Corporation (NERC
  • 12
    • 34547885710 scopus 로고    scopus 로고
    • Instrumentation and measurement of a power distribution system laboratory for meter placement and network reconfiguration studies
    • DOI 10.1109/TIM.2007.900420, 23rd Annual IEEE Instrumentation and Measurement Technology Conference (IMTC 2006)
    • V. Cecchi, X. Yang, K. Miu, and C. O. Nwankpa, "Instrumentation and measurement of a power distribution system laboratory for meter placement and network reconfiguration studies," IEEE Trans. Instrum. Meas., vol. 56, no. 4, pp. 1224-1230, Aug. 2007. (Pubitemid 47249884)
    • (2007) IEEE Transactions on Instrumentation and Measurement , vol.56 , Issue.4 , pp. 1224-1230
    • Cecchi, V.1    Yang, X.2    Miu, K.3    Nwankpa, C.O.4
  • 13
    • 0027589817 scopus 로고
    • Power system observability withminimal phasormeasurement placement
    • May
    • T. L. Baldwin, L.Mili,M. B. Boisen, and R. Adapa, "Power system observability withminimal phasormeasurement placement," IEEE Trans. Power Syst., vol. 8, no. 2, pp. 701-715, May 1993.
    • (1993) IEEE Trans. Power Syst. , vol.8 , Issue.2 , pp. 701-715
    • Baldwin, T.L.1    Mili, L.2    Boisen, M.B.3    Adapa, R.4
  • 14
    • 0034186847 scopus 로고    scopus 로고
    • A direct numerical method for observability analysis
    • May
    • B. Gou and A. Abur, "A direct numerical method for observability analysis," IEEE. Trans. Power Syst., vol. 15, no. 2, pp. 625-631, May 2000.
    • (2000) IEEE. Trans. Power Syst. , vol.15 , Issue.2 , pp. 625-631
    • Gou, B.1    Abur, A.2
  • 15
    • 33645532449 scopus 로고    scopus 로고
    • Optimal PMU placement for full network observability using tabu search algorithm
    • May
    • J. N. Peng, Y. Z. Sun, and H. F. Wang, "Optimal PMU placement for full network observability using tabu search algorithm," Int. J. Electr. Power Energy Syst., vol. 28, no. 4, pp. 223-231, May 2006.
    • (2006) Int. J. Electr. Power Energy Syst. , vol.28 , Issue.4 , pp. 223-231
    • Peng, J.N.1    Sun, Y.Z.2    Wang, H.F.3
  • 18
    • 35348860878 scopus 로고    scopus 로고
    • Minimum information loss based state estimation for power systems
    • Montreal, QC, Canada
    • H. Sun, F. Gao, and B. Zhang, "Minimum information loss based state estimation for power systems," in IEEE Power Eng. Soc. Gen. Meet., Montreal, QC, Canada, 2006, pp. 1-10.
    • (2006) IEEE Power Eng. Soc. Gen. Meet. , pp. 1-10
    • Sun, H.1    Gao, F.2    Zhang, B.3
  • 20
    • 74949112107 scopus 로고    scopus 로고
    • Survey on priorities and communication requirements for PMU-based applications in the nordic region
    • Jun
    • M. Chenine, Z. Kun, and L. Nordström, "Survey on priorities and communication requirements for PMU-based applications in the nordic region," in IEEE 2009 Bucharest Power Tech Conf., Jun. 2009, pp. 1-8.
    • (2009) IEEE 2009 Bucharest Power Tech Conf. , pp. 1-8
    • Chenine, M.1    Kun, Z.2    Nordström, L.3
  • 22
    • 79953836220 scopus 로고    scopus 로고
    • A new approach for finding minimum delay control centers of control networks
    • Tehran, Iran, Dec. 4-6
    • M. Shahraeini andM. H. Javidi, "A new approach for finding minimum delay control centers of control networks," in Proc. 5th Int. Symp. Telecommun. (IST), Tehran, Iran, Dec. 4-6, 2010, pp. 938-943.
    • (2010) Proc. 5th Int. Symp. Telecommun. (IST , pp. 938-943
  • 25
    • 0030414339 scopus 로고    scopus 로고
    • A genetic algorithm for network partitioning in power system state estimation
    • S. O. Orero and M. R. Irving, "A genetic algorithm for network partitioning in power system state estimation," in Proc. UKACC Int. Conf. CONTROL '96, pp. 162-165.
    • Proc. UKACC Int. Conf. CONTROL ' , vol.96 , pp. 162-165
    • Orero, S.O.1    Irving, M.R.2
  • 27
    • 84861859935 scopus 로고    scopus 로고
    • [Online]. Available
    • "System test cases archive" [Online]. Available: http://www.ee.washington. edu/research/pstca
    • System Test Cases Archive


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.